Page 6 of 58 
Report No.: 1009950 
IEC 60065 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
 
TRF No. IEC60065J 
3 General 
requirements 
 
 
Safety class of the 
apparatus …………………………: 
Class II 
 
General test conditions 
 
4.1.4 
Ventilation instructions require the use of the test box  No 
N/A 
 
Marking and instructions 
 
 
Comprehensible and easily discernible 
 
 
Permanent durability against water and petroleum 
spirit  
 P 
5.1 a) 
Identification, maker ........................................... : 
,  
 
b) Model number or type reference…………………: 
ES150P/230 and ES150PW/230
 
c) Class II symbol if applicable…………………….. : 
 
 d) 
Nature 
of supply .................................................. : 
 
 
e) Rated supply voltage........................................... : Subwoofer: AC 220-230V~ 
Transmitter: 18V
 
 
f) Mains frequency if safety dependant ................... : 
50/60Hz P 
g) Rated current or power consumption for 
apparatus supplied by supply apparatus for general 
use ........................................................................... : 
 N/A 
Measured current or power consumption  .............. : 
 
N/A 
 
Deviation %  (max 10%)  ......................................... : 
 
N/A 
 
h) Power consumption marking for apparatus other 
than single phase ……………………………………: 
 N/A 
i) Rated current or power consumption for apparatus 
intended for connection to an a.c. mains supply ….: 
Subwoofer ES150P/230: 1A 
Subwoofer ES150PW/230: 200W 
Transmitter: 0.4A 
Measured current or power consumption………….: 
0.43A 
 
Deviation %  (max 10%)……………………………..: 
-57% 
5.2 
Earth terminal  
 
N/A 
 
Hazardous live terminals  
 
N/A 
 
Supply output terminals (other than mains)  
 
N/A 
5.3 
Use of triangle with exclamation mark  
In circuit diagram 
5.4 
Instructions for use  
 
5.4.1 
 
a) Mains powered equipment not exposed to 
dripping or splashing. Warning concerning objects 
filled with liquid, etc.  
 P 
 
Page 7 of 58 
Report No.: 1009950 
IEC 60065 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
 
TRF No. IEC60065J 
 
b) Hazardous live terminals, instructions for wiring   
 
N/A 
 
c) Instructions for replacing lithium battery  
 
N/A 
 
d) Class I earth connection warning  
 
N/A 
 
e) Instructions for multimedia system connection  
 
N/A 
 
f) Special stability warning for attachment of the 
apparatus to the floor/wall  
 N/A 
 
g) Warning: battery exposure to heat  
 
N/A 
 
h) Warning: protective film on CRT face  
 
N/A 
5.4.2 
a-b) Disconnect device: plug/coupler or all-pole 
mains switch location, accessibility and markings  
Mains plug, text in instruction 
manual provided. 
 
c) Instructions for permanently connected equipment   
N/A 
 
Marking, signal lamps or similar for completely 
disconnection from the mains  
ON=green LED, Standby=red LED
All-pole mains switch marked  
I and O 
 
6 Hazardous 
radiation 
 
6.1 
Ionizing radiation < 36 pA/kg (0,5 mR/h)  
 
N/A 
 
Ionizing radiation under fault condition  
 
N/A 
6.2 
Laser radiation, emission limits to IEC 60825-1 …….:  
N/A 
 
Emission limits under fault 
conditions ………………..: 
 N/A 
 
Heating under normal operating conditions 
 
7.1 
Temperature rises not exceeding specified values; 
fuse links and other protective devices defeated  
(see appended table) 
7.1.1 
Temperature rise of accessible parts  
(see appended table) 
7.1.2 
Temperature rise of parts providing electrical 
insulation  
(see appended table) 
7.1.3 
Temperature rise of parts acting as a support or as a 
mechanical barrier  
(see appended table) 
7.1.4 
Temperature rise of windings  
(see appended table) 
7.1.5 
Parts not subject to a limit under 7.1.1 to 7.1.4 
(see appended table) 
7.2 
Softening temperature of insulating material 
supporting parts conductively connected to the 
mains carrying a current > 0,2 A at least 150
 o
C  
Maisn fuse holder 
(see appended table) 
 
 
Page 8 of 58 
Report No.: 1009950 
IEC 60065 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
 
TRF No. IEC60065J 
Constructional requirements with regard to the protection against electric shock
 
8.1 
Conductive parts covered by lacquer, paper, 
untreated textile oxide films and beads etc. 
considered to be bare  
PCB P 
8.2 
No shock hazard when changing voltage setting 
device, fuse-links or handling drawers etc.  
Tools are required 
N/A 
8.3 
Insulation of hazardous live parts not provided by 
hygroscopic material  
 P 
8.4 
No risk of electric shock from accessible parts or 
from parts rendered accessible following the removal 
of a cover which can be removed by hand  
 P 
8.5 
Class I equipment  
 
N/A 
 
Basic insulation between hazardous live parts and 
earthed accessible parts  
 N/A 
 
Resistors bridging basic insulation complying with 
14.1 a)  
 N/A 
 
Capacitors bridging basic insulation complying with 
14.2.1 a)  
 N/A 
 
Protective earthing terminal  
 
N/A 
8.6 
Class II equipment and Class II constructions within 
Class I equipment  
 P 
 
Double or reinforced insulation between hazardous 
live parts and accessible parts  
 P 
 
Components bridging double or reinforced insulation 
complying with 14.1 a) or 14.3  
Main transformer and standby 
transformer TR1 
 
Basic insulation bridged by components complying 
with 14.3.4.3.  
 N/A 
 
Basic and supplementary insulation each being 
bridged by a capacitor complying with 14.2.1 a)  
 N/A 
 
Double or reinforced insulation being bridged with 2 
capacitors in series complying with 14.2.1 a)  
 N/A 
 
Double or reinforced insulation being bridged with a 
single capacitor complying with 14.2.1 b)  
C03 P 
8.7 
This clause is void  
 
 
8.8 
Basic or supplementary insulation > 0,4 mm (mm) ...: Primary wires are double 
insulated. Tubing on standby 
PCB. 
 
Reinforced insulation > 0,4 mm (mm) ……………….:  
N/A 
 
Thin sheet insulation (excluding non-separable thin 
sheet insulation. See 8.22)  
Tape in Main transformer and 
TIW in TR1 
 
Page 9 of 58 
Report No.: 1009950 
IEC 60065 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
 
TRF No. IEC60065J 
 
Basic or supplementary insulation, at least two 
layers, each meeting 10.3  
 N/A 
 
Basic or supplementary insulation, three layers any 
two of which meet 10.3  
 N/A 
 
Reinforced insulation, two layers each of which meet 
10.3  
 N/A 
 
Reinforced insulation, three layers any two which 
meet 10.3  
Thin sheet insulation with a 
thickness of 0.10 mm. in mains 
transformer and TIW in TR1
 
8.9 
Adequate insulation between internal hazardous live 
conductors and accessible parts  
 
 
Adequate insulation between internal hazardous live 
parts and conductors connected to accessible parts  
 P 
Double insulation between conductors connected to 
the mains and accessible parts.  
Primary wires are double  
insulated.  
8.10 
Double insulation between internal  hazardous live 
parts and conductors connected to accessible parts. 
No secondary wires can come 
into contact with primary parts. 
8.11 
Detaching of wires  
 
N/A 
 
No undue reduction of creepages or clearance 
distances if wires become detached  
No risk of any wire becoming 
detached. 
N/A 
 
Vibration test carried out .........................................: 
No need, see above 
N/A 
8.12 
This clause is void  
 
 
8.13 
Adequate fastening of windows, lenses, lamp covers 
etc. (pull test 20 N for 10 s)  
 N/A 
8.14 
Adequate fastening of covers (push/pull test 50 N for 
10 s)  
 P 
8.15 
No risk of damage to the insulation of internal wiring 
due to hot parts or sharp edges  
 P 
8.16 
Only special supply equipment can be used  
 
N/A 
8.17 
Insulated winding wire without additional interleaved 
insulation  
In Standby transformer 
8.18 
Endurance test as required by 8.17  
 
N/A 
8.19 
Disconnection from the mains 
 
8.19.1 
Disconnect device  
Mains Plug/connector 
 
All-pole switch or circuit breaker with >3mm contact 
separation  
 N/A 
8.19.2 
Mains switch ON indication  
 
N/A 
8.20 
Switch not fitted in the mains cord  
 
N/A 
8.21 
Bridging components comply with clause 14  
C15 (over relay contacts) 