Report No.:
EM201200813-7
Application No.:
ZJ00024740
Page 29 of 47
5.3 ELECTROSTATIC DISCHARGE (ESD)
5.3.1 TEST SPECIFICATION
Basic Standard
EN 61000-4-2:
2009
Discharge Impedance
330 ohm / 150 pF
Discharge Voltage
Air Discharge : 8 kV;
Contact Discharge: 4 kV
Polarity
Positive & Negative
Number of Discharge
Minimum 10 times at each test point
Discharge Mode
Single Discharge
1 second minimum
5.3.2 TEST PROCEDURE
a) The EUT was located 0.1 m minimum from all side of the HCP (dimensions 1.6m * 0.8m).
b) The support units were located another table 30 cm away from the EUT, but direct support unit
was/were located at same location as EUT on the HCP and keep at a distance of 10 cm with EUT.
c) The time interval between two successive single discharges was at least 1 second.
d) Contact discharges were applied to the non-insulating coating, with the pointed tip of the generator
penetrating the coating and contacting the conducting substrate.
e) Air discharges were applied with the round discharge tip of the discharge electrode approaching the
EUT as fast as possible (without causing mechanical damage) to touch the EUT. After each
discharge, the ESD generator was removed from the EUT and re-triggered for a new single
discharge. The test was repeated until all discharges were complete.
f) At least ten single discharges (in the most sensitive polarity) were applied at the front edge of each
HCP opposite the center point of each unit of the EUT and 0.1 meters from the front of the
EUT. The long axis of the discharge electrode was in the plane of the HCP and perpendicular to its
front edge during the discharge.
Report No.:
EM201200813-7
Application No.:
ZJ00024740
Page 30 of 47
g) At least ten single discharges (in the most sensitive polarity) were applied to the center of one
vertical edge of the Vertical Coupling Plane (VCP) in sufficiently different positions that the four
faces of the EUT were completely illuminated. The VCP (dimensions 0.5m * 0.5m) was placed
vertically to and 0.1 meters from the EUT.
5.3.3 TEST SETUP
Report No.:
EM201200813-7
Application No.:
ZJ00024740
Page 31 of 47
5.3.4 TEST RESULTS
EUT
Wireless high-power speaker for lighting connector
Mode Number
JBL ONBEAT RUMBLE
Test date
2013-01-04
Voltage Supply
AC 230V/50Hz
Test Engineer
Liang
environment
Tem:25 Hum:50 %100kPa
Test mode:
1. Test the EUT in Audio in, Audio in (Loading), Audio in (Headset),
Audio in (Headset and Loading), iPhone5, iPhone5 (Loading),
iPhone5 (Headset), iPhone5 (Headset and Loading)
iPhone5 (Headset), iPhone5 (Headset and Loading)
2. Test the EUT in idle mode.
Discharge point
Discharge
voltage
C-Conduct
A-Air
Required
Passing
Performance
Actual
performance
Result
Nonmetallic
exposed surface &
button
±8 kV
A
Criterion B
Criterion A*
PASS
Vertical coupling
plane
±4 kV
C
Criterion B
Criterion A*
PASS
Horizontal coupling
plane
±4 kV
C
Criterion B
Criterion A*
PASS
A*: There was no change compared with the initial operation during the test..
Report No.:
EM201200813-7
Application No.:
ZJ00024740
Page 32 of 47
5.4 IMMUNITY TO RF VOLTAGE OF MAINS, LOUDSPEAKER, HEADPHONE
AND AUDIO CONNECTERS (S2A)
5.4.1 TEST REQUIREMENT
Test Requirement:
EN 55020
Test Method:
EN 55020
Criterion Required:
A
Wanted Signal:
60dBuV 1KHz FM with 40KHz deviation at 98MHz for FM mode.
1KHz Test DVD/CD/Tape/sine wave for AUX mode.
Unwanted Signal:
1KHz AM 80% AM at the frequency listed below.
Examption frequencies:
Unwanted signal and immunity limit for Mains, Loudspeaker and Headphone terminals.
Unwanted signal and immunity limit for audio input / output terminals.