JBL RADIAL (serv.man3) EMC - CB Certificate ▷ View online
Nemko USA, Inc.
11696 Sorrento Valley Road, Suite F, San Diego, CA 92121
Phone (858) 755-5525 Fax (858) 452-1810
DATE
DOCUMENT NAME
DOCUMENT #
PAGE
July 10, 2006
Harman Multimedia JBL Radial CE Test Report
2006 030095-CE Rev1
5 of 50
CERTIFICATION
The compatibility testing and this report have been prepared by Nemko USA, Inc., an independent
electromagnetic compatibility consulting and test laboratory.
The testing and test methods were accomplished in accordance with ETSI EN 301 489-3 V1.4.1 (2002-08),
Norm’s specifications.
I certify the data evaluation and equipment configuration herein to be a true and accurate representation of the
sample's immunity and emission characteristics, as of the test date(s), and for the design of the test sample
utilized to compile this report.
Michael T. Krumweide
EMC Supervisor
EMC Supervisor
Nemko USA, Inc.
11696 Sorrento Valley Road, Suite F, San Diego, CA 92121
Phone (858) 755-5525 Fax (858) 452-1810
DATE
DOCUMENT NAME
DOCUMENT #
PAGE
July 10, 2006
Harman Multimedia JBL Radial CE Test Report
2006 030095-CE Rev1
6 of 50
1. ADMINISTRATIVE DATA AND TEST SUMMARY
1.1. Administrative Data
CLIENT: Harman
Multimedia
CONTACT: Matt
Nelson
DATE (S) OF TEST:
March 28, 2006 to May 3, 2006
EQUIPMENT UNDER TEST (EUT):
Desktop Speaker System
M
ODEL
JBL
Radial
P
ERFORMANCE
C
RITERIA
C
LASSIFICATION
Class
3
C
ONDITION
U
PON
R
ECEIPT
Suitable for Test
TEST SPECIFICATION:
Radio Frequency Emissions and Electromagnetic Immunity
tests in accordance with requirements of EN 301 489-3 V1.4.1
(2002-08) and EN 55022: 1998/A1: 2000/A2: 2003 and EN
55024: 1998/A1: 2001/A2: 2003 as follows:
tests in accordance with requirements of EN 301 489-3 V1.4.1
(2002-08) and EN 55022: 1998/A1: 2000/A2: 2003 and EN
55024: 1998/A1: 2001/A2: 2003 as follows:
Test Type
In Accordance with
Document
Document Title
Conducted and
Radiated Emissions
Radiated Emissions
EN 55022: 1998/A1:
2000/A2: 2003
Class ““B”
2000/A2: 2003
Class ““B”
Specifications for Limits and Methods of Measurement
of Radio Disturbance Characteristics of Information
Technology Equipment (ITE)
of Radio Disturbance Characteristics of Information
Technology Equipment (ITE)
Power Line Harmonics EN 61000-3-2:
2000/A1: 2001/A2:
2005
2005
Electromagnetic Compatibility, Limits for Harmonic
Current Emissions, Equipment Input Current
Current Emissions, Equipment Input Current
less than
or equal to
16A
Power Line Flicker
EN 61000-3-3:
1995/A1: 2001
1995/A1: 2001
Electromagnetic Compatibility, Limitation of Voltage
Fluctuations and Flicker In Low-Voltage Supply
Systems for Equipment with Rated Current
Fluctuations and Flicker In Low-Voltage Supply
Systems for Equipment with Rated Current
less than or
equal to
16A
Electrostatic Discharge
Immunity
Immunity
IEC 61000-4-2:
1995/A1: 1998/A2:
2000
1995/A1: 1998/A2:
2000
Electromagnetic Compatibility for Industrial Process
Measurement and Control Equipment Electrostatic
Discharge Requirements
Measurement and Control Equipment Electrostatic
Discharge Requirements
Radio Frequency
Immunity
Immunity
IEC 61000-4-3: 2006
Electromagnetic Compatibility, Basic Immunity
Standard, Radiated Radio Frequency Electromagnetic
Field, Immunity Test
Standard, Radiated Radio Frequency Electromagnetic
Field, Immunity Test
Electrical Fast
Transient Burst
Immunity
Transient Burst
Immunity
IEC 61000-4-4: 2004
Electromagnetic Compatibility for Industrial Process
Measurement and Control Equipment Electrical Fast
Transient / Burst Requirements
Measurement and Control Equipment Electrical Fast
Transient / Burst Requirements
Nemko USA, Inc.
11696 Sorrento Valley Road, Suite F, San Diego, CA 92121
Phone (858) 755-5525 Fax (858) 452-1810
DATE
DOCUMENT NAME
DOCUMENT #
PAGE
July 10, 2006
Harman Multimedia JBL Radial CE Test Report
2006 030095-CE Rev1
7 of 50
Test Specifications Continued:
Power Line Surge
Immunity
Immunity
IEC 61000-4-5: 2005
Electromagnetic Compatibility, Power Line Surge
Immunity
Immunity
RF Common Mode
Immunity
Immunity
IEC 61000-4-6:
2003/A1: 2004/A2:
2006
2003/A1: 2004/A2:
2006
Electromagnetic Compatibility - Basic Immunity Standard -
Conducted Disturbances Induced By Radio-Frequency
Fields - Immunity Test
Conducted Disturbances Induced By Radio-Frequency
Fields - Immunity Test
Voltage Dips and Short
Interruptions Immunity
Interruptions Immunity
IEC 61000-4-11: 2004
Electromagnetic Compatibility - Testing and Measurement
Techniques - Voltage Dips, Short Interruptions and Voltage
Variations Immunity Tests
Techniques - Voltage Dips, Short Interruptions and Voltage
Variations Immunity Tests
1.2. Test Summary
1.2.1. Emissions Test Summary
Specification
Frequency Range
Compliance Status
EN 55022: 1998/A1: 2000/A2:
2003 , Class “B"
Conducted Emissions
2003 , Class “B"
Conducted Emissions
0.15 MHz – 30 MHz
PASS
EN 55022: 1998/A1: 2000/A2:
2003 , Class “B
Telecom Conducted Emissions
2003 , Class “B
Telecom Conducted Emissions
0.15 MHz – 30 MHz
Not Applicable
EN 55022: 1998/A1: 2000/A2:
2003 , Class “B
Radiated Emissions
2003 , Class “B
Radiated Emissions
30 MHz – 1000 MHz
PASS
EN 61000-3-2: 2000/A1:
2001/A2: 2005
Power Line Harmonics
up to the 40
th
Harmonic
PASS
EN 61000-3-3: 1995/A1: 2001
Power Line Flicker
less than or equal to
4% Maximum Relative
Voltage Change; Value of D(T)
less than or equal
to
3% for more than 200 Ms
PASS
Test Supervisor:
M. Krumweide, Nemko USA, Inc.
Nemko USA, Inc.
11696 Sorrento Valley Road, Suite F, San Diego, CA 92121
Phone (858) 755-5525 Fax (858) 452-1810
DATE
DOCUMENT NAME
DOCUMENT #
PAGE
July 10, 2006
Harman Multimedia JBL Radial CE Test Report
2006 030095-CE Rev1
8 of 50
1.2.2. Immunity Test Summary
Specification
Minimum Criterion
Level Required
as per EN 301 489-3, -1
Criterion Level
Tested
Compliance
Status
IEC 61000-4-2:
1995/A1: 1998/A2:
2000
- ESD Immunity
1995/A1: 1998/A2:
2000
- ESD Immunity
Criterion B
±8 kV air discharge,
±4 kV contact discharge
Criterion B
±8 kV Air Discharge,
±4 kV Contact Discharge
PASS
IEC 61000-4-3: 2006 -
Radio Frequency
Immunity
Immunity
Criterion A
3 V/m from 80-1000 MHz
(80% AM at 1kHz)
Criterion A
3 V/m from 80-1000 MHz
(80% AM at 1kHz)
PASS
IEC 61000-4-4: 2004
-Electrical Fast
-Electrical Fast
Transient Immunity
Criterion B
Power line pulses of ± 1 kV;
I/O line pulses of ± 0.5 kV
Criterion B
Power Line Pulses of ± 1 kV
PASS
IEC 61000-4-5: 2005
Power Line Surge
Power Line Surge
Immunity
Criterion B
Power line pulses of ± 1 kV line
to ground: ± 0.5 kV line to line
Criterion B
Power line pulses of ± 1 kV line
to ground: ± 0.5 kV line to line
PASS
IEC 61000-4-6:
2003/A1: 2004/A2:
2006
-RF Common Mode
2003/A1: 2004/A2:
2006
-RF Common Mode
Immunity
Criterion A
150 kHz - 80 MHz at 3 Vrms
1 kHz 80% amplitude modulated
Criterion A
150 kHz - 80 MHz at 3 Vrms
1kHz 80% amplitude modulated
PASS
IEC 61000-4-11: 2004
- Voltage Dips and
- Voltage Dips and
Short Interruptions
Criterion A and C
Voltage Dips of 30% and 60%;
Interruptions of >95%.
Criterion A and C
Voltage Dips of 30% and 60%;
Interruptions of >95%.
PASS
Test Supervisor:
M. Krumweide, Nemko USA, Inc.
Refer to the test results section for further details.