Page 22 of 58 
Report No.: 1009950 
IEC 60065 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
 
TRF No. IEC60065J 
Annex A, Additional requirements for apparatus with protection against 
splashing water 
 
A.5 
Marking and instructions 
 
N/A 
A.5.1 
j) Marked with IPX4 (IEC 60529), 5.4.1 a) does not 
apply  
 N/A 
A.10 Insulation 
requirements 
 
N/A 
A.10.2 
Splash and humidity treatment 
 
N/A 
A.10.2.1 
Enclosure provides protection against splashing 
water  
 N/A 
A.10.2.2 
Humidity treatment carried out for 7 days  
 
N/A 
 
Annex B, Apparatus to be connected to the TELECOMMUNICATION NETWORKS 
 
 
Complies with IEC 62151 clause 1  
 
N/A 
 
Complies with IEC 62151 clause 2  
 
N/A 
 
Complies with IEC 62151 clause 3 but with 3.5.4 
modified to 2.4.10 of this standard  
 N/A 
 
Complies with IEC 62151 clause 4 but with 4.1.2, 
4.1.3 and 4.2.1.2 modified in accordance with annex 
B of this standard  
 N/A 
 
Complies with IEC 62151 cause 5 but with 5.3.1 
modified in accordance with annex B of this  
standard  
 N/A 
 
Complies with IEC 62151 clause 6  
 
N/A 
 
Complies with IEC 62151 clause 7  
 
N/A 
 
Complies with IEC 62151 annex A, B and C  
 
N/A 
 
ANNEX L, Additional requirements for electronic flash apparatus for 
photographic purposes 
 
L. 5 
Marking and instructions 
 
N/A 
L. 5.4 
Instructions for battery chargers and Supply 
apparatus indicating type or model number of flash 
apparatus with which it is to be used  
 N/A 
 
Instructions for flash apparatus indicating type or 
model number of battery chargers or Supply 
apparatus with which it is to be used  
 N/A 
L. 7 
Heating under normal operating conditions 
 
N/A 
L7.1.5 & 
L11.2.6 
Lithium batteries meet permissible temp rise in Table 
 3 , unless comply with 6.2.2.1.or 6.2.2.2 of  
IEC 60086-4  
 N/A 
 
Page 23 of 58 
Report No.: 1009950 
IEC 60065 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
 
TRF No. IEC60065J 
L. 9 
Electric shock hazard under normal operating 
conditions 
 N/A 
L. 9.1.1 
Terminals to connection to synchroniser not 
HAZARDOUS LIVE  
 N/A 
L.10 Insulation 
requirements 
 
N/A 
L. 10.3.2 
High frequency puls ignition  
 
N/A 
L. 12 
Mechanical strength 
 
N/A 
L. 12.1.3 
Windows for flash tubes are excluded from steel ball 
impact test  
 N/A 
L. 14 
Components 
 
N/A 
L14.6.6 
Mains switch characteristics appropriate to its 
function under normal conditions  
 N/A 
L. 20 
Resistance to fire 
 
N/A 
L. 20.1 c) 
Trigger coil for discharge purpose is not considered 
to be a POTENTIAL IGNITION SOURCE  
 N/A 
 
 
Page 24 of 58 
Report No.: 1009950 
IEC 60065 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
 
TRF No. IEC60065J 
7.1 
TABLE: temperature rise measurements 
 
Power consumption in the OFF/Stand-by position of 
the functional switch (W)……………………… ……..: 
0W/0.2W 
— 
 
Cond. 
Un (V) 
Hz 
In (mA) 
Pn (W) 
V out 
Pout (W) 
Operating Condition 
1 253 50 386  55  11.5  37 
2 198 50 342  45  9.8  27 
1/8 of max non-clipping output 
power (pink noise) 
Transformer model TT0900901830-E 
 
Loudspeaker impedance (Ω) ..................................: 
Measured DC resistance: 3.54Ω 
— 
 
Several loudspeaker systems 
— 
 
Marking of loudspeaker terminals 
— 
— 
 
Temperature Rise dT of Part 
dT (K) 
Limit max dT (K) 
Test Condition No. 
No 1 
No ___ 
No ___ 
 
Primary wiring insulation 
24 
60 (50) 
Transformer steel washer                               
35 
PCB 37 
85 
(75) 
Heat sink (supported by PCB) 
37 
85 (75) 
33 
60 (50) 
Rear panel, metal (likely to be touched) 
outside of heat sink 
26 -  - 
40 
(30) 
Knobs (non metallic) 
13 
50 (40) 
Top enclosure, wood 
60 (50) 
TR1 windings (measured with thermocouple) 
24 
75 (65) 
PCB (Standby SMPS)) 
22 
85 (75) 
Winding temperature rise measurements 
Ambient temperature t1 (
o
C) ..............................
Ambient temperature t2 (
o
C) ..............................
23 
26 
— —  — 
— 
Temperature rise dT of winding: 
dT = (R
– R
1
) x (234.5 + t1) – (t2 – t1) 
             R
1
 
R
1
 (Ω) 
R
2
 (Ω) 
dT (K) 
Limit 
maxK) 
Insulation class 
Transformer model TT0900901830-E 
Primary winding 
5.279 
6.057 
35 
85 (75) 
Secondary winding (red-red) 
0.5564 
0.6332 
33 
85 (75) 
Secondary winding (blue-blue) 
1.4914 
1.7005 
33 
85 (75) 
The limit values in parenthesis are the limit values for tropical climate. 
 
Page 25 of 58 
Report No.: 1009950 
IEC 60065 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
 
TRF No. IEC60065J 
7.1 
TABLE: temperature rise measurements 
 
Power consumption in the OFF/Stand-by position of 
the functional switch (W)……………………… ……..: 
0W/0.2W 
— 
 
Cond. 
Un (V) 
Hz 
In (mA) 
Pn (W) 
V out 
Pout (W) 
Operating Condition 
1 253 50 340  51  11.5  37 
2 198 50 330  40  9.8  27 
1/8 of max non-clipping output 
power (pink noise) 
Transformer model
 TD-230-0300A+C 
 
Loudspeaker impedance (Ω) ..................................: 
Measured DC resistance: 3.54Ω 
— 
 
Several loudspeaker systems 
— 
 
Marking of loudspeaker terminals 
— 
— 
 
Temperature Rise dT of Part 
dT (K) 
Limit max dT (K) 
Test Condition No. 
No 1 
No ___ 
No ___ 
 
Primary wiring insulation 
24 
60 (50) 
Transformer steel washer                               
26 
PCB 35 
85 
(75) 
Heat sink (supported by PCB) 
35 
85 (75) 
31 
60 (50) 
Rear panel, metal (likely to be touched) 
outside of heat sink 
24 -  - 
40 
(30) 
Knobs (non metallic) 
11 
50 (40) 
Top enclosure, wood 
60 (50) 
TR1 windings (measured with thermocouple) 
24 
75 (65) 
PCB (Standby SMPS) 
22 
85 (75) 
Winding temperature rise measurements 
Ambient temperature t1 (
o
C) ..............................
Ambient temperature t2 (
o
C) ..............................
21 
24 
— —  — 
— 
Temperature rise dT of winding: 
dT = (R
– R
1
) x (234.5 + t1) – (t2 – t1) 
             R
1
 
R
1
 (Ω) 
R
2
 (Ω) 
dT (K) 
Limit 
maxK) 
Insulation class 
Transformer model
 TD-230-0300A+C
 
Primary winding 
5.324 
5.994 
29 
85 (75) 
Secondary winding (red-red) 
0.4488 
0.5022 
27 
85 (75) 
Secondary winding (blue-blue) 
1.2013 
1.3435 
27 
85 (75) 
The limit values in parenthesis are the limit values for tropical climate. 