July 10, 2006 
Harman Multimedia JBL Radial CE Test Report 
2006 030095-CE Rev1 
33 of 50 
 
4.10. Voltage Dips and Interruptions Immunity Test Results 
Client 
Harman Multimedia 
Temperature 66 
deg 
PAN # 
26-095-HAR 
Relative Humidity 
49 
EUT Name 
Desktop Speaker System 
Barometric Pressure 
29.79  Hg 
EUT Model  
JBL Radial 
Test Location 
West Ground Plane 
Governing Doc 
ETSI EN 301 489-3 
Test Engineer 
A. Laudani 
Basic Standard 
IEC 61000-4-11 
Date 
3-29-06 
 
 
EUT Voltage: 
X  230VAC @ 50Hz 
 
120VAC @ 60Hz 
 
 
 
 
 
 
Equipment Used Used Asset 
# Cal 
Done Cal 
Due 
California Instruments AC Power 
 
604 NCR 
NCR 
Xitron 2520 Standard Impedance 
 
581  
 
EMC System 
845 
3-15-06 
3-15-07 
 
 
 
 
 
 
Changes Occur At: X 
Zero 
Crossing 
   
 
 
 
 
Voltage Dips 
 
 
 
 
Criteria Compliance 
% Reduction Duration 
sec/period 
C Yes No 
   
>95% 
10msec / 0.5 
 
 
 
 
 
  X  30% 
10msec / 0.5 
 
 
 
   
30% 
500msec / 25 
 
 
 
 
 
  X  60% 
100 msec / 5 
 
 
 
   
 
 
 
 
 
 
 
   
 
 
 
 
 
Voltage Interruptions 
 
 
 
 
Criteria Compliance 
% Reduction Duration 
sec/period 
C Yes No 
  X  >95% 
5000msec / 250 
 
 
 
   
100% 
20msec / 1.0 
 
 
 
 
 
   
 
 
 
 
 
 
 
   Not 
Required 
 
 
 
   
 
 
 
  
 
Photo 
 
 
Nemko USA, Inc. 
11696 Sorrento Valley Road, Suite F, San Diego, CA  92121 
Phone (858) 755-5525  Fax (858) 452-1810 
DATE 
DOCUMENT NAME 
DOCUMENT # 
PAGE 
July 10, 2006 
Harman Multimedia JBL Radial CE Test Report 
2006 030095-CE Rev1 
34 of 50 
 
Photograph 2.  Conducted Emissions Test Configuration 
 
 
Nemko USA, Inc. 
11696 Sorrento Valley Road, Suite F, San Diego, CA  92121 
Phone (858) 755-5525  Fax (858) 452-1810 
DATE 
DOCUMENT NAME 
DOCUMENT # 
PAGE 
July 10, 2006 
Harman Multimedia JBL Radial CE Test Report 
2006 030095-CE Rev1 
35 of 50 
 
Photograph 3.  Radiated Emissions Test Configuration 
 
 
 
Nemko USA, Inc. 
11696 Sorrento Valley Road, Suite F, San Diego, CA  92121 
Phone (858) 755-5525  Fax (858) 452-1810 
DATE 
DOCUMENT NAME 
DOCUMENT # 
PAGE 
July 10, 2006 
Harman Multimedia JBL Radial CE Test Report 
2006 030095-CE Rev1 
36 of 50 
 
Photograph 4.  ESD Test Configuration 
 
 