JBL ON STAGEII (serv.man6) EMC - CB Certificate ▷ View online
Nemko USA, Inc.
11696 Sorrento Valley Road, Suite F, San Diego, CA 92121
Phone (858) 755-5525 Fax (858) 452-1810
DATE
DOCUMENT NAME
DOCUMENT #
PAGE
Janurary 5,2006
Harman Multimedia OnStage UD CE Test Report
2006 011114 CE AUS/NZ
49 of 72
4.5. Electrical Fast Transient Burst Immunity Test Results
Client
Harman Multimedia
Temperature 70
deg
F
PAN #
25-1114-HAR
Relative Humidity
49
%
EUT Name
Computer Speaker System
Barometric Pressure
30.5
Hg
EUT Model
OnStage UD
Test Location
Location
Governing Doc
EN 55024
Test Engineer
Test Technician
Basic Standard
IEC 61000-4-4
Date
01/03/06
Test Level:
AC / DC Mains / Control Ports
0.5kV
X 1.0kV
2.0kV
4.0kV
______
Signal
Ports
0.25kV 0.5kV 1.0kV
2.0kV ______
Test Duration:
X 61
sec
_______
Test Equipment
Asset # Used Calibration
Done Calibration
Due
EMC Partner 2000
845
X
10/30/05
02/28/06
Haefely 093 506.1 Clamp
417
NCR
NCR
Haefely FP-EFT Generator 32.1
689
Noiseken FNS-100L
547
Noiseken 15-00001A Clamp
802
NCR
NCR
Performance Criteria:
X A
B
C
Direct Injection Output Path
Test Level
Polarity
(+/-)
L1 L2 PE
Comments
1.0kV
+/-
X
Burst noise heard on speakers during test. Î PASS
1.0kV
+/-
X
Burst noise heard on speakers during test. Î PASS
1.0kV
+/-
X
X
Burst noise heard on speakers during test. Î PASS
Cable Description (Clamp Injection) Polarity
Compliant X
Non-Compliant
Photo
X
Nemko USA, Inc.
11696 Sorrento Valley Road, Suite F, San Diego, CA 92121
Phone (858) 755-5525 Fax (858) 452-1810
DATE
DOCUMENT NAME
DOCUMENT #
PAGE
Janurary 5,2006
Harman Multimedia OnStage UD CE Test Report
2006 011114 CE AUS/NZ
50 of 72
4.6. Power Line Surge Immunity Test Results
Client
Harman Multimedia
Temperature 70
deg
F
PAN #
25-1114-HAR
Relative Humidity
49
%
EUT Name
Computer Speaker System
Barometric Pressure
30.5
Hg
EUT Model
OnStage UD
Test Location
Enclosure 1
Governing Doc
EN 55024
Test Engineer
Rodel Resolme
Basic Standard
IEC 61000-4-5
Date
01/03/06
EUT Power:
Number of Strikes per Polarity/Voltage:
Repetition # Angle
X 230VAC @ 50Hz
X Five (5)
1
0º
230/400VAC @ 50 Hz
Twenty (20)
2
90º
120VAC @ 60 Hz
3
180º
4
270º
5
360º
Waveform Generator Type:
Ring
Wave Combination
Test Equipment: Asset
# Used Calibration
Done Calibration
Due
EMC Partner 2000
845
X
4/15/05
4/15/06
Performance
Criteria: X
A B C
L - Gnd
0.5kV (Level 1)
1.0kV (Level 2)
2.0kV (Level 3)
4.0kV (Level 4)
??kV (Special)
L - L
0.25kV (Level 1)
0.5kV (Level 2)
X 1.0kV (Level 3)
2.0kV (Level 4)
??kV (Special)
Level 1
Level 2
Level 3
Level 4
Special
CM DM CM DM CM DM CM DM CM DM
0.5kV
0.25kV
1.0kV
0.5kV
2.0kV
1.0kV
4.0kV
2.0kV
+ - + - + - + - + - + - + - + - + - + -
N–Gnd
L1–Gnd
N-L1
X X
X X
X X
Compliant X
Non-Compliant
Photo
X
Nemko USA, Inc.
11696 Sorrento Valley Road, Suite F, San Diego, CA 92121
Phone (858) 755-5525 Fax (858) 452-1810
DATE
DOCUMENT NAME
DOCUMENT #
PAGE
Janurary 5,2006
Harman Multimedia OnStage UD CE Test Report
2006 011114 CE AUS/NZ
51 of 72
4.7. RF Conducted Common Mode Disturbance Immunity Test Results
Client
Harman Multimedia
Temperature 70
deg
F
PAN #
25-1114-HAR
Relative Humidity
49
%
EUT Name
Computer Speaker System
Barometric Pressure
30.5
Hg
EUT Model
OnStage UD
Test Location
West Ground Plane
Governing Doc
EN 55024
Test Engineer
Rodel Resolme
Basic Standard
IEC 61000-4-6
Date
01/03/06
Test Level: X
3Vrms
10Vrms
Modulation:
None (CW)
X
80%AM @ 1kHz
Frequency Range: X
0.15 – 80 MHz
0.15-230MHz
Step: X
1%
10%
1.5 x 10¯³ /decade
Performance Criteria: X
A
B
1
Injection Point (Cable) Leader P/S Mains
Injection Method:
Clamp
X CDN
Comments:
2
Injection Point (Cable)
Injection Method:
Clamp
CDN
Comments:
3
Injection Point (Cable)
Injection Method:
Clamp
CDN
Comments:
4
Injection Point (Cable)
Injection Method:
Comments:
5
Injection Point (Cable)
Injection Method:
Comments:
Test Equipment Used
Asset #
X if Used Calibration
Done Calibration
Due
HP 8462B (Signal Generator)
751
X
1/6/05
1/6/06
Fluke 6060B (Signal Generator)
212
HP 8648B (Signal Generator)
746
FCC-801-M1-25 (CDN)
473
FCC-801-M2-25 (CDN)
472
FCC-801-M3-25 (CDN)
466
X
3/14/05
3/14/06
FCC-801-M4-25 (CDN)
628
FCC-801-M5-25 (CDN)
629
FCC-801-T2 (CDN)
626
FCC-801-T4 (CDN)
627
AR 10A250 (Amplifier)
402
NCR
NCR
IFI 1500 (Amplifier)
571
NCR
NCR
RF Power Labs (Amplifier)
397
NCR
NCR
Solar 9144-1N (Clamp)
436
Solar 9121-1N (Clamp)
435
Solar 6741-1N (Clamp)
144
Compliant X
Non-Compliant
Photo X
Nemko USA, Inc.
11696 Sorrento Valley Road, Suite F, San Diego, CA 92121
Phone (858) 755-5525 Fax (858) 452-1810
DATE
DOCUMENT NAME
DOCUMENT #
PAGE
Janurary 5,2006
Harman Multimedia OnStage UD CE Test Report
2006 011114 CE AUS/NZ
52 of 72
4.8. Voltage Dips and Interruptions Immunity Test Results
Client
Harman Multimedia
Temperature 72
deg
F
PAN #
25-1114-HAR
Relative Humidity
48
%
EUT Name
Computer Speaker System
Barometric Pressure
30.5
Hg
EUT Model
OnStage UD
Test Location
West Ground Plane
Governing Doc
EN 55024
Test Engineer
Rodel Resolme
Basic Standard
IEC 61000-4-11
Date
01/04/06
EUT Voltage:
X 230VAC @ 50Hz
120VAC @ 60Hz
Equipment Used Used Asset
# Cal
Done Cal
Due
EMC Partner 2000
X
845 10/30/05
02/28/06
Xitron 2520 Standard Impedance
581
Xitron 2503AH Power Analysis System
582
Changes Occur At: Zero
Crossing
Voltage Dips
Criteria Compliance
% Reduction Duration
sec/period
A
B
C Yes No
X >95%
10msec / 0.5
X
X
30%
10msec / 0.5
X 30%
500msec / 25
X
X
60%
100 msec / 5
Not
Required
Voltage Interruptions
Criteria Compliance
% Reduction Duration
sec/period
A
B
C Yes No
X >95%
5000msec / 250
X
X
100%
20msec / 1.0
Not
Required
Photo
X
Click on the first or last page to see other ON STAGEII (serv.man6) service manuals if exist.