JBL SB 200 (serv.man3) EMC - CB Certificate ▷ View online
Page 53 of 70
Report No.: 350-120155AX
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065K
15.1.1
NO: Mains socket-outlets mounted on CLASS II
apparatus shall comply with the specifications
given in CEE Publ. 7 as far as a applicable, with
the following amendments:
§ 8 Dimensions
a 2.5 A 250 V two-pole socket-outlets for electronic
apparatus shall comply with the enclosed Standard
Sheet I.
apparatus shall comply with the specifications
given in CEE Publ. 7 as far as a applicable, with
the following amendments:
§ 8 Dimensions
a 2.5 A 250 V two-pole socket-outlets for electronic
apparatus shall comply with the enclosed Standard
Sheet I.
§ 24 Mechanical strength
A 2,5 A 250 V socket-outlets for CLASS II
electronic apparatus are tested as specified in
12.1.3 of EN 60065. Also the protecting rim shall be
tested
Justification: Act of 24 May 1929 relating to
supervision of electrical installation (TEA 1929/FEL
1998).
A 2,5 A 250 V socket-outlets for CLASS II
electronic apparatus are tested as specified in
12.1.3 of EN 60065. Also the protecting rim shall be
tested
Justification: Act of 24 May 1929 relating to
supervision of electrical installation (TEA 1929/FEL
1998).
N/A
15.1.1
UK: Apparatus which is fitted with a flexible cable
or cord and is designed to be connected to a mains
socket conforming to BS 1363 by means of that
flexible cable or cord and plug shall be fitted with
a ”standard plug” in accordance with Statutory
Instrument 1768: 1994: The Plugs and Sockets etc.
(Safety) Regulations 1994, unless exempted by
those Regulations.
NOTE ”Standard plug” is defined in SI 1768:1994
and essentially means an approved plug
conforming to BS 1363 or an approved conversion
plug.
Justification: SI 1768: 1994
or cord and is designed to be connected to a mains
socket conforming to BS 1363 by means of that
flexible cable or cord and plug shall be fitted with
a ”standard plug” in accordance with Statutory
Instrument 1768: 1994: The Plugs and Sockets etc.
(Safety) Regulations 1994, unless exempted by
those Regulations.
NOTE ”Standard plug” is defined in SI 1768:1994
and essentially means an approved plug
conforming to BS 1363 or an approved conversion
plug.
Justification: SI 1768: 1994
Pass
Page 54 of 70
Report No.: 350-120155AX
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065K
J.2
NO: After Table J.1 the following is added:
In Norway, due to the IT power distribution system
used, the a.c. MAINS supply voltage is considered
to be equal to the line-to-line voltage, and will
remain 230 V in case of a single earth fault.
Justification: Based on a use in Norway of an IT
power distribution system where the neutral is not
provided.
In Norway, due to the IT power distribution system
used, the a.c. MAINS supply voltage is considered
to be equal to the line-to-line voltage, and will
remain 230 V in case of a single earth fault.
Justification: Based on a use in Norway of an IT
power distribution system where the neutral is not
provided.
N/A
ZC
ANNEX ZC TO EN 60065, A-DEVIATIONS (EN)
-
5.1
IT: Additional markings on the outside of the TV
receiver in Italian language
receiver in Italian language
N/A
IT:User instructions in Italian language including a
conformity declaration
conformity declaration
N/A
IT: Certification number on the back cover
N/A
6.1
N/A
14
SE: Switches containing mercury such as
thermostats, relays and level controllers are not
allowed.
Justification: Ordinance (1990:944) on Prohibition
in Connection with handling. Importation and
exportation of Chemical Products (Certain Cases)
thermostats, relays and level controllers are not
allowed.
Justification: Ordinance (1990:944) on Prohibition
in Connection with handling. Importation and
exportation of Chemical Products (Certain Cases)
N/A
Page 55 of 70
Report No.: 350-120155AX
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065K
ZZ
Australian Deviation (CB Bulletin data base April 26, 2010)
-
7.15
Alternative to the method described in footnote f)
N/A
7.2
Alternative to the method described in footnote h)
N/A
15.1.1
Plugs for the connection of apparatus to mains-
powered socket-outlets shall comply with AS/NZS
3112 or AS/NZS 3123.
powered socket-outlets shall comply with AS/NZS
3112 or AS/NZS 3123.
See appended table CL.14.
Pass
15.3.5
In Table 15, in the second and third rows of the first
column replace ‘6’ with ‘7.5’
column replace ‘6’ with ‘7.5’
Detachable supply cord.
N/A
16.2
In Table 18, in the second and third rows of the first
column replace ‘6’ with ‘7.5’.
column replace ‘6’ with ‘7.5’.
N/A
16.3
A flexible cord complying with AS/NZS 3191 need
not undergo this test.
not undergo this test.
N/A
20.1.4
In Table 21, in the third and fourth columns change
both ‘HB75’ and ‘No requirement’ to ‘V-1’.
both ‘HB75’ and ‘No requirement’ to ‘V-1’.
See appended Table of
CL.14, Material better than V-
1 used.
CL.14, Material better than V-
1 used.
Pass
20.201
Resistance to fire - Alternative tests
N/A
20.201.1
General – “Parts of non-metalic material”
N/A
a) Exemption for components contained in an
enclosure of material V-0 to AS/NZS 60695.11.10
with openings not exceeding 1 mm in width
enclosure of material V-0 to AS/NZS 60695.11.10
with openings not exceeding 1 mm in width
No PIS
N/A
b) Exemption for small components as defined in
20.201.1
20.201.1
N/A
20.201.2
Tests
N/A
20.201.2.1 Testing of non-metalic parts
N/A
Part of non-metallic material shall be subject to the
glow-wire test of AS/NZS 60695.2.11
which shall be carried out at 550°C.
glow-wire test of AS/NZS 60695.2.11
which shall be carried out at 550°C.
N/A
20.201.2.2 Testing of insulated parts
N/A
Part of insulating material supporting
POTENTIAL
IGNITION SOURCES
shall be subject to the glow wire
test of AS/NZS 60695.2.11 which shall be carried
out at 750°C.
The test shall be also carried out on other parts of
insulating material which are within a
distance of 3 mm of the connection.
out at 750°C.
The test shall be also carried out on other parts of
insulating material which are within a
distance of 3 mm of the connection.
N/A
Page 56 of 70
Report No.: 350-120155AX
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065K
For parts which withstand the glow-wire test but
produce a flame, other parts above the
connection within the envelope of a vertical cylinder
having a diameter of 20 mm and a height of 50 mm
shall be subjected to the needle-flame test.
However, parts shielded by a barrier
which meets the needle-flame test need not be
tested.
The needle-flame test shall be made in accordance
with AS/NZS 4695.2.2 with the following
modifications: Clause of AS/NZS 4695.2.2
(“5/Severities”, “8/Test procedure”,
“10/Evaluation of test results”)
produce a flame, other parts above the
connection within the envelope of a vertical cylinder
having a diameter of 20 mm and a height of 50 mm
shall be subjected to the needle-flame test.
However, parts shielded by a barrier
which meets the needle-flame test need not be
tested.
The needle-flame test shall be made in accordance
with AS/NZS 4695.2.2 with the following
modifications: Clause of AS/NZS 4695.2.2
(“5/Severities”, “8/Test procedure”,
“10/Evaluation of test results”)
N/A
The needle-flame test shall not be carried out on
parts of material classified as V-0 or V-1
according to AS/NZS 60695.11.10 provided that
the sample tested was not thicker than the
relevant part.
parts of material classified as V-0 or V-1
according to AS/NZS 60695.11.10 provided that
the sample tested was not thicker than the
relevant part.
N/A
20.201.2.3 Testting by needle-flame test
N/A
If parts, other than enclosures, do not withstand the
glow wire tests of 20.201.2.2, by failure to
extinguish within 30 s after the removal of the glow-
wire tip, the needle-flame test detailed in
20.201.2.2 shall be made on all parts of non-
metallic material which are within a distance of
50 mm or which are likely to be impinged upon by
flame during the tests of 20.201.2.2.
glow wire tests of 20.201.2.2, by failure to
extinguish within 30 s after the removal of the glow-
wire tip, the needle-flame test detailed in
20.201.2.2 shall be made on all parts of non-
metallic material which are within a distance of
50 mm or which are likely to be impinged upon by
flame during the tests of 20.201.2.2.
N/A
20.201.2.4 Testing of printed boards
N/A
Material of printed circuit boards on which the
available power exceeds 15 VA at a voltage
between 50 V and 400 V (peak) a.c. or d.c. meets V-
1 or better to AS/NZS 60695.11.10, unless used in a
fire enclosure
available power exceeds 15 VA at a voltage
between 50 V and 400 V (peak) a.c. or d.c. meets V-
1 or better to AS/NZS 60695.11.10, unless used in a
fire enclosure
N/A
Material of printed circuit boards on which the
available power exceeds 15 VA at a voltage >400 V
(peak) a.c. or d.c. meets V-0 to AS/NZS
60695.11.10
available power exceeds 15 VA at a voltage >400 V
(peak) a.c. or d.c. meets V-0 to AS/NZS
60695.11.10
N/A
21.201.3
For open circuit voltages greater than 4kV
N/A
Potential
ignition
sources
with open circuit voltage
> 4 kV (peak) a.c. or d.c. contained in a fire
enclosure to V-1
enclosure to V-1
N/A
ANNEX B Apparatus to be connected to the
TELECOMMUNICATION NETWORKS
For Australia only, this Annex is replaced by the
requirements of the Telecommunications
Labelling Notice issued under the
Telecommunications Act.
For Australia only, this Annex is replaced by the
requirements of the Telecommunications
Labelling Notice issued under the
Telecommunications Act.
Not connected to
telecommunication network
telecommunication network
N/A