1 3
Amplifier/Subwoofer
PSW-D112/DPS-12
3. Low-Pass
    -Set up
Set Generator at 100mV@100Hz
Signal to Low level input
Measure voltage at speaker output
     -Voltage measurement
Low-Pass Pot Setting
Output
CW
12.2V
CCW
1.2V
4. High-Pass
     -Set up
Set Generator at 100mV@100Hz
Signal to Low level input
Measure voltage at high-pass output
     -Voltage measurement
High-Pass Pot Setting
Output
CW
24mV
CCW
55mV
5. Direct out
     -Set up
Set Generator at 100mV@100Hz
Signal to Low level input
     -Voltage measurement 100mV at direct out
See flow chart next page for diagnostics.
1 4
Amplifier/Subwoofer
PSW-D112/DPS-12
PSW-D112/DPS-12 POWER AMP MODULE TESTING FLOW CHART (REV0 ONLY)
JBL Incorporated
250 Crossways Park Dr.
Woodbury, New York 11797 (516) 496-3400
Service Bulletin
Service Bulletin JBL9903 Rev1 - February 2001
This is considered a Minor repair
To:
All JBL Service Centers
Models: PSW-D110, PSW-D112ARC SUB 8, ARC SUB 10
Subject: Check Solder Joints in Event of Failure
Some performance related complaints in the PSW-D110, PSW-D112, ARC SUB 8 or ARC SUB 10 powered
Subwoofers may be caused by cold solder connections between the 28 pins of the Power Amp Module and the
main circuit board. When troubleshooting, failure to check these joints can result in erroneous conclusions or
wasted time.
In the event you receive a PSW-D110, PSW-D112, ARC SUB 8 or ARC SUB 10 Subwoofer with the
complaints “Dead, or No Output, or Motorboating (Oscillation)”, perform the steps listed below first 
before
any further troubleshooting takes place:
1) Unplug all cables, lay the subwoofer on a padded surface.
2) Remove all Philips screws around the outer perimeter of the amplifier faceplate.
3) Remove amplifier assembly; you should be able to remove the amplifier far enough out of the cabinet to service it
without removing the woofer wires.
4) Locate the Power Amp Module; it is the large gray component with a metal case. On the solder side of the circuit
board are the 28 soldered connections to the Module.
5) Regardless of whether you can visibly see breaks in any of the connections or not, carefully re-solder all 28 pin
connections, adding 60/40 rosin core solder. Take care not “bridge” any connections on the board with solder.
6) Inspect the solder joints to the main filter capacitors C1 and C2 on the main PCB and re-solder if needed.
7) Replace the amplifier assembly back into the cabinet; replace the screws.
8) Test the unit by applying a signal from a music source, adjust the volume to a moderate level and confirm the
original problem has been corrected.
IMPORTANT SERVICE NOTES: When testing the PSW-D, or ARC Series amplifier, a load must always be
connected to the output terminals, whether the woofer, or a 4 to 8 ohm resistive load.
All AC powered test instruments (meters, oscilloscopes, etc.) must have a floating ground, i.e. be connected to
an isolation transformer.
15
JBL Incorporated
250 Crossways Park Dr.
Woodbury, New York 11797 (516) 496-3400
Service Bulletin
Service Bulletin JBL2001-02 - February 2001
This is considered a Minor repair
To:
All JBL Service Centers
Models: PSW-D112 rev0*, DPS-12, PSW-D115
Subject: Check Ribbon Cable Connection In Event Of Failure
Some performance related complaints in the PSW-D or DPS Series powered Subwoofers may be caused by
broken or cold solder connections in the ribbon cable connector between the premamp and main PCB.
When this condition occurs, it may also damage the Input Op-Amps U1/U2.
When troubleshooting, failure to check this connector and Input Op-Amps U1/U2 can result in erroneous
conclusions or wasted time.
In the event you receive a PSW-D112*, DPS-12, or PSW-D115 Subwoofer with any of the complaints
“Dead, or No Output, or Motorboating (Oscillation)”, perform the steps listed below before any further
troubleshooting takes place:
1) Unplug all cables, lay the subwoofer on a padded surface.
2) Remove all Philips screws around the outer perimeter of the amplifier faceplate.
3) Remove amplifier assembly; you should be able to remove the amplifier far enough out of the cabinet to service it
without removing other connecting wires.
4) Locate the ribbon cable connector between the premamp PCB and the main PCB. See illustration.
5) Desolder the connection on that cable where the cable attaches to the premamp PCB; to access, you may have to
carefully remove or scrape adhesive from this area.
6) Cut approximately ½” of ribbon from the cable end, then strip enough of the insulator on each of the six conductors
to allow re-connection. Take care not to damage the wire. Solder the cable end back onto the premamp PCB.
7) Test the unit by applying a signal from a music source, adjust the volume to a moderate level and confirm the
original problem has been corrected.
8) If not, troubleshoot Op-Amps U1 and U2 by standard methods; replace if defective:
Make sure plus/minus voltages are present on pins 4 and 11.
Make sure DC voltages are not present at output pins 1,7,8,14. (See schematic)
Apply a signal and confirm there is an output on pins 1,7,8,14. (See schematic)
9) Replace the amplifier assembly back into the cabinet; replace the screws.
* Rev 0 of the PSW-D112 subwoofer is easily identified by the presence of Center channel Input and Output connectors
IMPORTANT SERVICE NOTES: When testing the
PSW-D or DPS Series amplifier, a load must
always be connected to the output terminals,
whether the woofer, or a 4 to 8 ohm resistive load.
All AC powered test instruments (meters,
oscilloscopes, etc.) must have a floating ground,
i.e. be connected to an isolation transformer.