IEC 60950 3rd Ed., 1999. 
- Page 4 of 5 - 
 
 
 
 
Order No.  23172 
 
 
Clause 
Requirement - Test 
Result - Remark 
Ver-
dict  
5.1.6 
Replacement: 
Replace Table 5A. 
 
Class III equipment. 
5.3.8.2 
Replacement: 
Replace 3rd Item as follows. 
- BASIC INSULATION  between the PRIMARY 
CIRCUIT and accessible conductive parts of CLASS I 
or 0I EQUIPMENT; 
Class III equipment. 
Annex A 
Addition: 
Add the subclause A.101 with the title “Flammability 
tests for classifying materials VTM” and the following: 
Thin sheet mater ials shall comply with ISO 9773. 
Considered. 
— 
Annex G 
Addition: 
Add the following to the Note for Table G.1. 
2. In Japan, MAINS TRANSIENT VOLTAGE for 
equipment with a Nominal AC MAINS SUPPLY 
VOLTAGE of 100V is to be decided based on the 
column where Nominal AC MAINS SUPPLY 
VOLTAGE in Table G.1 is 150V. 
Annex G not used 
Annex P 
Addition: 
Add “IEC 61965:2000, Mechanical Safety for Cathode 
Ray Tubes”. 
No CRTs. 
__ 
Annex U 
Replacement: 
Replace 2nd paragraph. 
This annex covers to round winding wires having 
diameters between 0.05 mm and 5.00 mm. 
No TIW used. 
— 
U.2.1 
Replacement: 
Electric strength 
The test sample is prepared according to IEC 60851-
5:1997, 4.4.1 (for a twisted pair). The sample is then 
subjected to the test of 5.2.2 of this standard, with a 
test voltage not less than twice the appropriate voltage 
in table 5B (see 5.2.2) of this standard. However, the 
minimum values shall be as follows: 
- for BASIC INSULATION or SUPPLEMENTARY 
INSULATION, 3000 V, or; 
- for REINFORCED INSULATION, 6000 V.  
No TIW used. 
— 
IEC 60950 3rd Ed., 1999. 
- Page 5 of 5 - 
 
 
 
 
Order No.  23172 
 
 
Clause 
Requirement - Test 
Result - Remark 
Ver-
dict  
U.2.2 
Replacement: 
Flexibility and adherence 
Test 8 of IEC 60851-3:1996, 5.1.1, using the mandrel 
diameters of table U.1. The test sample is then 
examined in accordance with IEC 60851-3:1996, 
5.1.1.4, followed by the test of 5.2.2 of this standard 
except applying the test voltage between the wire and 
the mandrel. A test voltage shall not be less than  twice 
the appropriate voltage in table 5B (see 5.2.2) of this 
standard. However, the minimum values shall be as 
follows: 
- for BASIC INSULATION or SUPPLEMENTARY 
INSULATION, 1500 V, or; 
- for REINFORCED INSULATION, 3000 V.  
NOTE: “twice” in the 6
th
 line is deleted  –  ref. 
confirmation by Japan NCB  – JQA.
 
No TIW used. 
— 
Table U.1 
Replacement: 
Mandrel diameter 
 
The tension to be applied to the wire during winding on 
the mandrel is calculated from the wire diameter to be 
equivalent to 118 Mpa ± 10 % (118 N/mm2 ± 10 %). 
No TIW used. 
— 
IEC 60950 3
rd
 Ed. 
- Page 1 of 1  - 
 
 
 
 
Order No. 
23172
 
 
 
APPENDIX: KOREAN DEVIATIONS 
Test results according to CB BULLETIN No. 105A, May 2003 
 
 
Clause 
Requirement - Test 
Result - Remark 
Ver-
dict  
1.5.101 
Addition: Plugs for the connection of the 
apparatus to the supply mains shall comply 
with the Korean requirement (KSC 8305 and 
8305).  
Must be considered before 
marketing in Korea. 
— 
Addition 
EMC 
The apparatus shall comply with the relevant 
CISPR standards. 
Manufacturer has self-declared 
according to the EMC directive.  
Must be considered before 
marketing in Korea. 
— 
IEC 60950 3rd Ed., 1999  
- Page 1 of 1  - 
 
 
 
 
Order No.  23172 
 
 
APPENDIX: SINGAPORE DEVIATIONS  
Test results according to CB BULLETIN No. 103A, July 2002 
 
 
Clause 
Requirement - Test 
Result - Remark 
Ver-
dict  
The following is the national differences in accordance with SS 337: 2001 based on 
information by Singapore NCB – PSB Corp.
 
1.2.8.6 
After NOTE 2, insert the following: 
NOTE 3 – This definition for SELV CIRCUIT 
differs from the term “SELV system” as given 
in SS CP 5. 
Considered. 
— 
2.9.2 
After the first paragraph, insert the following: 
Under tropical conditions the duration of the 
humidity conditioning is 5 days (120h) at a 
temperature (t) of 40°C 
±
 2°C with a relative 
humidity of 90% to 95%. 
Refer to PSU test report. 
2.10.6.5 
Delete “48h”. 
Considered. 
— 
3.2.8 
Replace “23°C 
±
 2°C by “27°C 
±
 2°C”. 
Considered. 
— 
Attention is also drawn to the following: 
For a.c. power distribution systems, only TN -S  
and TT systems are allowed in the Republic of 
Singapore. 
Class III equipment. 
Where the phrase “this standard” appears, it 
should be read as “Singapore Standard SS 
337”. 
Considered. 
— 
The comma has been used troughout as a 
decimal marker in IEC60950, whereas in 
Singapore standards it is practice to use a  
full-point on the baseline as the decimal 
marker. 
Considered. 
— 
The IEC standards refered to shall be replaced 
by Singapore Standards as follows: 
International  
standard 
IEC 60065 
IEC 60227 
Corresponding 
Singapore Standard 
SS 143 : 2000 
SS 358 : - 
Considered. 
— 
Page of 53