Page 8 of 10 
 
 
File No.: E042R-016 
It should not be reproduced except in full, without the written approval of ONETECH. 
EMC-007 (Rev.0)
 
HEAD OFFICE 
: #505 SK APT. Factory 223-28, Sangdaewon 1 Dong, Jungwon-Gu, Seongnam-City, Gyunggi-Do, 462-121, Korea  
  
(TEL: 
+82-31-746-8500, FAX: +82-31-746-8700
)
 
EMC Testing Dept : 
426-1 
Daessangryung-Ri, Chowol-Myun, Gwangju-City, Gyunggi-Do 464-860 Korea. (TEL: +82-31-765-8289, FAX: +82-31-766-2904)
 
ONETECH
Testing & Evaluation Lab. 
 
- Coupling Location 
: AUX Output L-CH 
Freq. Reading[dBuV] Insert 
Cable  Total[dB(pW)] 
LIMIT[dB(pW)] 
[MHz] [Q.P]  [AVE] Loss  Loss  [Q.P]  [AVE] 
[Q.P] 
[AVE] 
31.10  
39.40  
30.20  
1.37  
0.98  
41.75  
32.55  
45.04  
35.04  
50.30  
35.60  
26.10  
0.30  
1.01  
36.91  
27.41  
45.75  
35.75  
70.50  
31.70  
-0.30  
1.21  
32.61  
46.50  
36.50  
83.70  
28.30  
-0.49  
1.20  
29.01  
46.99  
36.99  
123.20  
29.40  
-1.20  
1.06  
29.26  
48.45  
38.45  
 
- Coupling Location 
: AUX Output R-CH 
Freq. Reading[dBuV] Insert 
Cable  Total[dB(pW)] 
LIMIT[dB(pW)] 
[MHz] [Q.P]  [AVE] Loss  Loss  [Q.P]  [AVE] 
[Q.P] 
[AVE] 
31.10  
34.60  
25.10  
1.37  
0.98  
36.95  
27.45  
45.04  
35.04  
50.00  
34.20  
25.90  
0.30  
1.00  
35.50  
27.20  
45.74  
35.74  
70.50  
32.30  
-0.30  
1.21  
33.21  
46.50  
36.50  
83.50  
27.90  
-0.49  
1.20  
28.61  
46.98  
36.98  
 
- Coupling Location 
: Plus(+) Cable 
Freq. Reading[dBuV] Insert 
Cable  Total[dB(pW)] 
LIMIT[dB(pW)] 
[MHz] [Q.P]  [AVE] Loss  Loss  [Q.P]  [AVE] 
[Q.P] 
[AVE] 
30.00  
39.20  
30.30  
1.30  
1.00  
41.50  
32.60  
45.00  
35.00  
48.10  
30.20  
0.58  
1.08  
31.86  
45.67  
35.67  
66.70  
31.40  
0.09  
1.20  
32.69  
46.36  
36.36  
71.30  
31.70  
-0.30  
1.23  
32.63  
46.53  
36.53  
82.60  
28.20  
-0.49  
1.20  
28.91  
46.95  
36.95  
 
 
Page 9 of 10 
 
 
File No.: E042R-016 
It should not be reproduced except in full, without the written approval of ONETECH. 
EMC-007 (Rev.0)
 
HEAD OFFICE 
: #505 SK APT. Factory 223-28, Sangdaewon 1 Dong, Jungwon-Gu, Seongnam-City, Gyunggi-Do, 462-121, Korea  
  
(TEL: 
+82-31-746-8500, FAX: +82-31-746-8700
)
 
EMC Testing Dept : 
426-1 
Daessangryung-Ri, Chowol-Myun, Gwangju-City, Gyunggi-Do 464-860 Korea. (TEL: +82-31-765-8289, FAX: +82-31-766-2904)
 
ONETECH
Testing & Evaluation Lab. 
 
- Coupling Location 
: Minus(-) Cable 
Freq. Reading[dBuV] Insert 
Cable  Total[dB(pW)] 
LIMIT[dB(pW)] 
[MHz] [Q.P]  [AVE] Loss  Loss  [Q.P]  [AVE] 
[Q.P] 
[AVE] 
30.10  
38.30  
29.10  
1.31  
1.00  
40.61  
31.41  
45.00  
35.00  
34.90  
35.70  
26.90  
1.59  
0.90  
38.19  
29.39  
45.18  
35.18  
54.00  
28.90  
0.29  
1.16  
30.35  
45.89  
35.89  
60.50  
30.70  
-0.40  
1.20  
31.50  
46.13  
36.13  
69.70  
30.80  
0.07  
1.20  
32.07  
46.47  
36.47  
83.20  
27.30  
-0.49  
1.20  
28.01  
46.97  
36.97  
 
- Coupling Location 
: Remote Cable 
Freq. Reading[dBuV] Insert 
Cable  Total[dB(pW)] 
LIMIT[dB(pW)] 
[MHz] [Q.P]  [AVE] Loss  Loss  [Q.P]  [AVE] 
[Q.P] 
[AVE] 
30.30  
33.90  
24.10  
1.32  
0.99  
36.21  
26.41  
45.01  
35.01  
50.00  
32.20  
0.30  
1.00  
33.50  
45.74  
35.74  
68.60  
34.40  
25.80  
0.08  
1.20  
35.68  
27.08  
46.43  
36.43  
 
- Coupling Location 
: Remote Level Control Cable 
Freq. Reading[dBuV] Insert 
Cable  Total[dB(pW)] 
LIMIT[dB(pW)] 
[MHz] [Q.P]  [AVE] Loss  Loss  [Q.P]  [AVE] 
[Q.P] 
[AVE] 
30.30  
34.10  
24.60  
1.32  
0.99  
36.41  
26.91  
45.01  
35.01  
50.00  
35.60  
25.80  
0.30  
1.00  
36.90  
27.10  
45.74  
35.74  
54.00  
34.70  
25.20  
0.29  
1.16  
36.15  
26.65  
45.89  
35.89  
66.50  
33.00  
0.09  
1.20  
34.29  
46.35  
36.35  
96.70  
28.60  
-1.00  
1.27  
28.87  
47.47  
37.47  
Note:   Q.P : Quasi-peak, AVE : Average 
 
Q.P Limit [dB(pW)]: Freq.(MHz) / 27 + 43.89 
A.V Limit [dB(pw)]: Freq.(MHz) / 27 + 33.89 
In case that Quasi-Peak values are under the Average limit, Average data are not recorded. 
 
 
 
                                                                             
 
Tested by: Eung-Chan, Kim / Test Engineer 
 
Page 10 of 10 
 
 
File No.: E042R-016 
It should not be reproduced except in full, without the written approval of ONETECH. 
EMC-007 (Rev.0)
 
HEAD OFFICE 
: #505 SK APT. Factory 223-28, Sangdaewon 1 Dong, Jungwon-Gu, Seongnam-City, Gyunggi-Do, 462-121, Korea  
  
(TEL: 
+82-31-746-8500, FAX: +82-31-746-8700
)
 
EMC Testing Dept : 
426-1 
Daessangryung-Ri, Chowol-Myun, Gwangju-City, Gyunggi-Do 464-860 Korea. (TEL: +82-31-765-8289, FAX: +82-31-766-2904)
 
ONETECH
Testing & Evaluation Lab. 
APPENDIX I - TEST SET-UP PHOTO: (Disturbance Radiation Test) 
 
 
 
Page 1 of 17 
 
 
File No.: E042R-017 
It should not be reproduced except in full, without the written approval of ONETECH. 
EMC-008 (Rev.0)
 
HEAD OFFICE 
: #505 SK APT. Factory 223-28, Sangdaewon 1 Dong, Jungwon-Gu, Seongnam-City, Gyunggi-Do, 462-121, Korea  
  
(TEL: 
+82-31-746-8500, FAX: +82-31-746-8700
)
 
EMC Testing Dept : 
426-1 
Daessangryung-Ri, Chowol-Myun, Gwangju-City, Gyunggi-Do 464-860 Korea. (TEL: +82-31-765-8289, FAX: +82-31-766-2904)
 
ONETECH
Testing & Evaluation Lab. 
 
 
 
IMMUNITY TEST REPORT 
 
 
Test report file number   
: E042R-017 
Applicant 
: Harman Consumer Group. 
Address 
: New York 250 Crossways Park West Woodbury, NY 11797, USA 
Manufacturer 
: Chunglam Digital Co., Ltd. 
Address 
: #453-4, Yongduri, Gongdo-Eup, Ansung-Si, Kyunggi-Do, 456-821, Korea 
Type of Equipment   
: Automotive Power Boost Amplifier 
Model Name. : 
GTO 601.1 
Multiple Model Name. 
: N/A 
Serial number 
: N/A 
Total page of Report 
: 17 pages (including this page)   
Date of Incoming 
: January 08, 2004 
Date of Issuing   
: February 04, 2004 
 
 
SUMMARY 
The equipment complies with the standards; EN55 020: 1994 + A11: 96 + A12: 99 + A13: 99 and A14: 99. 
This test report only contains the result of a single test of the sample supplied for the examination. 
It is not a general valid assessment of the features of the respective products of the mass-production. 
 
 
 
 
Prepared by: 
 Reviewed 
by: 
 
 
Young-Min, Choi/ Project Engineer 
 
Gea-Won, Lee / Chief Engineer 
 
EMC Div. 
EMC Div. 
 
ONETECH Corp.   
ONETECH Corp. 
SEMKO Approved Laboratory
 