JBL SCS 146 Sub (serv.man2) EMC - CB Certificate ▷ View online
page 1 of 9
Ref.No.:407363
TRF No.: I60065__C
TEST REPORT
IEC 60065
Audio, video and similar apparatus
Safety requirements
Report
Reference No. ................................... : 407363
Tested by (+ signature) ..................... : Josef Ismail
.......................................................
Approved by (+ signature)................. :
Kjell Fredriksson
.......................................................
Date of issue ..................................... : 21 September 2004
Contents............................................ : See below.
Testing laboratory
Name................................................. : Intertek Semko AB
Address ............................................. : P.O. Box 1103, SE-164 22, Kista, SWEDEN
Testing location ................................. : Torshamnsgatan 43, Kista, SWEDEN
Client
Name................................................. : HARMAN CONSUMER GROUP
Address ............................................. : 250 Crossways Park Drive, Woodbury, New York,NY 11797-2015
USA
Test specification
Standard............................................ : IEC 60065:1998 Group differences and national differences for the
CENELEC countries.(EN 60065)
Test procedure ................................. : CB-scheme
Procedure deviation .......................... : N.A.
Non-standard test method ................ : N.A.
Test Report Form/blank test report
Test Report Form No. ....................... : 60065__C/99-02
Master TRF ....................................... : Reference No. 60065, dated 98-12
First Modification to Test Report No.: 308860
Modification of appliance……………: Addition of the Singapore differences and changing of the heat sink.
Modification of appliance……………: Addition of the Singapore differences and changing of the heat sink.
Clause concerned……………………: 7, 10, 11 and the national differences for Singapore.
Page 1-7:
Relevant parts of IEC 60065 Test Report
Page 7-9:
National differences for Singapore
page 2 of 9
Ref.No.:407363
TRF No.: I60065__C
Test item
Description ........................................ : Powered subwoofer
Trademark......................................... :
(See also page 3)
Model and/or type reference ............. : SUB200/230 (See also page 3)
Manufacturer ..................................... : Harman Consumer Group
Rating(s)............................................ : AC 220-240V , 50Hz-60Hz, 220W, Class
ΙΙ
Test case verdicts
Test case does not apply to the test object..................: N (Not Applicable)
Test item does meet the requirement ..........................: P (Pass)
Test item does not meet the requirement ....................: F (Fail)
Testing
Date of receipt of test item ..........................................: 13 September 2004
Date(s) of performance of test .....................................: 18-21 September 2004
General remarks
“This report is not valid as a CB Test Report unless appended to a CB Test Certificate issued by a NCB, in
accordance with IECEE 02”.
accordance with IECEE 02”.
This test report shall not be reproduced except in full without the written approval of the testing laboratory.
The test results presented in this report relate only to the item tested.
“(see remark #)” refers to a remark appended to the report.
“(see appended table)” refers to a table appended to the report.
Throughout this report a point is used as the decimal separator.
page 3 of 9
Ref.No.:407363
TRF No.: I60065__C
Copy of marking plates
Note: This test report is also valid for the following models: SUB140/230, SUB146/230, Control Movie
Subwoofer/230, all with brand name
and TSS-450 Subwoofer/230, with brand name
. The
difference between the models is the model name and for the Infinity model also that the green/red LED is
located at the front of the cabinet instead of at the back panel.
page 4 of 9
Ref.No.:407363
IEC 60065
Clause
Requirement - Test
Result - Remark
Verdict
TRF No.: I60065__C
7
HEATING UNDER NORMAL OPERATING CONDITIONS (See appended table)
7.1
Temperature rises not exceeding specified values,
no operation of fuse links
no operation of fuse links
P
7.1.1
Temperature rise of accessible parts
P
7.1.2
Temperature rise of parts providing electrical
insulation
insulation
P
7.1.3
Temperature rise of parts acting as a support or as
a mechanical barrier
a mechanical barrier
P
7.1.4
Temperature rise of windings
P
7.1.5
Parts not subject to a limit under 7.1.1 to 7.1.4
P
7.2
Softening temperature of insulating material
supporting parts conductively connected to the
mains carrying a current > 0.2 A at least 150 ºC
supporting parts conductively connected to the
mains carrying a current > 0.2 A at least 150 ºC
Mains fuse holder
P
11 FAULT
CONDITIONS
(See
appended
table)
11.1
No shock hazard under fault conditions
P
11.2
Heating under fault condition
P
No hazard from softening solder
P
11.2.1
Measurement of temperature rises
P
11.2.2
Temperature rise of accessible parts
P
11.2.3
Temperature rise of parts, other than windings,
providing electrical insulation
providing electrical insulation
P
Temperature rise of printed circuit boards (PCB)
exceeding the limits of Table 2 by max. 100 K for
max. 5 min
exceeding the limits of Table 2 by max. 100 K for
max. 5 min
N
a) Temperature rise of printed circuit boards (PCB)
to 20.1.3, exceeding the limits of Table 2 by not
more than 100 K for an area not greater than
2 cm
to 20.1.3, exceeding the limits of Table 2 by not
more than 100 K for an area not greater than
2 cm
2
N
b) Temperature rise of printed circuit boards (PCB)
to 20.1.3 up to 300 K for an area not greater than
2 cm
to 20.1.3 up to 300 K for an area not greater than
2 cm
2
for a maximum of 5 min
N
Meets all the special conditions if conductors on
printed circuit boards are interrupted
printed circuit boards are interrupted
At Uin=198V, voltage across
interruption <50Vp
At Uin=254.4V, no interruption,
mains fuse broke
interruption <50Vp
At Uin=254.4V, no interruption,
mains fuse broke
(see table 11)
P
11.2.4
Temperature rise of parts acting as a support or
mechanical barrier
mechanical barrier
P
Click on the first or last page to see other SCS 146 Sub (serv.man2) service manuals if exist.