page 1 of 9 
Ref.No.:407363  
 
TRF No.: I60065__C 
TEST REPORT 
IEC 60065 
Audio, video and similar apparatus 
Safety requirements 
Report 
Reference No. ................................... :  407363 
Tested by (+ signature) ..................... :  Josef Ismail 
.......................................................
 
Approved by (+ signature)................. : 
 
Kjell Fredriksson 
 
.......................................................
Date of issue ..................................... :  21 September 2004 
Contents............................................ :  See below.   
Testing laboratory 
Name................................................. :  Intertek Semko AB 
Address ............................................. :  P.O. Box 1103, SE-164 22, Kista, SWEDEN 
Testing location ................................. :  Torshamnsgatan 43, Kista, SWEDEN 
Client 
Name................................................. :  HARMAN CONSUMER GROUP 
Address ............................................. : 250 Crossways Park Drive, Woodbury, New York,NY 11797-2015 
USA 
Test specification 
Standard............................................ :  IEC 60065:1998  Group differences and national differences for the 
CENELEC countries.(EN 60065) 
Test procedure  ................................. :  CB-scheme 
Procedure deviation .......................... :  N.A. 
Non-standard test method ................ :  N.A. 
Test Report Form/blank test report 
Test Report Form No. ....................... : 60065__C/99-02 
Master TRF ....................................... :  Reference No. 60065, dated 98-12 
First Modification to Test Report No.:   308860                                                                                             
Modification of appliance……………:   Addition of the Singapore differences and changing of the heat sink.  
Clause concerned……………………:  7, 10, 11 and the national differences for Singapore. 
 
Page 1-7: 
 Relevant parts of IEC 60065 Test Report  
Page 7-9: 
National differences for Singapore 
 
 
page 2 of 9 
Ref.No.:407363  
 
TRF No.: I60065__C 
Test item 
Description ........................................ : Powered subwoofer 
Trademark......................................... : 
 (See also page 3)   
 
Model and/or type reference ............. :  SUB200/230 (See also page 3) 
Manufacturer ..................................... :  Harman Consumer Group 
Rating(s)............................................ :  AC 220-240V , 50Hz-60Hz, 220W, Class 
ΙΙ 
Test case verdicts 
Test case does not apply to the test object..................: N (Not Applicable) 
Test item does meet the requirement ..........................: P (Pass) 
Test item does not meet the requirement ....................: F (Fail) 
Testing 
Date of receipt of test item  ..........................................: 13 September 2004 
Date(s) of performance of test .....................................: 18-21 September 2004 
General remarks 
 
“This report is not valid as a CB Test Report unless appended to a CB Test Certificate issued by a NCB, in 
accordance with IECEE 02”. 
 
This test report shall not be reproduced except in full without the written approval of the testing laboratory. 
 
The test results presented in this report relate only to the item tested. 
 
“(see remark #)” refers to a remark appended to the report. 
 
“(see appended table)” refers to a table appended to the report. 
 
Throughout this report a point is used as the decimal separator. 
 
 
 
 
 
 
 
 
page 3 of 9 
Ref.No.:407363  
 
TRF No.: I60065__C 
 
Copy of marking plates 
 
 
 
 
 
 
 
 
Note: This test report is also valid for the following models: SUB140/230, SUB146/230, Control Movie 
Subwoofer/230, all with brand name 
 and TSS-450 Subwoofer/230, with brand name
. The 
difference between the models is the model name and for the Infinity model also that the green/red LED is 
located at the front of the cabinet instead of at the back panel. 
 
 
 
 
page 4 of 9 
Ref.No.:407363  
IEC 60065 
Clause 
Requirement - Test 
Result - Remark 
Verdict 
 
 
TRF No.: I60065__C 
 
HEATING UNDER NORMAL OPERATING CONDITIONS (See appended table) 
 
7.1 
Temperature rises not exceeding specified values, 
no operation of fuse links 
 P 
7.1.1 
Temperature rise of accessible parts 
 
7.1.2 
Temperature rise of parts providing electrical 
insulation 
 P 
7.1.3 
Temperature rise of parts acting as a support or as 
a mechanical barrier 
 P 
7.1.4 
Temperature rise of windings 
 
7.1.5 
Parts not subject to a limit under 7.1.1 to 7.1.4 
 
7.2 
Softening temperature of insulating material 
supporting parts conductively connected to the 
mains carrying a current > 0.2 A at least 150 ºC 
Mains fuse holder 
 
 
11 FAULT 
CONDITIONS 
 
    (See 
appended 
table) 
 
11.1 
No shock hazard under fault conditions 
 
11.2 
Heating under fault condition 
 
 
No hazard from softening solder 
 
11.2.1 
Measurement of temperature rises 
 
11.2.2 
Temperature rise of accessible parts 
 
11.2.3 
Temperature rise of parts, other than windings, 
providing electrical insulation 
 P 
 
Temperature rise of printed circuit boards (PCB) 
exceeding the limits of Table 2 by max. 100 K for 
max. 5 min 
 N 
 
a) Temperature rise of printed circuit boards (PCB) 
to 20.1.3, exceeding the limits of Table 2 by not 
more than 100 K for an area not greater than 
2 cm
2
 
 N 
 
b) Temperature rise of printed circuit boards (PCB) 
to 20.1.3 up to 300 K for an area not greater than 
2 cm
2
 for a maximum of 5 min 
 N 
 
Meets all the special conditions if conductors on 
printed circuit boards are interrupted 
At Uin=198V, voltage across 
interruption <50Vp 
At Uin=254.4V, no interruption, 
mains fuse broke 
(see table 11)
 
11.2.4 
Temperature rise of parts acting as a support or 
mechanical barrier 
 P 