DOWNLOAD JBL MA6002 Service Manual ↓ Size: 1.93 MB | Pages: 29 in PDF or view online for FREE

Model
MA6002
Pages
29
Size
1.93 MB
Type
PDF
Document
EMC - CB Certificate
Brand
Device
Car Audio
File
ma6002.pdf
Date

JBL MA6002 EMC - CB Certificate ▷ View online

 
 
File No. 
F30132-00-00HM
, page 5 of 20 
 
mikes-testingpartners gmbh 
x Tel.:09424-94810 x Fax:09424-9481240 
Rev. Nr. 1.0 
3   E Q U I P M E N T  U N D E R  T E S T  
3.1 
Photo documentation of the EuT 
 
 
 
 
 
 
 
 
 
 
File No. 
F30132-00-00HM
, page 6 of 20 
 
mikes-testingpartners gmbh 
x Tel.:09424-94810 x Fax:09424-9481240 
Rev. Nr. 1.0 
3.2 
Power supply system utilised 
 
Power supply voltage 
:  12-14 V / DC 
 
3.3 
Short description of the Equipment under Test (EuT) 
 
Car amplifier used for reproduction of audio information’s. 
  
 
Number of tested samples: 
Serial number: 
PP001 
 
Feature list: 
 
 - Single scart 
 - Headphone socket 
 - Audio input 
 - Double scart 
 - Front/side A/V input 
 - Audio output 
 - Triple scart 
 - Speaker output 
 - PiP module 
 - Teletext 
 - 50 Hz 
 - 100 Hz 
 - Double tuner 
 - PC in/out 
 - Mono 
 - Stereo 
 -                
 
 
Essential Performance of the EuT based on customer definition: 
 
 
 
 
EuT operation mode:  
 
 
The equipment under test was operated during the measurement under the following conditions: 
 
 
- 1 kHz audio signal 
- 1 kHz 1/8 power 
 
 
EuT configuration: 
(The CDF filled by the applicant can be viewed at the test laboratory.) 
 
The following peripheral devices and interface cables were connected during the measurements: 
 
-  power supply 
Model : Statron Typ 2232 
 
-  scopemeter 
Model : Fluke 123 
 
-  NF-generator 
Model :  Fischer SINOISE - 1 
 
- unscreened power cables 
 
- customer specific cables 
 
 
 
File No. 
F30132-00-00HM
, page 7 of 20 
 
mikes-testingpartners gmbh 
x Tel.:09424-94810 x Fax:09424-9481240 
Rev. Nr. 1.0 
3.4 Performance 
level 
 
The test results shall be classified in terms of the loss of function or degradation of performance of the equipment 
under test, relative to a performance level defined by its manufacturer or the requestor of the test, or agreed 
between the manufacturer and the purchaser of the product. 
 
Definition related to the performance level: 
 
 
 
based on the used product standard 
 
 
based on the declaration of the manufacturer, requestor or purchaser 
 
Criterion A:  
Definition: normal performance within limits specified by the manufacturer, requestor or purchaser: 
 
The equipment shall continue to operate as intended during the test. No change of actual operating state (for 
example change of channel) is allowed as a result of the application of the test. The criterion of compliance with 
the requirement is a wanted to unwanted audio signal ratio of 
≥ 26 dB at a wanted audio signal level of 500 mW, 
or at another audio signal level specified by the manufacturer. No degradation of test picture is allowed. 
 
Criterion B:  
Definition: temporary loss of function or degradation of performance which ceases after the disturbance ceases, and from which the equipment 
under test recovers its normal performance, without operator intervention: 
 
After the test, the equipment shall continue to operate as intended without operator intervention. No loss of  
function is allowed after the test when the apparatus is used as intended, but failures which are recovered  
automatically but which cause temporary delay in processing, are permissible. No change of actual operating state
is allowed as a result of the application of the test. During the test, degradation of performance is allowed. 
 
Criterion C:  
Definition: temporary loss of function or degradation of performance, the correction of which requires operator intervention: 
 
 
 
 
 
 
 
File No. 
F30132-00-00HM
, page 8 of 20 
 
mikes-testingpartners gmbh 
x Tel.:09424-94810 x Fax:09424-9481240 
Rev. Nr. 1.0 
4   T E S T  E N V I R O N M E N T  
4.1 
Address of the test laboratory 
 
mikes-testingpartners gmbh 
 Ohmstrasse 
2-4 
 94342 
Strasskirchen 
 Deutschland 
 
 
 
 
4.2 Environmental 
conditions 
 
During the measurement the environmental conditions were within the listed ranges: 
 
Temperature: 
15-35 ° C 
 
 
 
 
Humidity: 30-60 
 
 
 
 
Atmospheric pressure: 
86-106 kPa 
 
 
 
 
4.3 
Statement of the measurement uncertainty 
 
The data and results referenced in this document are true and accurate. The reader is cautioned that there may 
be errors within the calibration limits of the equipment and facilities. The measurement uncertainty was calculated 
for all measurements listed in this test report acc. to CISPR 16-4-2 /11.2003 „Uncertainties, statistics and limit 
modelling – Uncertainty in EMC measurements“ and is documented in the quality system acc. to DIN EN ISO/IEC 
17025. Furthermore, component and process variability of devices similar to that tested may result in additional 
deviation. The manufacturer has the sole responsibility of continued compliance of the device. 
 
  
 
Page of 29
Display

Click on the first or last page to see other MA6002 service manuals if exist.