DOWNLOAD JBL SCS 146 Sub (serv.man2) Service Manual ↓ Size: 6.3 MB | Pages: 16 in PDF or view online for FREE

Model
SCS 146 Sub (serv.man2)
Pages
16
Size
6.3 MB
Type
PDF
Document
EMC - CB Certificate
Brand
Device
Audio
File
scs-146-sub-sm2.pdf
Date

JBL SCS 146 Sub (serv.man2) EMC - CB Certificate ▷ View online

 
 
page 5 of 9 
Ref.No.:407363  
IEC 60065 
Clause 
Requirement - Test 
Result - Remark 
Verdict 
 
 
TRF No.: I60065__C 
 
11.2.5 
Temperature rise of windings 
 
11.2.6 
Temperature rise of other parts not subject to the 
limits of 11.2.1 to 11.2.5 
 P 
 
7.1 
TABLE: temperature rise measurements 
 
Power consumption in the OFF/Stand-by 
 
 
 
Position of the functional switch (W)  ..................... : - 
 
Operating conditions 
1/8 of the max. non-clipping output power using the pink noise signal acc. to 4.1.6 .  
 
Un (V) 
In (A) 
Pn (W) 
Pout (W) 
                254.4 
0.40 
72 
31 
 
Loudspeaker impedance (
Ω) ................................ : 3.4Ω (measured) 
 
 
Several loudspeaker systems 
 
 
Marking of loudspeaker terminals 
(High Level  out/in) 
 
monitored point: 
dT (K) 
Permitted dT (K)  
 * indicates for 
tropical climates. 
Iron core of mains transformer  
43 
— 
Supply cords (Not under mechanical stress) 
20 
60/50* 
PCB  
26 
85/75* 
Inside top of internal plastic cover  
17 
— 
Heat sink, on rear panel 
24 
40/30* 
Rear panel, above heat sink 
25 
40/30* 
Volume control (plastic) 
19 
50/40* 
Top of cabinet 
60/50* 
 
Winding temperature rise measurements 
 
 
Ambient temperature t1 (ºC)  ................................. : 20 
 
 
Ambient temperature t2 (
°C) ................................. : 21 
 
temperature rise dT of winding: 
R
1
 (
Ω) 
R
2
 (
Ω) 
dT (K) 
permitted 
dT (K) 
insulation 
class 
Transformer Primary vinding 
8.885 
10.565 
47 
85/75* 
Transformer Secondary winding (Yellow) 
0.5635 
0.6646 
45 
85/75* 
Transformer Secondary winding (Red) 
1.0953 
1.2960 
46 
85/75* 
 
 
page 6 of 9 
Ref.No.:407363  
IEC 60065 
Clause 
Requirement - Test 
Result - Remark 
Verdict 
 
 
TRF No.: I60065__C 
 
10 INSULATION 
REQUIREMENTS 
 
 
 
(See appended table) 
 
10.1 
Insulation resistance (M
Ω) at least 2 MΩ min. after 
surge test for basic and 4 M
Ω min. for reinforced 
insulation 
>100M
Ω 
10.2 
Humidity treatment 48 h or 120 h 
48 h (see also page 8) 
10.3 
Insulation resistance and dielectric strength 
 
 
 
 
10.3 
TABLE: insulation resistance measurements 
insulation resistance R between: 
R (M
Ω) 
required R (M
Ω) 
Between the poles of the circuit directly connected to the 
supply mains. 
>10 min.2 
Reinforced insulation. 
>10 
min.4 
 
 
10.3 TABLE: 
electric 
strength 
measurements 
test voltage applied between: 
test voltage (V) 
Breakdown 
Between the poles of the circuit directly connected to the 
supply mains. 
2120V peak 
No 
Reinforced insulation. 
4240V peak 
No 
 
 
 
 
page 7 of 9 
Ref.No.:407363  
IEC 60065 
Clause 
Requirement - Test 
Result - Remark 
Verdict 
 
 
TRF No.: I60065__C 
11.2 
TABLE: summary of fault condition tests 
 
Voltage (V) 0.9 or 1.06 times rated voltage  .......... : 220-240 
 
 
Ambient temperature (
°C) ..................................... : 21 
 
 
Winding temperature rise measurements 
 
 
Ambient temperature t1 (ºC)  ................................. : 20 
 
 
Ambient temperature t2 (ºC)  ................................. : 21 
 
No
Component 
No. 
Fault  Test voltage
 (V) 
Test  
time 
Fuse No.
Fuse  
current 
(A) 
Result 
1 Max. 
non-
clipping 
output 
power  
(Pink noise) 
— 254.4  4h Mains 
fuse 
0.6 
Pn = 110W. Uout=15.5V (limited 
by the amplifier) 
Measured temp.rises:  
Mains transformer: 
Prim. winding  = 56K 
Sec. windings = 56K 
PCB = 26K 
Rear panel (metal) = 26K 
Heat sink (on rear side) = 24K
 
No remarks. 
 
 
page 8 of 9 
Ref.No.:407363  
IEC 60065 
Clause 
Requirement - Test 
Result - Remark 
Verdict 
 
 
TRF No.: I60065__C 
 
 
 
 
 
 
 
 
    
National differences for Singapore                                                                            
(These differences are taken from IEC 60065:1993 and adopted to IEC 60065:1998)
 
 
 
IEC 60065: 1998 
Clauses:  4, 7, 9, 10 and 16.                                                                                                              
 
 
 
Throughout the standard, whenever the words "white pine board" appear, insert  
the words "or plywood board" to it. 
Noted 
 
SS143 Amendment No. 1 and No. 2 
 
4.1.3 
(4.1.3)* 
Delete "45 % to 75 %" and insert 65 ± 5 %. 
75% maximum in IEC 60065: 
1998 
7.1 
(7.1) 
Resistance to heat without external forces. 
Adopt the temperature specified for the tropical 
conditions. 
 P 
8.6 
(9.3.4) 
Delete the note " A Quality Assessment System 
for capacitors complying with Subclause 14.2 is 
under consideration in the IEC". 
This is not in IEC 60065:1998. 
Noted 
10.2 
(10.2) 
Humidity treatment 
Adopt the testing conditions designed for tropical 
conditions. 
120h at 93% relative humidity 
16 
(16) 
External flexible cords 
Delete "IEC Publication 60227: Polyvinyl Chloride 
Insulated Cables of Rated Voltages up to and 
Including 450/750 V and IEC publication 60245: 
Rubber insulated Cables of rated up to and 
including 450/750 V " and insert "Singapore 
Standard 236: Flexible Cords", whenever they 
appear in this clause. 
Delete "CEE Publication 13, CEE Publication 2 
and IEC Publication 60173: Colours of the Cores 
of Flexible Cables and Cords" whenever they 
appear in this clause. 
 Noted 
16.2 
(16.2) 
Delete the notes in small print and insert  "A 
nominal cross-sectional area of  0.75 mm² will 
satisfy this requirement". 
This is not in IEC 60065:1998. 
 
* in parenthesis: clauses acc. to IEC 60065:1993 
 
 
Page of 16
Display

Click on the first or last page to see other SCS 146 Sub (serv.man2) service manuals if exist.