JBL ON TOUR (serv.man6) EMC - CB Certificate ▷ View online
- Page 5 of 17 -
Order No. 23172
ADDITIONAL INFORMATION – (continued)
TESTED ACCORDING TO NATIONAL REQUIREMENTS FOR THE FOLLOWING COUNTRIES:
All CENELEC members as listed in EN 60950:2000; all CB mem bers as listed in CB Bulletin 105A,
May 2003 (refer also to page 2).
May 2003 (refer also to page 2).
LIST OF APPENDIXES / ENCLOSURES TO THE TEST REPORT
Appendix EN 60950:2000
10 pages
Australian deviations (including New Zealand)
7 pages
Canadian deviations
5 pages
Chinese deviations
1 page
Israeli deviations
1 page
Japanese deviations
5 pages
Korean deviations
1 page
Singapore deviations
1 page
USA deviations
5 pages
- Page 6 of 17 -
Order No. 23172
PHOTOGRAPHS
Front View Rear View
- Page 7 of 17 -
Order No. 23172
1
GENERAL
—
1.1
SCOPE
—
1.1.1
Equipment covered by this
standard
standard
The product is driven by a digital audio signal and is
therefore considered within the scope of IEC 60950.
therefore considered within the scope of IEC 60950.
—
1.1.2
Additional requirements:
—
Exposure to extreme temperatures,
excessive dust, moisture or
vibration; to flammable gases; to
corrosive or explosive atmospheres
excessive dust, moisture or
vibration; to flammable gases; to
corrosive or explosive atmospheres
This equipment is intended to operate in a "normal"
environment (Offices and homes). Max recommended
ambient temperature (T
environment (Offices and homes). Max recommended
ambient temperature (T
MRA
) as stated by the
manufacturer is 25
°
C.
—
Electromedical equipment
connected to the patient
connected to the patient
This equipment is not an electromedical equipment
intended to be physically connected to a patient.
intended to be physically connected to a patient.
—
Equipment used in vehicles, ships
or aircrafts, in tropical countries, or
at elevations > 2000m
or aircrafts, in tropical countries, or
at elevations > 2000m
This equipment is intended to operate in a "normal"
environment (Offices and homes). Max recommended
ambient temperature (T
environment (Offices and homes). Max recommended
ambient temperature (T
MRA
) as stated by the
manufacturer is 25
°
C.
—
Equipment intended for use where
ingress of water is possible
ingress of water is possible
This equipment is intended to be used in applications
where ingress of water is not regarded possible. The
equipment is non-protected according to IEC 60529.
where ingress of water is not regarded possible. The
equipment is non-protected according to IEC 60529.
—
IP-classification (IEC 60529) (IP)
IP X0.
—
1.2.2
OPERATING CONDITIONS
—
1.2.2.1
Normal load as described in Annex
L or as close as possible to the
most severe normal use
L or as close as possible to the
most severe normal use
Max. undistorted with sign wave signal was 2.05 W,
reduced to 1/8
reduced to 1/8
th
Max. and switched to filtered pink noise
per IEC/EN 60065 for maximum normal load.
Refer to Summary of Testing.
Refer to Summary of Testing.
—
1.2.2.2
Rated operating time as assigned
by the manufacturer
by the manufacturer
The manufacturer has not declared a rated operating
time.
time.
—
1.2.2.3
Continuous operation
The equipment is regarded to be for continuous
operation.
operation.
—
- Page 8 of 17 -
Order No. 23172
1.5
COMPONENTS
—
1.5.1
General
Refer to List of Critical Components.
P
1.5.2
Evaluation and testing of
components
components
Certified components are used in accordance with their
ratings , certifications and they comply with applicable
parts of this standard.
Components not certified are used in accordance with
their ratings and they comply with applicable parts of
IEC 60950 and the relevant component standard.
Components, for which no relevant IEC-standard exists,
have been tested under the conditions occurring in the
equipment, using applicable parts of IEC 60950.
ratings , certifications and they comply with applicable
parts of this standard.
Components not certified are used in accordance with
their ratings and they comply with applicable parts of
IEC 60950 and the relevant component standard.
Components, for which no relevant IEC-standard exists,
have been tested under the conditions occurring in the
equipment, using applicable parts of IEC 60950.
P
Dimensions of mains plug for direct
plug -in equipment
plug -in equipment
Not intended to plug directly into a wall socket-outlet.
N
1.5.3
Thermal controls
No adjustable thermal controls.
N
1.5.4
Transformers
Class III equipment.
N
1.5.5
Interconnecting cables
The interconnecting cables contain only SELV.
N
1.5.6
Capacitors in primary circuits
Class III equipment.
N
1.5.7.1
- 1.5.7.3 Double or reinforced
insulation bridged by components
insulation bridged by components
Class III equipment.
N
1.5.8
Components in equipment for IT
power systems
power systems
Class III equipment.
N