page 17 of 28 
Ref.No.: 410586 
IEC 60065 
Cl. 
Requirement - Test 
Result - Remark 
Verdict 
 
 
TRF No.: I60065__C 
 
17.8 
Fixing devices for detachable legs or stands 
provided 
 N 
17.9 
 P 
 
18 
MECHANICAL STRENGTH OF PICTURE TUBES AND PROTECTION AGAINST 
THE EFFECTS OF IMPLOSION 
 
18.1 
Picture tube separately approved  ......................... :  
 
Picture tubes > 16 cm intrinsically protected 
 
 
Non-intrinsically protected tubes > 16 cm used 
with protective screen 
 N 
18.2 
Intrinsically protected tubes: tests on 12 samples 
 
18.2.1 
Samples subject to ageing: 6 
 
18.2.2 
Samples subject to implosion test: 6 
 
18.2.3 
Samples subject to mechanical strength test (steel 
ball): 6 
 N 
18.3 
Non-intrinsically protected tubes tested to 18.3 
 
 
19 
STABILITY AND MECHANICAL HAZARDS 
 
 
Mass of the equipment exceeding 18 kg  .............. : No 
19.1 
Test on a plane, inclined at 10º to the horizontal 
 
19.2 
100 N applied vertically downwards 
 
19.3 
Smooth edges and corners 
 
19.4 
Glass surfaces with an area exceeding 0.1 m
2
 or 
maximum dimension > 450 mm, pass the test of 
19.4.1 
 N 
 
20 
RESISTANCE TO FIRE                                            (See list of critical components.)   
 
Electrical components and mechanical parts 
 
a) Exemption for components contained in an 
enclosure of material FV 0 to IEC 60707 with 
openings not exceeding 1 mm in width 
 N 
 
b) Exemption for small components as defined in 
20.1 
 P 
20.1.1 
Electrical components meet the requirements of 
14.2.5, 14.4, 14.5.3, 14.6.6 or 20.1.4 
 P 
20.1.2 
Insulation of internal wiring working at voltages 
> 4 kV or leaving an internal fire enclosure, not 
contributing to the spread of fire 
 N 
 
 
page 18 of 28 
Ref.No.: 410586 
IEC 60065 
Cl. 
Requirement - Test 
Result - Remark 
Verdict 
 
 
TRF No.: I60065__C 
 
20.1.3 
Material of printed circuit boards on which the 
available power exceeds 15 W at a voltage 
between 50 V and 400 V (peak) a.c. or d.c. meets 
FV 1 or better to IEC 60707, unless used in a fire 
enclosure 
 P 
 
Material of printed circuit boards on which the 
available power exceeds 15 W at a voltage 400 V 
(peak) a.c. or d.c. meets FV 0 to IEC 60707 
 N 
20.1.4 
Components and parts not covered by 20.1.1, 
20.1.2 and 20.1.3 (other than fire enclosures) 
mounted nearer to a potential ignition source than 
the distances in Table 13 comply with the relevant 
flammability category in Table 13 
 (see critical components) 
 
Components and parts as above but shielded from 
a potential ignition source, with the barrier area in 
accordance with Table 13 and fig. 13 
 N 
20.2 
Fire enclosure 
20.2.1 
Potential ignition sources with open circuit voltage 
> 4 kV (peak) a.c. or d.c. contained in a fire 
enclosure to FV 1 
 N 
20.2.2 
 N 
20.2.3 
Requirements of 20.2.1 and 20.2.2 met by an 
internal fire enclosure 
 N 
 
APPENDIX A, ADDITIONAL REQUIREMENTS FOR APPARATUS WITH 
PROTECTION AGAINST SPLASHING WATER 
 
A.5.1 
j) Marked with IPX4 (IEC 60529), 5.4.1 a) does not 
apply 
 N 
A.10.2.1 
Enclosure provides protection against splashing 
water 
 N 
A.10.2.2 
Humidity treatment carried out for 7 days 
 
 
 
 
page 19 of 28 
Ref.No.: 410586 
IEC 60065 
Cl. 
Requirement - Test 
Result - Remark 
Verdict 
 
 
TRF No.: I60065__C 
 
APPENDIX B, APPARATUS TO BE CONNECTED TO THE 
TELECOMMUNICATION NETWORKS 
 
B.5.4.1 
e) Where the separation of TNV circuits from other 
circuits relies on protective earthing the 
instructions make it clear that protective earthing is 
essential 
 N 
B.8.1 
TNV circuits separated from the mains circuit and from hazardous live parts by 
either: 
 
 
a) double or reinforced insulation 
 
 
b) basic insulation with earthed protective 
screening 
 N 
B.8.2 
TNV circuits separated from circuits other than 
those in B.8.1 and from accessible conductive 
parts by basic insulation meeting the requirements 
for clearances and creepage distances for the 
voltages concerned 
 N 
B.9.1.1 
TNV circuit terminals contacts which cannot be 
touched by probe B.1, exempt from the 
requirements inaccessible terminal contacts in 
9.1.1 
 N 
B.10.1 
Insulation between TNV terminals and antenna 
terminals (including interconnection terminals 
which may be connected to equipment with 
antenna terminals) withstands the 50 discharges of 
10.1 
 N 
B.14.12 
Surge suppressors between TNV circuits and 
other parts of the equipment have breakdown 
voltage at least 1.8 times the mains voltage 
 N 
 
 
 
page 20 of 28 
Ref.No.: 410586 
IEC 60065 
Cl. 
Requirement - Test 
Result - Remark 
Verdict 
 
 
TRF No.: I60065__C 
 
7.1 
TABLE: temperature rise measurements 
 
 
Power consumption in the OFF/Stand-by 
Position of the functional switch (W)  ..................... :
 
0 W 
 
Operating conditions 
1/8 of max. non-clipping output power (pink noise)  
Un (V) 
In (A) 
Pn (W) 
Pout (W) 
254.4 0.2  30  18.8 
 
Loudspeaker impedance (
Ω) ................................ : 4Ω 
 
 Several 
loudspeaker 
systems 
 
Marking of loudspeaker terminals 
 
monitored point: 
dT (K) 
Permitted dT (K) 
Toroid transformer outside. 
17 
— 
Supply wiring insulation (Not under mechanical stress.) 
<20 
60 
PCB/heat sink 
20 
85 
Buttons (plastic) 
<10 
50 
Enclosure (wood) 
<10 
60 
Enclosure (metal) 
12 
40 