JBL ON TOUR XTB (serv.man8) EMC - CB Certificate ▷ View online
IEC 60950 3rd Ed., 1999.
- Page 5 of 6 -
www.nemko.com
Report No. 111547
Clause
Requirement - Test
Result - Remark
Ver-dict
U.2.1
Replacement:
Electric strength
The test sample is prepared according to IEC 60851-
5:1997, 4.4.1 (for a twisted pair). The sample is then
subjected to the test of 5.2.2 of this standard, with a
test voltage not less than twice the appropriate voltage
in table 5B (see 5.2.2) of this standard. However, the
minimum values shall be as follows:
Electric strength
The test sample is prepared according to IEC 60851-
5:1997, 4.4.1 (for a twisted pair). The sample is then
subjected to the test of 5.2.2 of this standard, with a
test voltage not less than twice the appropriate voltage
in table 5B (see 5.2.2) of this standard. However, the
minimum values shall be as follows:
- for BASIC INSULATION or SUPPLEMENTARY
INSULATION, 3000 V, or;
INSULATION, 3000 V, or;
- for REINFORCED INSULATION, 6000 V.
N/A
U.2.2
Replacement:
Flexibility and adherence
Flexibility and adherence
Test 8 of IEC 60851-3:1996, 5.1.1, using the mandrel
diameters of table U.1. The test sample is then
examined in accordance with IEC 60851-3:1996,
5.1.1.4, followed by the test of 5.2.2 of this standard
except applying the test voltage between the wire and
the mandrel. A test voltage shall not be less than twice
the appropriate voltage in table 5B (see 5.2.2) of this
standard. However, the minimum values shall be as
follows:
diameters of table U.1. The test sample is then
examined in accordance with IEC 60851-3:1996,
5.1.1.4, followed by the test of 5.2.2 of this standard
except applying the test voltage between the wire and
the mandrel. A test voltage shall not be less than twice
the appropriate voltage in table 5B (see 5.2.2) of this
standard. However, the minimum values shall be as
follows:
- for BASIC INSULATION or SUPPLEMENTARY
INSULATION, 1500 V, or;
INSULATION, 1500 V, or;
- for REINFORCED INSULATION, 3000 V.
NOTE: “twice” in the 6
th
line is deleted – ref.
confirmation by Japan NCB – JQA.
N/A
Table U.1
Replacement:
Mandrel diameter
Mandrel diameter
The tension to be applied to the wire during winding on
the mandrel is calculated from the wire diameter to be
equivalent to 118 Mpa ± 10 % (118 N/mm2 ± 10 %).
N/A
U.2.3
Replacement:
Replace the first paragraph with the following.
Test 9 of IEC 60851-6:1996, followed by the electric
strength test of 5.2.2 of this standard except applying
the test voltage between the wire and the mandrel. A
test voltage shall be the appropriate voltage in table 5B
(see 5.2.2) of this standard.
However, the minimum values shall be as follows:
- for BASIC INSULATION or SUPPLEMENTARY
INSULATION, 1500 V, or;
Test 9 of IEC 60851-6:1996, followed by the electric
strength test of 5.2.2 of this standard except applying
the test voltage between the wire and the mandrel. A
test voltage shall be the appropriate voltage in table 5B
(see 5.2.2) of this standard.
However, the minimum values shall be as follows:
- for BASIC INSULATION or SUPPLEMENTARY
INSULATION, 1500 V, or;
for REINFORCED INSULATION 3000 V
N/A
IEC 60950 3rd Ed., 1999.
- Page 6 of 6 -
www.nemko.com
Report No. 111547
Clause
Requirement - Test
Result - Remark
Ver-dict
U.2.4
Replacement:
Replace the third paragraph describing the test voltage
with the following.
The test voltage shall not be less than the appropriate
voltage in table 5B (see 5.2.2) of this standard.
However, the minimum values shall be as follows:
- for BASIC INSULATION or SUPPLEMENTARY
INSULATION, 1500 V, or;
- for REINFORCED INSULATION, 3000 V.
It is applied between the shot and the conductor.
with the following.
The test voltage shall not be less than the appropriate
voltage in table 5B (see 5.2.2) of this standard.
However, the minimum values shall be as follows:
- for BASIC INSULATION or SUPPLEMENTARY
INSULATION, 1500 V, or;
- for REINFORCED INSULATION, 3000 V.
It is applied between the shot and the conductor.
N/A
U.3.1
Replacement:
Replace with the following.
The test voltage for ROUTINE TESTING shall be the
appropriate voltage in table 5B (see 5.2.2) of this
standard. Howeve, the minimum values shall be as
follows:
- for BASIC INSULATION or SUPPLEMENTARY
INSULATION, 1500 V r.m.s. or 2100 V peak, or;
- for REINFORCED INSULATION, 3000 V r.m.s. or
4200 V peak.
The test voltage for ROUTINE TESTING shall be the
appropriate voltage in table 5B (see 5.2.2) of this
standard. Howeve, the minimum values shall be as
follows:
- for BASIC INSULATION or SUPPLEMENTARY
INSULATION, 1500 V r.m.s. or 2100 V peak, or;
- for REINFORCED INSULATION, 3000 V r.m.s. or
4200 V peak.
N/A
U.3.2
Replacement:
Replace with the following.
Twisted pair samples shall be tested in accordance
with IEC 60851-5:1996, 4.4.1. The minimum
breakdown voltage shall not be less than twice the
appropriate voltage in table 5B (see 5.2.2) of this
standard. However, the minimum values shallbe as
follows:
- for BASIC INSULATION or SUPPLEMENTARY
INSULATION, 3000 V r.m.s. or 4200 V peak, or;
- for REINFORCED INSULATION, 6000 V r.m.s. or
8400 V peak.
Twisted pair samples shall be tested in accordance
with IEC 60851-5:1996, 4.4.1. The minimum
breakdown voltage shall not be less than twice the
appropriate voltage in table 5B (see 5.2.2) of this
standard. However, the minimum values shallbe as
follows:
- for BASIC INSULATION or SUPPLEMENTARY
INSULATION, 3000 V r.m.s. or 4200 V peak, or;
- for REINFORCED INSULATION, 6000 V r.m.s. or
8400 V peak.
N/A
IEC 60950-1 (ed.1)
- Page 1 of 1 -
www.nemko.com
Report No. 111547
ATTACHMENT: KOREAN DIFFERENCES
Test results according to CB BULLETIN No. 112A, December 2006
Clause
Requirements – Test
Result – Remark
Verdict
1.5.101 Addition
Plugs for the connection of the apparatus to the
supply mains shall comply with the Korean
requirement (KSC 8305 and 8305).
supply mains shall comply with the Korean
requirement (KSC 8305 and 8305).
Class III equipment.
N/A
7 Addition
EMC
The apparatus shall comply with the relevant
CISPR standards.
The apparatus shall comply with the relevant
CISPR standards.
Must be considered before
marketing in Korea.
marketing in Korea.
N/A
IEC 60950-1 (ed.1)
- Page 1 of 2 -
www.nemko.com
Report No. 111547
ATTACHMENT: SINGAPORE DIFFERENCES
to IEC 60950-1 (ed.1)
No
Item
Requirement
Result - Remark
Verdict
www.safety.org.sg/
, ref. Singapore Consumer Protection (Safety Requirements) - Information
booklet - chapter 7 (page 21 - 24). Based on information by Singapore NCB – PSB Corp.
7 SAFETY AUTHORITY’S REQUIREMENTS
The Safety Authority monitors the safety of the controlled goods sold in Singapore by
investigating all complaints, incidents and accidents reported to the authority. Experiences
gained are translated into the Safety Authority’s Requirements. These requirements are to be
fulfilled in addition to the applicable safety standards.
investigating all complaints, incidents and accidents reported to the authority. Experiences
gained are translated into the Safety Authority’s Requirements. These requirements are to be
fulfilled in addition to the applicable safety standards.
Applicable to all electrical products
2
All appliances
All appliances must be tested to 230
VAC.
VAC.
Class III equipment.
N/A
3
Voltage selector
(voltage mis-match
test)
(voltage mis-match
test)
Appliance fitted with voltage selector
shall be tested as follows:
Connect appliance to 230 VAC
mains with voltage selector switch to
settings not suitable for operation at
230 VAC.
shall be tested as follows:
Connect appliance to 230 VAC
mains with voltage selector switch to
settings not suitable for operation at
230 VAC.
No voltage selector
switch.
switch.
N/A
4
Tropical condition
test
test
All appliances (with tropical test
requirements in applicable
Standards) shall comply with the
tropical condition test as stated in
the relevant IEC Standards.
requirements in applicable
Standards) shall comply with the
tropical condition test as stated in
the relevant IEC Standards.
Equipment contains
functional insulation
only.
functional insulation
only.
N/A
5
Class I appliances
(3-pin mains plug)
All Class I appliances must be fitted
with 3-pin mains plugs
with 3-pin mains plugs
complied
with SS 145/SS 472 that are
registered with the Safety Authority.
registered with the Safety Authority.
Class III equipment.
N/A
6
Class II appliances
(mains plug)
a) All Class II appliances must be
fitted with 2-pin mains plug
(Appendix W) complied with IEC 83:
1975 (Standard C5, Version II) or
EN 50075: 1991.
fitted with 2-pin mains plug
(Appendix W) complied with IEC 83:
1975 (Standard C5, Version II) or
EN 50075: 1991.
b) Class II appliances that are fitted
with 3-pin mains plugs must use
plugs that are complied with SS 145
and registered with the Safety
Authority.
with 3-pin mains plugs must use
plugs that are complied with SS 145
and registered with the Safety
Authority.
Class III equipment.
N/A
7
Appliances rated
≥
3 kW or connected
to fixed wiring
to fixed wiring
Electric appliance
≥ 3 kW must be
connected to fixed wiring. All
connection to fixed wiring must be in
accordance with Code of Practice
CP5.
connection to fixed wiring must be in
accordance with Code of Practice
CP5.
Class III equipment.
N/A