DOWNLOAD JBL GTO 601.1 (serv.man12) Service Manual ↓ Size: 930.84 KB | Pages: 28 in PDF or view online for FREE

Model
GTO 601.1 (serv.man12)
Pages
28
Size
930.84 KB
Type
PDF
Document
EMC - CB Certificate
Brand
Device
Car Audio
File
gto-6011-sm12.pdf
Date

JBL GTO 601.1 (serv.man12) EMC - CB Certificate ▷ View online

 
Page 4 of 10 
 
 
File No.: E042R-016 
It should not be reproduced except in full, without the written approval of ONETECH. 
EMC-007 (Rev.0)
 
HEAD OFFICE 
: #505 SK APT. Factory 223-28, Sangdaewon 1 Dong, Jungwon-Gu, Seongnam-City, Gyunggi-Do, 462-121, Korea  
  
(TEL: 
+82-31-746-8500, FAX: +82-31-746-8700
)
 
EMC Testing Dept : 
426-1 
Daessangryung-Ri, Chowol-Myun, Gwangju-City, Gyunggi-Do 464-860 Korea. (TEL: +82-31-765-8289, FAX: +82-31-766-2904)
 
ONETECH
Testing & Evaluation Lab. 
3. EUT (Equipment Under Test) 
3.1 Identification of EUT 
-. Equipment   
: Automotive Power Boost Amplifier 
-. Type/model   
: GTO 601.1 
-. Brand Name 
: JBL 
-. Serial number 
: N/A 
-. Electrical Rating 
: DC 14.4V from battery of Car 
-. Manufacturer 
: Chunglam Digital Co., Ltd. 
3.2 Additional information about the EUT 
The Harman Consumer Group., Model GTO 601.1 (referred to as the EUT in this report) is an Automotive Power Boost 
Amplifier that is installed in the car. Product specification described herein was obtained from product data sheet or user’s 
manual. 
CHASSIS TYPE 
Metal 
LIST OF EACH OSC. OR 
CRY. FREQ.(FREQ.>=1MHz) 
None 
NUMBER OF LAYERS 
2 Layers 
AUDIO POWER OUTPUT 
4ohms: 300W x 1, 2ohms: 600W x 1
 
EXTERNAL TERMINALS 
Audio Input (L/R), Audio Output (L/R), Aux Output (L/R), 
Plus(+), Minus(-), Remote, Remote Level Control 
3.3 Peripheral equipment 
Defined as equipment needed for correct operation of the EUT, but not considered as tested:   
Model Manufacturer 
Description  Connected 
to
GTO 601.1 
Chunglam Digital Co., Ltd. 
Automotive Power Boost Amplifier(EUT) 
N/A 
CS-5270 Kenwood 
Oscilloscope  EUT 
Output 
AG-203D 
Kenwood 
Audio Generator 
EUT Input 
N/A 
N/A 
4 ohm Load 
EUT Output 
 
Page 5 of 10 
 
 
File No.: E042R-016 
It should not be reproduced except in full, without the written approval of ONETECH. 
EMC-007 (Rev.0)
 
HEAD OFFICE 
: #505 SK APT. Factory 223-28, Sangdaewon 1 Dong, Jungwon-Gu, Seongnam-City, Gyunggi-Do, 462-121, Korea  
  
(TEL: 
+82-31-746-8500, FAX: +82-31-746-8700
)
 
EMC Testing Dept : 
426-1 
Daessangryung-Ri, Chowol-Myun, Gwangju-City, Gyunggi-Do 464-860 Korea. (TEL: +82-31-765-8289, FAX: +82-31-766-2904)
 
ONETECH
Testing & Evaluation Lab. 
3.4 Mode of operation during the test   
-. Practice operation - Input: 100Hz sine wave, Output: 1/8 max power. 
3.5 Alternative type(s)/model(s); also covered by this test report. 
-. The difference(s) compared to the EUT is/are: none 
4. EUT MODIFICATIONS 
-. None 
 
Page 6 of 10 
 
 
File No.: E042R-016 
It should not be reproduced except in full, without the written approval of ONETECH. 
EMC-007 (Rev.0)
 
HEAD OFFICE 
: #505 SK APT. Factory 223-28, Sangdaewon 1 Dong, Jungwon-Gu, Seongnam-City, Gyunggi-Do, 462-121, Korea  
  
(TEL: 
+82-31-746-8500, FAX: +82-31-746-8700
)
 
EMC Testing Dept : 
426-1 
Daessangryung-Ri, Chowol-Myun, Gwangju-City, Gyunggi-Do 464-860 Korea. (TEL: +82-31-765-8289, FAX: +82-31-766-2904)
 
ONETECH
Testing & Evaluation Lab. 
5. DISTURBANCE POWER 
5.1 Operating environment 
Temperature  
20 °C 
Relative humidity 
48 % 
5.2 Test set-up 
The EUT was placed on a non-metallic table of height 0.8m. At the side of the EUT a non-metallic table of length 6m was 
placed to provide for movement of the absorbing clamp. The absorbing clamp was applied successively to all leads whose 
length was 25cm or longer, unscreened and screened. For each read the maximum measured value at each frequency which 
was obtained when the absorbing clamp is moved along the lead the distance specified is to be registered. No metallic 
object, including a possible other unit than 0.8m. 
All screened and unscreened cables were measured with an absorbing clamp, according EN 55013- 5.6. 
The test set-up photo is included in appendix I. 
5.3 Measurement uncertainty 
Disturbance power, quasi-peak detection 
: ± 3.1dB 
Disturbance power, average detection 
: ± 3.1dB 
The measurement uncertainty describes the overall uncertainty of the given measured value during operation of EUT in the 
above-mentioned way. 
5.4 Test equipment used   
 
Model Number 
Manufacturer 
Description 
Serial Number 
„ -  ESVS10 
Rohde & Schwarz 
EMI Test Receiver 
827864/005 
„ -  8591A 
Hewlett Packard 
Spectrum Analyzer 
3131A02312 
„ -  MDS-21 
Rohde & Schwarz   
Absorbing Clamp 
842291/007 
All test equipment used is calibrated on a regular basis. 
 
 
Page 7 of 10 
 
 
File No.: E042R-016 
It should not be reproduced except in full, without the written approval of ONETECH. 
EMC-007 (Rev.0)
 
HEAD OFFICE 
: #505 SK APT. Factory 223-28, Sangdaewon 1 Dong, Jungwon-Gu, Seongnam-City, Gyunggi-Do, 462-121, Korea  
  
(TEL: 
+82-31-746-8500, FAX: +82-31-746-8700
)
 
EMC Testing Dept : 
426-1 
Daessangryung-Ri, Chowol-Myun, Gwangju-City, Gyunggi-Do 464-860 Korea. (TEL: +82-31-765-8289, FAX: +82-31-766-2904)
 
ONETECH
Testing & Evaluation Lab. 
5.5 Test data 
-. Test Date 
: January 09, 2003 
-. Resolution bandwidth  : 120kHz 
-. Frequency range 
: 30MHz ~ 300MHz 
- Coupling Location 
: Input L-CH 
Freq. Reading[dBuV] Insert 
Cable  Total[dB(pW)] 
LIMIT[dB(pW)] 
[MHz] [Q.P]  [AVE] Loss  Loss  [Q.P]  [AVE] 
[Q.P] 
[AVE] 
34.30  
36.50  
26.10  
1.56  
0.91  
38.97  
28.57  
45.16  
35.16  
49.20  
34.10  
25.40  
0.58  
1.03  
35.71  
27.01  
45.71  
35.71  
69.20  
34.20  
29.80  
0.08  
1.20  
35.48  
31.08  
46.45  
36.45  
125.00  
29.80  
-1.00  
1.10  
29.90  
48.52  
38.52  
 
- Coupling Location 
: Input R-CH 
Freq. Reading[dBuV] Insert 
Cable  Total[dB(pW)] 
LIMIT[dB(pW)] 
[MHz] [Q.P]  [AVE] Loss  Loss  [Q.P]  [AVE] 
[Q.P] 
[AVE] 
35.10  
33.20  
24.40  
3.69  
0.91  
37.80  
29.00  
45.19  
35.19  
54.60  
30.60  
0.28  
1.18  
32.06  
45.91  
35.91  
69.40  
34.90  
26.40  
0.08  
1.20  
36.18  
27.68  
46.46  
36.46  
96.70  
25.20  
-1.00  
1.27  
25.47  
47.47  
37.47  
 
- Coupling Location 
: Output L-CH 
Freq. Reading[dBuV] Insert 
Cable  Total[dB(pW)] 
LIMIT[dB(pW)] 
[MHz] [Q.P]  [AVE] Loss  Loss  [Q.P]  [AVE] 
[Q.P] 
[AVE] 
31.10  
37.40  
28.10  
1.37  
0.98  
39.75  
30.45  
45.04  
35.04  
50.00  
34.40  
25.90  
0.30  
1.00  
35.70  
27.20  
45.74  
35.74  
67.50  
34.80  
25.30  
0.09  
1.20  
36.09  
26.59  
46.39  
36.39  
 
 
- Coupling Location 
: Output R-CH 
Freq. Reading[dBuV] Insert 
Cable  Total[dB(pW)] 
LIMIT[dB(pW)] 
[MHz] [Q.P]  [AVE] Loss  Loss  [Q.P]  [AVE] 
[Q.P] 
[AVE] 
30.80  
37.10  
28.40  
1.35  
0.98  
39.43  
30.73  
45.03  
35.03  
50.80  
30.20  
0.30  
1.03  
31.53  
45.77  
35.77  
56.70  
32.00  
0.09  
1.20  
33.29  
45.99  
35.99  
69.40  
32.60  
0.08  
1.20  
33.88  
46.46  
36.46  
Page of 28