ENGLISH
INSTALLATION INSTRUCTIONS
SINGLE SPLIT WALL MOUNTED AIR CONDITIONER
1. Type "A" screw
2. Installation Plate
3. Type "B" screw
4. Holder Remote Control
Air
filter
Installation plate
Sleeve
Bushing-Sleeve
Putty(Gum Type Sealer)
Bend the pipe as closely 
on the wall as possible, 
but be careful that it 
doesn’t break.
Installation parts you 
must purchase 
Vinyl tape (Wide)
¥ Apply after carrying out a
   drainage test.
¥ To carry out the drainage 
   test, remove the air filters
  and pour water into the heat 
  exchanger.
Saddle
Gas side piping       (Optional Parts)
Liquid side piping       (Optional Parts)
Additional drain pipe
Vinyl tape (Narrow)
Connecting cable
(Optional Parts) 
P/No.: 3828A20170Q
(Art Cool Deluxe Series)
• Please read this instruction sheet completely before installing the product.
• When the power cord is damaged, replacement work shall be performed by authorized
personnel only.
• Installation work must be performed in accordance with the national wiring standards by
authorized personnel only.
Installation Parts Provided
• This illustration is for explanation purposes only.
• The indoor unit will actually face a different way.
• Copper lines must be insulated independently.
êìëëääàâ
10
Connection of the
pipes-Outdoor
Align the center of the pipings and
sufficiently tighten the flare nut by hand.
Finally, tighten the flare nut with torque
wrench until the wrench clicks.
When tightening the flare nut with torque
wrench, ensure the direction for tightening
follows the arrow on the wrench.
A
B
Outdoor unit 
Gas side piping
(Bigger diameter)
Liquid side
piping
(Smaller
diameter)
Torque wrench
mm
inch
kg.m
Ø6.35
1/4
1.8
Ø9.52
3/8
4.2
Ø12.7
1/2
5.5
Ø15.88
5/8
6.6
Ø19.05
3/4
6.6
Outside diameter
Torque
• Bad case
■ 
Following bending type from right to left could
cause problem of pipe damage.
CAUTION
ENGLISH
11
Connect the cable to the Indoor unit.
Connect the cable to the indoor unit by connecting the wires to the terminals on the control board
individually according to the outdoor unit connection. 
(Ensure that the color of the wires of the outdoor
unit and the terminal No. are the same as those of the indoor unit.)
The earth wire should be longer than the common wires.
The above circuit diagram is subject to change without notice.
When installing, refer to the circuit diagram on the control box inside Indoor Uint.
CONNECTING THE CABLE BETWEEN INDOOR UNIT AND OUTDOOR UNIT
Air 
Conditioner
Main power source
If a power plug is not to be used, provide a circuit breaker
between power source and the unit as shown below.
Circuit Breaker
Use a circuit
breaker or time
delay fuse.
CAUTION
• The above circuit diagram is subject to change
without notice. 
• Be sure to connect wires according to the wiring
diagram.
• Connect the wires firmly, so that not to be pulled
out easily.
• Connect the wires according to color codes by
referring the wiring diagram.
CAUTION
The power cord connected to the "A" unit should be
complied with the following specifications
(Type "B" approved by HAR or SAA).
• When installing, refer to the circuit diagram on the
Control Box of Indoor Unit.
• When installing, refer to the wiring diagram on the
Control Cover Inside Outdoor Unit.
7k~14k
1.0
Cable Type(B)
H07RN-F
NORMAL CROSS
-SECTIONAL AREA
Grade
(mm
2
)
(mm
2
)
The power connecting cable connected to the indoor
and outdoor unit should be complied with the following
specifications
(Type "B" approved by HAR or SAA).
NORMAL
CROSS-SECTIONAL
AREA 0.75mm
2
 
CAUTION
5k~9k
12k~14K
0.75
1.0
Unit(A)
Indoor
Indoor
Cable Type(B)
H05VV-F
H05VV-F
NORMAL CROSS
-SECTIONAL AREA
Grade
12
Connect the cable to the
outdoor unit
Remove the control cover from the unit by
loosening the screw.
Connect the wires to the terminals on the
control board individually.
Secure the cable onto the control board with
the cord clamp.
Refix the control cover to the original
position with the screw.
Use a recognized circuit breaker 
"A" 
between the power source and the unit. 
A disconnecting device to adequately
disconnect all supply lines must be fitted.
A
B
C
D
Terminal block
Over 5mm
Cover control
Connecting cable
Connecting cable
After the confirmation of the above conditions, prepare the wiring as follows:
1) Never fail to have an individual power circuit specifically for the air conditioner. As for
the method of wiring, be guided by the circuit diagram posted on the inside of control
cover.
2) The screw which fasten the wiring in the casing of electrical fittings are liable to come
loose from vibrations to which the unit is subjected during the course of
transportation. Check them and make sure that they are all tightly fastened. (If they
are loose, it could cause burn-out of the wires.)
3) Specification of power source.
4) Confirm that electrical capacity is sufficient.
5) See to that the starting voltage is maintained at more than 90 percent of the rated
voltage marked on the name plate.
6) Confirm that the cable thickness is as specified in the power source specification.
(Particularly note the relation between cable length and thickness. (Refer to page 11))
7) Always install an earth leakage circuit breaker in a wet or moist area.
8) The following would be caused by voltage drop.
• Vibration of a magnetic switch, which will damage the contact point, fuse breaking, disturbance of the
normal function of the overload.
9) The means for disconnection from a power supply shall be incorporated in the fixed
wiring and have an air gap contact separation of at least 3mm in each active(phase)
conductors.
Outdoor Unit
7k~14k
15
Circuit Breaker
(A)
Grade
CAUTION
Page of 127