JBL PULSE (serv.man6) EMC - CB Certificate ▷ View online
Page 49 of 51
Report No. 241619
TRF No. IEC60950_1C
5.3
TABLE: Fault condition tests
P
Ambient temperature (
C) ................................... :
25
C if not state.
Power source for EUT: Manufacturer, model/type,
output rating ........................................................ :
output rating ........................................................ :
Component
No.
Fault
Supply
voltage (Vdc)
Test time
Fuse #
Fuse
current
(A)
Observation
Speaker Maximum
non-clipped
5.0
2.3hours
--
--
Unit normal operation, no
damaged, no hazards.
Battery body = 54.0 ºC
PCB under U102= 66.0 ºC.
Ambient: 25.1 ºC
damaged, no hazards.
Battery body = 54.0 ºC
PCB under U102= 66.0 ºC.
Ambient: 25.1 ºC
Speaker S-c 5.0
1.8hours
--
--
Unit normal operation
except speaker shutdown,
no damaged, no hazards.
Battery body = 42.7 ºC
PCB under U102 = 52.8 ºC.
Ambient: 24.9 ºC
except speaker shutdown,
no damaged, no hazards.
Battery body = 42.7 ºC
PCB under U102 = 52.8 ºC.
Ambient: 24.9 ºC
C358
(on main PCB)
(on main PCB)
S-c
5.0
10mins
-- --
Unit shut down. no
damaged. no hazards.
damaged. no hazards.
Battery Over
charging
5.0
7hours
--
--
Unit Normal Operation.
no damaged, no hazards.
Battery body = 34.1 ºC
Ambient: 25.0 ºC
no damaged, no hazards.
Battery body = 34.1 ºC
Ambient: 25.0 ºC
Q1 Pin (1-3)
on battery
PCB
on battery
PCB
S-c
(Over
charging)
5.0
7hours
--
--
Unit Normal Operation.
No hazards,
Battery body = 36.3 ºC
Ambient: 25.0 ºC
No hazards,
Battery body = 36.3 ºC
Ambient: 25.0 ºC
Q2 Pin (1-3)
on battery
PCB
on battery
PCB
S-c
(Over
discharging)
3.7
7hours
--
--
Unit Normal Operation.
No hazards,
Battery body = 52.8 ºC
Ambient: 25.0 ºC
No hazards,
Battery body = 52.8 ºC
Ambient: 25.0 ºC
Battery
(P+ to P-)
(P+ to P-)
S-c
3.7
10mins
-- --
The battery no fire, no
explosion, no leakage. No
hazard.
explosion, no leakage. No
hazard.
On PCB board for battery capacity indication:
D1 S-c
5.0
10mins
-- --
Unit normal operation
except D1 shutdown,
no damaged. no hazards.
except D1 shutdown,
no damaged. no hazards.
D2 S-c
5.0
10mins
-- --
Unit normal operation
except D2 shutdown,
no damaged. no hazards.
except D2 shutdown,
no damaged. no hazards.
D3 S-c
5.0
10mins
-- --
Unit normal operation
except D3 shutdown,
no damaged. no hazards.
except D3 shutdown,
no damaged. no hazards.
Page 50 of 51
Report No. 241619
TRF No. IEC60950_1C
Component
No.
Fault
Supply
voltage (Vdc)
Test time
Fuse #
Fuse
current
(A)
Observation
D4 S-c
5.0
10mins
-- --
Unit normal operation
except D4 shutdown,
no damaged. no hazards.
except D4 shutdown,
no damaged. no hazards.
D5 S-c
5.0
10mins
-- --
Unit normal operation
except D5 shutdown,
no damaged. no hazards.
except D5 shutdown,
no damaged. no hazards.
D6 S-c
5.0
10mins
-- --
Unit normal operation
except D6 shutdown,
no damaged. no hazards.
except D6 shutdown,
no damaged. no hazards.
R9 S-c
5.0
10mins
-- --
Unit normal operation,
no damaged. no hazards.
no damaged. no hazards.
R11 S-c
5.0
10mins
-- --
Unit normal operation,
no damaged. no hazards.
no damaged. no hazards.
R12 S-c
5.0
10mins
-- --
Unit normal operation,
no damaged. no hazards.
no damaged. no hazards.
R13 S-c
5.0
10mins
-- --
Unit normal operation,
no damaged. no hazards.
no damaged. no hazards.
R14 S-c
5.0
10mins
-- --
Unit normal operation,
no damaged. no hazards.
no damaged. no hazards.
R15 S-c
5.0
10mins
-- --
Unit normal operation,
no damaged. no hazards.
no damaged. no hazards.
Q1 pin B-C
S-c
5.0
10mins
-- --
Unit normal operation,
no damaged. no hazards.
no damaged. no hazards.
Q1 pin B-E
S-c
5.0
10mins
-- --
Unit normal operation,
no damaged. no hazards.
no damaged. no hazards.
Q1 pin C-E
S-c
5.0
10mins
-- --
Unit normal operation,
no damaged. no hazards.
no damaged. no hazards.
On PCB board for Bluetooth module and control button:
LED(L1) S-c 5.0
10mins
-- --
Unit normal operation
except L1 shutdown,
no damaged. no hazards.
except L1 shutdown,
no damaged. no hazards.
LED(L2) S-c 5.0
10mins
-- --
Unit normal operation
except L2 shutdown,
no damaged. no hazards.
except L2 shutdown,
no damaged. no hazards.
LED(L2) S-c 5.0
10mins
-- --
Unit normal operation
except L3 shutdown,
no damaged. no hazards.
except L3 shutdown,
no damaged. no hazards.
Supplementary information:
S-c=short circuit.
Page 51 of 51
Report No. 241619
TRF No. IEC60950_1C
C.2 TABLE:
transformer
N/A
Loc.
Tested insulation
Working
voltage
peak / V
(2.10.2)
voltage
peak / V
(2.10.2)
Working
voltage
rms / V
(2.10.2)
voltage
rms / V
(2.10.2)
Required
electric
strength
(5.2)
electric
strength
(5.2)
Required
clearance
/ mm
(2.10.3)
clearance
/ mm
(2.10.3)
Required
creepage
distance /
mm
(2.10.4)
creepage
distance /
mm
(2.10.4)
Required
distance thr.
insul.
(2.10.5)
distance thr.
insul.
(2.10.5)
Loc.
Tested insulation
Test
voltage/
V
voltage/
V
Measured
clearance
/ mm
clearance
/ mm
Measured
creepage
dist./ mm
creepage
dist./ mm
Measured
distance thr.
insul. / mm;
number of
layers
distance thr.
insul. / mm;
number of
layers
supplementary information:
Page 1 of 9
Report No. 241619
Photos
Overall view