DOWNLOAD JBL SUB 180 Service Manual ↓ Size: 1.97 MB | Pages: 44 in PDF or view online for FREE

Model
SUB 180
Pages
44
Size
1.97 MB
Type
PDF
Document
EMC - CB Certificate
Brand
Device
Audio
File
sub-180.pdf
Date

JBL SUB 180 EMC - CB Certificate ▷ View online

 
 
page 21 of 28 
Ref.No.: 410586 
IEC 60065 
Cl. 
Requirement - Test 
Result - Remark 
Verdict 
 
 
TRF No.: I60065__C 
 
 
Winding temperature rise measurements 
 
Ambient temperature t1 (ºC)  ................................. : 25 
 
 
Ambient temperature t2 (
°C) ................................. : 21 
 
temperature rise dT of winding: 
R
1
 (
Ω) 
R
2
 (
Ω) 
dT (K) 
permitted 
dT (K) 
insulation 
class 
Transformer Primary winding 
11.103 
11.710 
18 
85 
Transformer Secondary winding red-red 
1.2834 1.3490  17 
85 
 
 
 
7.2 
TABLE: softening temperature of thermoplastics 
temperature T of part 
T – normal  
conditions (ºC) 
T – fault  
conditions (ºC) 
T softening 
(ºC) 
Mains fuse-holder (required softening temp.150ºC)
-- 
-- 
211 
 
 
 
 
 
 
10.3 
TABLE: insulation resistance measurements 
insulation resistance R between: 
R (M
Ω) 
required R (M
Ω) 
Between the poles of the circuit directly connected to the 
supply mains. 
>10 2 
Reinforced insulation. 
>10 
 
 
10.3 
TABLE: electric strength measurements 
test voltage applied between: 
test voltage (V) 
Breakdown 
Between the poles of the circuit directly connected to the 
supply mains. 
2120V peak 
No 
Reinforced insulation. 
4240V peak 
No 
 
 
 
 
page 22 of 28 
Ref.No.: 410586 
IEC 60065 
Cl. 
Requirement - Test 
Result - Remark 
Verdict 
 
 
TRF No.: I60065__C 
 
11.2 
TABLE: summary of fault condition tests 
 
Voltage (V) 0.9 or 1.06 times rated voltage  .......... : 220-240 
 
 
Ambient temperature (
°C) ..................................... : 22-25 
 
 
Winding temperature rise measurements 
 
 
Ambient temperature t1 (ºC)  ................................. : - 
 
 
Ambient temperature t2 (ºC)  ................................. : - 
 
No
Component 
No. 
Fault 
Test voltage 
 (V) 
Test  
time 
Fuse No.
Fuse  
current 
(A) 
Result 
Speaker 
out. 
 
90% 254.4  4h  - 
Pn=120W    In=0.6A 
T501 (windings max)=69K, 
Enclosure (metallic)=25K, 
PCB/heat sink=<44K 
No hazard. 
Speaker 
sc 
254.4 
30min 
Pn=9W  In=0.067A 
Shutdown. No hazard. 
C501 
sc 
198/254.4 
<2s 
F501 opens immediately. 
No hazard. 
Q301 c-e 
sc 
254.4 
30min 
Pn=15W  In=0.1A 
No high temperatures and no 
hazard. 
Q302 c-e 
sc 
254.4 
30min 
Pn=15W  In=0.1A 
No high temperatures and no 
hazard. 
Q111 c-e 
sc 
254.4 
30min 
Pn=9W  In=0.067A 
Shutdown. No hazard. 
7 PW150D 
V+ to 
AGND 
sc 
198/254.4 
<2s 
F501 opens immediately. 
No hazard. 
8 PW150D 
V- to 
AGND 
sc 
198/254.4 
<2s 
F501 opens immediately. 
No hazard. 
 
 
 
page 23 of 28 
Ref.No.: 410586 
IEC 60065 
Cl. 
Requirement - Test 
Result - Remark 
Verdict 
 
 
TRF No.: I60065__C 
 
14 
TABLE: list of critical components and materials 
Object/part No. 
Manufacturer/ 
trademark 
Type/model 
Technical data 
Standard 
Mark(s) of 
conformity 
Transformer 
T501 
Shanghai 
Transtec 
TT0900101020 
50Hz  230V 
IEC 60065 
Tested in the 
appliance 
Thermal release 
 
Joint Force 
M33 
130
°C 2A 250V
IEC 60691 
VDE 
Mains Fuse 
F501 
Walter 
TSD 
T1.6AL   250V 
 
IEC 60127 
 
 
Mains plug 
I-Sheng 
SP-21A 
2.5A   250V 
CEE 7 
 
Mains cord 
I-Sheng 
H03VVH2-F 
2 x 0.75mm² 
IEC 60227 
 
Mains switch 
SW501 
Rong Feng 
RF-1003 
10(4)A  250V 
8/80A 
Class II 
IEC 61058 
IEC60065 Annex G.1.1
 
 
X2-capacitors 
across L-N 
(EMI filter) 
Europtronic MPX  0.1µF 
and 
0.22µF 275V 
IEC 60384-14 
2
nd
 edition 
 
 
Mains fuse 
holder 
Shin Chin 
R3-45 
94V-0 
Complies with 
IEC60707:1981 
FH3-40mm/min 
Fuse board 
Hsiang Kuo 
Industrial Co. 
Ltd. 
07V0 94V-0 
Complies 
with 
IEC 60707:1981
 
FV 1 
 
PCB 
(for EMI filter) 
 
 
 
 
 
Insulation Tube 
(for EMI filter) 
Dongguan 
Quantai 
Electronics 
Co. Ltd. 
T-2 VW-1 
Complies 
with 
IEC 60707:1981
  
FH 3-40 mm/min 
 
 
page 24 of 28 
Ref.No.: 410586 
IEC 60065 
Cl. 
Requirement - Test 
Result - Remark 
Verdict 
 
 
TRF No.: I60065__C 
 
 
 GROUP DIFFERENCES (COMMON MODIFICATIONS) TO IEC 60065   
 
 
CONTENTS 
Add the following annexes: 
Annex ZB (normative) Special national conditions 
Annex ZC (informative) A-deviations 
 Noted 
1.1.1 
Replace the text of note 1 by: 
NOTE 1  This standard can be used as a guide for 
the testing of battery operated apparatus. 
 Noted 
3.1 Delete 
the 
note. 
Add the following indent: 
Exposure to excessive sound pressures from 
headphones or earphones  
NOTE  A new method is under consideration by 
CENELEC/TC 206 
 Noted 
15.1.1 
Delete notes 1 and 2. 
Add to note 4: 
Attention is drawn to the fact that a standard is 
under preparation (presently prEN 50074) for 
socket-outlets which allow connection of Class II 
appliances only. 
 Noted 
15.2 
Delete note 2. 
 
Noted 
16.1 
Delete note 1. 
 
Noted 
16.2 Delete 
the 
note. 
 
Noted 
20 
Delete note 2. 
 
Noted 
Annex B 
Delete note 2. 
 
Noted 
B.5.4.1e) 
Delete notes 1 and 2. 
 
Noted 
B.8.1 
Delete notes 1, 2 and 3. 
 
Noted 
B.8.2 Delete 
the 
note. 
 
Noted 
B.14.12 
Delete notes 1 and 2. 
 
Noted 
Annex G 
Delete the note. 
 
Noted 
 
Page of 44