DOWNLOAD JBL RADIAL (serv.man3) Service Manual ↓ Size: 2.02 MB | Pages: 50 in PDF or view online for FREE

Model
RADIAL (serv.man3)
Pages
50
Size
2.02 MB
Type
PDF
Document
EMC - CB Certificate
Brand
Device
Audio
File
radial-sm3.pdf
Date

JBL RADIAL (serv.man3) EMC - CB Certificate ▷ View online

Nemko USA, Inc. 
11696 Sorrento Valley Road, Suite F, San Diego, CA  92121 
Phone (858) 755-5525  Fax (858) 452-1810 
DATE 
DOCUMENT NAME 
DOCUMENT # 
PAGE 
July 10, 2006 
Harman Multimedia JBL Radial CE Test Report 
2006 030095-CE Rev1 
5 of 50 
 
 
CERTIFICATION 
 
The compatibility testing and this report have been prepared by Nemko USA, Inc., an independent 
electromagnetic compatibility consulting and test laboratory.   
 
The testing and test methods were accomplished in accordance with ETSI EN 301 489-3 V1.4.1 (2002-08), 
Norm’s specifications. 
 
I certify the data evaluation and equipment configuration herein to be a true and accurate representation of the 
sample's immunity and emission characteristics, as of the test date(s), and for the design of the test sample 
utilized to compile this report. 
 
 
 
Michael T. Krumweide 
EMC Supervisor 
 
 
 
Nemko USA, Inc. 
11696 Sorrento Valley Road, Suite F, San Diego, CA  92121 
Phone (858) 755-5525  Fax (858) 452-1810 
DATE 
DOCUMENT NAME 
DOCUMENT # 
PAGE 
July 10, 2006 
Harman Multimedia JBL Radial CE Test Report 
2006 030095-CE Rev1 
6 of 50 
 
1.  ADMINISTRATIVE DATA AND TEST SUMMARY 
1.1. Administrative Data 
 
CLIENT: Harman 
Multimedia 
 
CONTACT: Matt 
Nelson 
 
DATE (S) OF TEST: 
March 28, 2006 to May 3, 2006 
 
EQUIPMENT UNDER TEST (EUT): 
Desktop Speaker System 
 
 
M
ODEL
 JBL 
Radial 
 
P
ERFORMANCE 
C
RITERIA 
C
LASSIFICATION
 Class 
 
C
ONDITION 
U
PON 
R
ECEIPT
 
Suitable for Test 
 
TEST SPECIFICATION: 
Radio Frequency Emissions and Electromagnetic Immunity 
tests in accordance with requirements of EN 301 489-3 V1.4.1 
(2002-08) and EN 55022: 1998/A1: 2000/A2: 2003  and EN 
55024: 1998/A1: 2001/A2: 2003 as follows: 
Test Type 
In Accordance with 
Document 
Document Title 
Conducted and 
Radiated Emissions 
EN 55022: 1998/A1: 
2000/A2: 2003  
Class ““B” 
Specifications for Limits and Methods of Measurement 
of Radio Disturbance Characteristics of Information 
Technology Equipment (ITE) 
Power Line Harmonics   EN 61000-3-2: 
2000/A1: 2001/A2: 
2005  
 
Electromagnetic Compatibility, Limits for Harmonic 
Current Emissions, Equipment Input Current 
less than 
or equal to
 16A 
Power Line Flicker  
EN 61000-3-3: 
1995/A1: 2001  
Electromagnetic Compatibility, Limitation of Voltage 
Fluctuations and Flicker In Low-Voltage Supply 
Systems for Equipment with Rated Current 
less than or 
equal to
 16A 
Electrostatic Discharge 
Immunity 
IEC 61000-4-2: 
1995/A1: 1998/A2: 
2000  
Electromagnetic Compatibility for Industrial Process 
Measurement and Control Equipment Electrostatic 
Discharge Requirements 
Radio Frequency 
Immunity 
IEC 61000-4-3: 2006 
Electromagnetic Compatibility, Basic Immunity 
Standard, Radiated Radio Frequency Electromagnetic 
Field, Immunity Test 
Electrical Fast 
Transient Burst 
Immunity 
IEC 61000-4-4: 2004 
Electromagnetic Compatibility for Industrial Process 
Measurement and Control Equipment Electrical Fast 
Transient / Burst Requirements 
Nemko USA, Inc. 
11696 Sorrento Valley Road, Suite F, San Diego, CA  92121 
Phone (858) 755-5525  Fax (858) 452-1810 
DATE 
DOCUMENT NAME 
DOCUMENT # 
PAGE 
July 10, 2006 
Harman Multimedia JBL Radial CE Test Report 
2006 030095-CE Rev1 
7 of 50 
 
Test Specifications Continued: 
Power Line Surge 
Immunity 
IEC 61000-4-5: 2005 
Electromagnetic Compatibility, Power Line Surge 
Immunity 
RF Common Mode 
Immunity 
IEC 61000-4-6: 
2003/A1: 2004/A2: 
2006 
Electromagnetic Compatibility - Basic Immunity Standard - 
Conducted Disturbances Induced By Radio-Frequency 
Fields - Immunity Test 
Voltage Dips and Short 
Interruptions Immunity 
IEC 61000-4-11: 2004 
Electromagnetic Compatibility - Testing and Measurement 
Techniques - Voltage Dips, Short Interruptions and Voltage 
Variations Immunity Tests 
 
1.2. Test Summary 
1.2.1.  Emissions Test Summary 
 
Specification 
Frequency Range 
Compliance Status 
EN 55022: 1998/A1: 2000/A2: 
2003 , Class “B
Conducted Emissions  
0.15 MHz – 30 MHz  
PASS  
EN 55022: 1998/A1: 2000/A2: 
2003 , Class “B 
Telecom Conducted Emissions  
0.15 MHz – 30 MHz  
Not Applicable 
EN 55022: 1998/A1: 2000/A2: 
2003 , Class “B 
Radiated Emissions  
30 MHz – 1000 MHz  
PASS 
EN 61000-3-2: 2000/A1: 
2001/A2: 2005  
 
Power Line Harmonics 
up to the 40
th
 Harmonic 
PASS 
EN 61000-3-3: 1995/A1: 2001  
Power Line Flicker 
less than or equal to
 4% Maximum Relative 
Voltage Change;  Value of D(T) 
less than or equal 
to
 3% for more than 200 Ms 
PASS
 
 
 
 
Test Supervisor: 
 
M. Krumweide, Nemko USA, Inc. 
Nemko USA, Inc. 
11696 Sorrento Valley Road, Suite F, San Diego, CA  92121 
Phone (858) 755-5525  Fax (858) 452-1810 
DATE 
DOCUMENT NAME 
DOCUMENT # 
PAGE 
July 10, 2006 
Harman Multimedia JBL Radial CE Test Report 
2006 030095-CE Rev1 
8 of 50 
 
 
1.2.2.  Immunity Test Summary 
 
 
Specification 
Minimum Criterion  
Level Required  
as per EN 301 489-3, -1  
 
Criterion Level 
Tested 
Compliance 
Status 
IEC 61000-4-2: 
1995/A1: 1998/A2: 
2000  
- ESD Immunity 
Criterion B 
±8 kV air discharge,  
±4 kV contact discharge 
Criterion B 
±8 kV Air Discharge,  
±4 kV Contact Discharge 
PASS 
IEC 61000-4-3: 2006 -
Radio Frequency 
Immunity 
Criterion A  
3 V/m from 80-1000 MHz  
(80% AM at 1kHz) 
Criterion A  
3 V/m from 80-1000 MHz  
(80% AM at 1kHz) 
PASS 
IEC 61000-4-4: 2004 
-Electrical Fast 
Transient Immunity 
Criterion B 
Power line pulses of ± 1 kV; 
I/O line pulses of ± 0.5 kV 
Criterion B 
Power Line Pulses of ± 1 kV 
 
 
PASS 
IEC 61000-4-5: 2005 
Power Line Surge 
Immunity 
Criterion B 
Power line pulses of ± 1 kV line 
to ground: ± 0.5 kV line to line 
Criterion B 
Power line pulses of ± 1 kV line 
to ground: ± 0.5 kV line to line 
PASS 
IEC 61000-4-6: 
2003/A1: 2004/A2: 
2006 
-RF Common Mode 
Immunity 
Criterion A 
150 kHz - 80 MHz at 3 Vrms 
1 kHz 80% amplitude modulated 
Criterion A 
150 kHz - 80 MHz at 3 Vrms 
1kHz 80% amplitude modulated 
PASS 
IEC 61000-4-11: 2004 
- Voltage Dips and 
Short Interruptions 
Criterion A and C 
Voltage Dips of 30% and 60%; 
Interruptions of >95%. 
Criterion A and C 
Voltage Dips of 30% and 60%; 
Interruptions of >95%. 
PASS 
 
 
 
Test Supervisor
 
M. Krumweide, Nemko USA, Inc. 
Refer to the test results section for further details
Page of 50
Display