JBL MA6002 EMC - CB Certificate ▷ View online
File
No.
F30132-00-00HM
, page 13 of 20
mikes-testingpartners gmbh
x Tel.:09424-94810 x Fax:09424-9481240
Rev. Nr. 1.0
5.4
Electrostatic discharge
For test instruments and accessories used see section 6 Part I 2.
5.4.1
Description of the test location
Test location:
Shielded Room S3
5.4.2
Photo documentation of the test set-up
5.4.3
Legend C: Contact discharge A: Air discharge
C
File
No.
F30132-00-00HM
, page 14 of 20
mikes-testingpartners gmbh
x Tel.:09424-94810 x Fax:09424-9481240
Rev. Nr. 1.0
Test specification:
Contact discharge voltage:
2 kV
/
4 kV
Air discharge voltage:
2 kV
/
4 kV
/
8 kV
Discharge impedance:
330
Ω / 150 pF
Discharge factor:
≥ 1 sec.
Number of discharges:
≥ 10
Type of discharge:
Direct discharge:
- Contact discharge
- Air discharge
Indirect discharge:
- Contact discharge
Polarity:
- positive
- negative
Discharge location:
- all external locations accessible by hand
- see photo documentation of the test set-up
- horizontal plate (HCP)
- vertical coupling plate (VCP)
- see photo documentation of the test set-up
- horizontal plate (HCP)
- vertical coupling plate (VCP)
5.4.4 Test
result
The requirements are FULFILLED.
Performance Criterion:
B
Remarks:
During electrostatic discharge the sine wave was disturbed.
Operation mode: 1 kHz 1/8 power.
File
No.
F30132-00-00HM
, page 15 of 20
mikes-testingpartners gmbh
x Tel.:09424-94810 x Fax:09424-9481240
Rev. Nr. 1.0
5.5 Radiated,
radio-frequency, electromagnetic field
For test instruments and accessories used see section 6 Part I 3.
5.5.1
Description of the test location
Test location:
Anechoic Chamber A2
5.5.2
Photo documentation of the test set-up
5.5.3 Test
specification:
Frequency range:
900 MHz Pulse modulation
Field strength: 3
V/m
EuT - antenna distance: 3
m
Modulation:
PM / square wave: 217 Hz / duty cycle: 12.5 %
Antenna polarisation: -
vertical
5.5.4 Test
result
The requirements are FULFILLED.
Performance Criterion:
A
Remarks:
Operation mode: 1 kHz audio signal.
File
No.
F30132-00-00HM
, page 16 of 20
mikes-testingpartners gmbh
x Tel.:09424-94810 x Fax:09424-9481240
Rev. Nr. 1.0
6 U S E D T E S T E Q U I P M E N T A N D A C C E S S O R I E S
All test instruments used, in addition to the test accessories, are calibrated and verified regularly.
Test ID
Model / Type
Kind of Equipment
Manufacturer
Equipment No.
A 7
ESCS 30
Test Receiver
Rohde & Schwarz München
02-02/03-05-001
MDS 21
Absorbing Clamp
Rohde & Schwarz München
02-02/22-05-015
HCA 1008.8420.02
Absorbing Clamp Slideway Rohde & Schwarz München
02-02/50-05-046
I 2
NSG 435
ESD Generator
Schaffner Elektrotest GmbH
02-02/09-05-002
THL-313
Thermo-Hygrometer
PTL Dr. Grabenhorst GmbH
02-02/15-05-001
I 3
SME 03
Signal Generator
Rohde & Schwarz München
02-02/05-05-010
LMV-1817
Noise Meter
Leader
02-02/07-05-028
500W1000A
RF Amplifier
Amplifier Research
02-02/17-05-010
CBL6144
Bilog Antenna
Schaffner Elektrotest GmbH
02-02/24-05-010
N-2000-N
RF Cable
mikes-testingpartners gmbh
02-02/50-05-108
7/16-6000-7/16
RF Cable
Rosenberger HF-Technik
02-02/50-05-109
S 2
SML 01
Signal Generator
Rohde & Schwarz München
02-02/05-05-005
6000N
RF Amplifier
PMM
02-02/17-05-002
UPL
Audio Analyzer
Rohde & Schwarz München
02-02/19-05-001
MSF
Mains Filter
Erika Fiedler Messtechnik
02-02/22-05-024
RCo 8 Ohm
RC Network
Erika Fiedler Messtechnik
02-02/22-05-025
RCo 22kOhm
RC Network
Erika Fiedler Messtechnik
02-02/22-05-027
RCi 47kOhm
RC Network
Erika Fiedler Messtechnik
02-02/22-05-029
PSU
RF Relaismatrix
Rohde & Schwarz München
02-02/50-05-002
JFW 50FHC-006-25
RF Attenuator 6 dB / 25 W jfw
02-02/50-05-020
S 3
SML 01
Signal Generator
Rohde & Schwarz München
02-02/05-05-005
6000N
RF Amplifier
PMM
02-02/17-05-002
UPL
Audio Analyzer
Rohde & Schwarz München
02-02/19-05-001
Open Strip Line
Open Strip Line
Natural Audio Lautsprecher
02-02/24-05-011
PSU
RF Relaismatrix
Rohde & Schwarz München
02-02/50-05-002
Mains Stop Filter S3
Mains Stop Filter S3
Erika Fiedler Messtechnik
02-02/50-05-017
LBS
Band-Stop-Filter
Erika Fiedler Messtechnik
02-02/50-05-018