JBL ON TOUR (serv.man6) EMC - CB Certificate ▷ View online
- Page 9 of 17 -
Order No. 23172
1.5.01
LIST OF CRITICAL COMPONENTS
—
Part No
Component/
Object
Object
Manufacturer
Type / Model
Ratings /
Technical Data
Technical Data
Complies
with the
following
standard
with the
following
standard
Marks of
conformity
granted **)
conformity
granted **)
Enclosure
DOW Emerge
4330-22
Rated minimum
flame class HB
flame class HB
UL 94
UL
Alternative
Various
Various
UL 94
UL
Jointronics
PVC
30 V, 80º C
Evaluated
in unit
in unit
UL
Alternative
Various
Various
30 V, 80º C
UL 94
UL
Various
Various
Rated minimum
flame class V -2
flame class V -2
Evaluated
in unit
in unit
UL
PCB material
Various
Various
Rated minimum
flame class V -1 or
better
flame class V -1 or
better
Evaluated
in unit
in unit
UL
Power
amplifier IC
(2)
amplifier IC
(2)
Microsemi
LX1701
2 W x 1 output
Evaluated
in unit
in unit
None
Speaker (2)
Various
1 inch,
magnetically
shielded
magnetically
shielded
6.8
Ω
Evaluated
in unit
in unit
None
Comments
**)
Marks listed under “Marks of conformity granted” indicates Nemko has verified the respective
certifications.
certifications.
- Page 10 of 17 -
Order No. 23172
1.6
POWER INTERFACE
—
1.6.1
A.C. power distribution systems
TN, and IT for Norway.
—
1.6.2
Input current
1 A
—
Test voltage (at each rated voltage
or at each end of a rated voltage
range)
or at each end of a rated voltage
range)
6 VDC
Measured current
Max current during normal operation 0.192 A @ 6 VDC
P
Deviation
Negative deviation is not limited.
P
1.6.3
Voltage limit of hand-held
equipment (max. 250V)
equipment (max. 250V)
The equipment is not hand-held.
N
1.6.4
Neutral conductor
Class III equipment.
P
1.7
MARKINGS AND INSTRUCTIONS
—
1.7.1
Power rating
The required marking is located on the power supply.
P
Rated voltage
6 V (dc symbol from IEC 60417, No. 5031)
Refer to Copy of markings.
Refer to Copy of markings.
P
Symbol for nature of supply for d.c.
Pro vided.
P
Rated frequency or frequency
range
range
Class III equipment.
P
Rated current
1 A
P
Manufacturers name, trade mark or
identification mark
identification mark
—
Type / model
On Tour
P
Symbol of Class II
Class III equipment.
N
Other symbols
The additional marking does not give rise to
misunderstandings.
misunderstandings.
P
Certification marks
Refer to label.
—
1.7.2
Safety instructions
No precautions are necessary.
N
Operating instructions
No instructions necessary.
N
1.7.3
Short duty cycles
The equipment is intended for continuous operation.
N
1.7.4
Supply voltage adjustment
No voltage selector.
N
1.7.5
Power outlets on the equipment
No standard power outlet.
N
1.7.6
Fuse identification
No fusing.
N
1.7.7
Wiring terminals
Class III equipment.
N
- Page 11 of 17 -
Order No. 23172
1.7.8
Controls and indicators
No controls or figures provided.
N
1.7.9
Isolation of multiple power sources
Class III equipment.
N
1.7.10
IT power system
C lass III equipment.
N
1.7.11
Thermostats and other regulating
devices
devices
No adjustable thermostats or other regulating devices.
N
1.7.12
Language
Instructions and equipment marking related to safety
shall be applied in a language, which is acceptable in
the country in which the equipment is to be sold.
shall be applied in a language, which is acceptable in
the country in which the equipment is to be sold.
P
1.7.13
Durability
The marking withstands required tests.
P
1.7.14
Removable parts
No removable parts.
N
1.7.15
Replaceable batteries
No lithium battery in the equipment.
N
1.7.16
Operator access with a tool
Class III equipment.
N
1.7.17
Equipment for restricted access
locations
locations
Equipment not intended for installation in RAL.
N
Copy of the markings:
- Page 12 of 17 -
Order No. 23172
2
PROTECTION FROM HAZARDS
Class III equipment.
N
2.2
SELV CIRCUITS
Class III equipment powered by Limited Power Source.
N
2.3
TNV CIRCUITS
No TNV circuits in the equipment.
N
2.4
LIMITED CURRENT CIRCUITS
No limited current circuits.
N
2.5
LIMITED POWER SOURCES
Limited power source not considered.
N
2.6
PROVISIONS FOR EARTHING
AND BONDING
AND BONDING
Class III equipment.
N
2.7
OVERCURRENT AND EARTH
FAULT PROTECTION IN
PRIMARY CIRCUITS
FAULT PROTECTION IN
PRIMARY CIRCUITS
Class III equipment.
N
2.8
SAFETY INTERLOCKS
2.8.1 – 2.8.8; No safety interlocks.
P
2.9
ELECTRICAL INSULATION
Class III equipment, only Functional insulation used.
N
2.10
CLEARANCES, CREEPAGE
DISTANCES AND DISTANCES
THROUGH INSULATION
DISTANCES AND DISTANCES
THROUGH INSULATION
Class III equipment, only Functional insulation used.
N