IEC 60950-1 (ed.1)
- Page 4 of 5 -
www.nemko.com
Report No. 111547
The following key national differences are based on requirements other than national regulatory
requirements. The bi-national standard (CAN/CSA C22.2 No. 60950-1/UL 60950-1, First Edition)
should be consulted for further details on the national differences summarized below
requirements. The bi-national standard (CAN/CSA C22.2 No. 60950-1/UL 60950-1, First Edition)
should be consulted for further details on the national differences summarized below
1.5.1
Components of equipment must be suitable for
the application, and must comply with the
requirements of the equipment standard and the
applicable national (Canadian and/or U.S.)
component or material standards, as far as they
may apply.
the application, and must comply with the
requirements of the equipment standard and the
applicable national (Canadian and/or U.S.)
component or material standards, as far as they
may apply.
The acceptance will be based on the following:
I) A component Certified by a Canadian or U.S.
National Certification Body (NCB) to a Canadian
or U.S. component standard will be checked for
correct application and use in accordance with its
specified rating. Where necessary, it will also be
subject to the applicable tests of the equipment
standard.
National Certification Body (NCB) to a Canadian
or U.S. component standard will be checked for
correct application and use in accordance with its
specified rating. Where necessary, it will also be
subject to the applicable tests of the equipment
standard.
J) A component, which has a CB Test Certificate
for compliance with a relevant IEC component
standard, will be checked for correct application
and use in accordance with its specified ratings.
Where necessary, it will also be subject to the
applicable tests of the equipment standard, and
to the applicable tests of the Canadian and/or
U.S. component or material standard, under the
conditions occurring in the equipment.
for compliance with a relevant IEC component
standard, will be checked for correct application
and use in accordance with its specified ratings.
Where necessary, it will also be subject to the
applicable tests of the equipment standard, and
to the applicable tests of the Canadian and/or
U.S. component or material standard, under the
conditions occurring in the equipment.
K) A component, which has no approval as in A)
or B) above or which is used not in accordance
with its specified ratings, will be subject to the
applicable tests of the equipment standard, and
to the applicable tests of the Canadian and/or
U.S. component or material standard, under the
conditions occurring in the equipment.
or B) above or which is used not in accordance
with its specified ratings, will be subject to the
applicable tests of the equipment standard, and
to the applicable tests of the Canadian and/or
U.S. component or material standard, under the
conditions occurring in the equipment.
L) Some components may require annual re-
testing, which may be carried out by the
manufacturer, CSA International or another
laboratory
testing, which may be carried out by the
manufacturer, CSA International or another
laboratory
All critical components are
certified. See appended table
1.5.1 in this report.
certified. See appended table
1.5.1 in this report.
P
2.3.1
For TNV-2 and TNV-3 circuits with other than
ringing signals and with voltages exceeding 42.4
Vp or 60 Vdc, the maximum acceptable current
through a 2000 ohm resistor (or greater)
connected across the voltage source with other
loads disconnected is 7.1 mA peak or 30 mA dc
under normal operating conditions.
ringing signals and with voltages exceeding 42.4
Vp or 60 Vdc, the maximum acceptable current
through a 2000 ohm resistor (or greater)
connected across the voltage source with other
loads disconnected is 7.1 mA peak or 30 mA dc
under normal operating conditions.
TNV not provided.
N/A
2.3.2
In the event of a single fault, the limits of 2.2.3
apply to SELV Circuits and accessible conductive
parts.
apply to SELV Circuits and accessible conductive
parts.
TNV not provided.
N/A
IEC 60950-1 (ed.1)
- Page 5 of 5 -
www.nemko.com
Report No. 111547
2.6.3.4
When subject to impedance testing, protective
earthing and bonding are required to be
subjected to the additional test conditions
specified.
earthing and bonding are required to be
subjected to the additional test conditions
specified.
Class III equipment.
N/A
3.2.1.2
Equipment connected to centralized d.c. power
system, and having one pole of the DC mains
input terminal connected to the main protective
earthing terminal in the equipment, is required to
comply with special earthing, wiring, marking and
installation instruction requirements.
system, and having one pole of the DC mains
input terminal connected to the main protective
earthing terminal in the equipment, is required to
comply with special earthing, wiring, marking and
installation instruction requirements.
Class III equipment, not intended
for connection to DC mains.
for connection to DC mains.
N/A
4.2.8.1
Enclosures around CRT’s with a face diameter of
160 mm or more are required to reduce the risk
of injury due to the implosion of the CRT.
160 mm or more are required to reduce the risk
of injury due to the implosion of the CRT.
No CRTs in the equipment.
N/A
4.3.2
Equipment with handles is required to comply
with special loading tests.
with special loading tests.
No handles.
N/A
5.1.8.3
Equipment intended to receive
telecommunication ringing signals is required to
comply with a special touch current
measurement tests.
telecommunication ringing signals is required to
comply with a special touch current
measurement tests.
No TNV circuitry.
N/A
6.2.1
Enamel coating on winding wire not considered
electrical separation unless subjected to special
investigation.
electrical separation unless subjected to special
investigation.
No TNV circuitry.
N/A
6.4
Equipment intended for connection to
telecommunication network outside plant cable is
required to be protected against overvoltage from
power line crosses in accordance with 6.4 and
Annex NAC.
telecommunication network outside plant cable is
required to be protected against overvoltage from
power line crosses in accordance with 6.4 and
Annex NAC.
No TNV circuitry.
N/A
6.5
Equipment connected to a telecommunications
network and supplied with an earphone intended
to be held against, or in the ear is required to
comply with special acoustic pressure tests.
network and supplied with an earphone intended
to be held against, or in the ear is required to
comply with special acoustic pressure tests.
No TNV circuitry.
N/A
M.2
Continuous ringing signals up to 16 mA only are
permitted if the equipment is subjected to special
installation and performance restrictions.
permitted if the equipment is subjected to special
installation and performance restrictions.
No TNV circuitry.
N/A
IEC 60950 3
rd
Ed.
- Page 1 of 1 -
www.nemko.com
Report No. 111547
ATTACHMENT: CHINESE DIFFERENCES
Test results according to CB BULLETIN No. 112A, December 2006
Clause
Requirement - Test
Result - Remark
Ver-
dict
1.4.5
1.4.5 second paragraph replaced by:
If the equipment is intended for direct
connection to an AC MAINS SUPPLY, the
tolerances on RATED VOLTAGE shall be
taken as +10 % and –10 %,unless:
If the equipment is intended for direct
connection to an AC MAINS SUPPLY, the
tolerances on RATED VOLTAGE shall be
taken as +10 % and –10 %,unless:
Class III equipment.
N/A
1.7.1
1.7.1 fifth paragraph replaced by:
When single rated voltage is given, it should
be marked 220 V; when a rating range is
given, the voltage range shall have a
hyphen (-) between the minimum and
maximum RATED VOLTAGES and should
cover 220 V; When multiple RATED
VOLTAGES or RATED VOLTAGE RANGES
are given, they shall be separated by a solidus
(/) and one of them must be 220 V and also
factory default setting should be 220 V.
RATED FREQUENCY or RATED
FREQUENCY RANGE should be 50Hz or
cover 50Hz, unless the equipment is designed
for d.c.
When single rated voltage is given, it should
be marked 220 V; when a rating range is
given, the voltage range shall have a
hyphen (-) between the minimum and
maximum RATED VOLTAGES and should
cover 220 V; When multiple RATED
VOLTAGES or RATED VOLTAGE RANGES
are given, they shall be separated by a solidus
(/) and one of them must be 220 V and also
factory default setting should be 220 V.
RATED FREQUENCY or RATED
FREQUENCY RANGE should be 50Hz or
cover 50Hz, unless the equipment is designed
for d.c.
only;
Class III equipment.
N/A
1.7.12
1.7.12 replaced by:
Instructions and equipment marking related to
safety shall be written in simplified Chinese in
which the equipment is to be installed.
Instructions and equipment marking related to
safety shall be written in simplified Chinese in
which the equipment is to be installed.
Must be considered before
marketing in China.
marketing in China.
N/A
3.2.1
3.2.1 Add at the end of the first paragraph:
Plugs of apparatus which are intended for the
connection of the mains supply should comply
with requirements of GB1002.
Plugs of apparatus which are intended for the
connection of the mains supply should comply
with requirements of GB1002.
Class III equipment.
N/A
IEC 60950-1 (ed.1)
-
Page
1
of
1
-
www.nemko.com
Report No. 111547
ATTACHMENT: ISRAELI DIFFERENCES
to IEC 60950-1 (ed.1)
Clause
Requirements – Test
Result – Remark
Verdict
1.7.0
Marking and Instructions
The package of the equipment shall be marked in
Hebrew, and shall include:
- The name of the product,
- The name of the manufacturer,
- The country of production,
- The name and the address of the importer.
The marking shall be on a rectangular label (of at
least 52mm x 24mm). The letters height should be
at least 2mm. The color of the label shall be in
contrast to the color of the package.
The package of the equipment shall be marked in
Hebrew, and shall include:
- The name of the product,
- The name of the manufacturer,
- The country of production,
- The name and the address of the importer.
The marking shall be on a rectangular label (of at
least 52mm x 24mm). The letters height should be
at least 2mm. The color of the label shall be in
contrast to the color of the package.
Must be considered before
marketing in Israel.
marketing in Israel.
N/A
1.7.12 Language
All instructions and warnings concerning safety
should be in the Hebrew language as well.
Must be considered before
marketing in Israel.
marketing in Israel.
N/A
2.101 EMC
The equipment shall comply with SI 961 part 6
(CISPR 22 + 24).
Must be considered before
marketing in Israel.
marketing in Israel.
N/A
3.2.1.1
Connection to an a.c. mains supply
Additional note:
In Israel the mains supply plug shall comply with
Israeli standard SI 32.
Additional note:
In Israel the mains supply plug shall comply with
Israeli standard SI 32.
Class III equipment.
N/A