EMC - CB Certificate
Brand
Device
Audio
File
on-call-sm10.pdf
Date

JBL ON CALL (serv.man10) EMC - CB Certificate ▷ View online

 
 
 
 
EMC Report for Harman Model JBL On Call 5310 
File: 3129326LAX-006 
Page 17 of 22 
 
4.3.3 
Disturbance Power Data 
 
Standard: CISPR 13 
 
 
 
 
Measurement Uncertainty: 2.6dB 
Company: Harman Multimedia Consumer Group  
Temperature: 24°C 
Job Number: 3129326LAX-006  
 
 
Relative Humidity: 46% 
Model: JBL On Call 5310 
 
Input power line: 
 
Frequency 
Peak 
AV Limit 
Margin 
MHz 
(dBpW) 
(dBpW) 
(dBpW) 
42.8 
25.6 
36.5 
-10.9 
83.3 
34.7 
39.5 
-4.8 
121.1 
23.3 
41.0 
-17.7 
146.1 
21.0 
41.8 
-20.8 
221.0 
21.9 
43.5 
-21.6 
245.3 
20.8 
43.9 
-23.1 
 
 
Audio In line: 
 
Frequency 
Peak 
AV Limit 
Margin 
MHz 
(dBpW) 
(dBpW) 
(dBpW) 
42.2 
35.8 
36.6 
-0.8 
79.3 
29.8 
39.9 
-10.1 
124.5 
24.3 
41.2 
-16.9 
148.8 
24.3 
41.8 
-17.5 
169.7 
33.6 
42.5 
-8.9 
199.4 
26.4 
43.3 
-16.9 
 
Note :    a)   All other measurements  were more than 20 dB below the limit lines.   
 
 
 b)   A complete scan from 30 - 300 MHz was made. 
 
 c)   Analyzer setting:   RBW  
100 kHz, VBW  
100 kHz 
 
       Detector mode:  
peak 
 
Plots on the next pages show the peak measurement prescans. 
 
 
TEST RESULT: 
EUT PASSED disturbance power test with 0.8 dB margin at 42.2 MHz. 
 
 
 
 
EMC Report for Harman Model JBL On Call 5310 
File: 3129326LAX-006 
Page 18 of 22 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Disturbance Power Prescan – Power Line 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Disturbance Power Prescan – Audio In Line 
 
Intertek Testing Serv ices
Disturbance Power Emissions 30 MHz  - 300 MHz
CISPR 13  (Input line)
30.0M
57.0M
84.0M
111.0M
138.0M
165.0M
192.0M
219.0M
246.0M
273.0M
300.0M
Frequency (Hz)
0
10.0
20.0
30.0
40.0
50.0
60.0
A
m
p
lit
u
d
e
 (
d
B
p
W
)
Company: Harman
Model Number: JBL On Call 5310
04:13:35 PM, Friday, July 20, 2007
Operator: SM
Test Mode: Normal
Cable: Input Line
Test Equipment: IN540, IN548, IN068
Peak Scan
Aver age Limit
Quasi Peak Lim it
Intertek Testing Serv ices
Disturbance Power Emissions 30 MHz  - 300 MHz
CISPR 13  (Power Line)
30.0M
57.0M
84.0M
111.0M
138.0M
165.0M
192.0M
219.0M
246.0M
273.0M
300.0M
Frequency (Hz)
0
10.0
20.0
30.0
40.0
50.0
60.0
A
m
p
lit
u
d
e
 (
d
B
p
W
)
Company: Harman
Model Number: JBL On Call 5310
03:44:50 PM, Friday, July 20, 2007
Operator: SM
Test Mode: Normal
Power: 230 VAC, 50 Hz
Test Equipment: IN540, IN548, IN068
Peak Scan
Aver age Limit
Quasi Peak Lim it
 
 
 
 
EMC Report for Harman Model JBL On Call 5310 
File: 3129326LAX-006 
Page 19 of 22 
 
4.3.4 
Disturbance Power Test Configuration Photograph. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
EMC Report for Harman Model JBL On Call 5310 
File: 3129326LAX-006 
Page 20 of 22 
 
4.4
 
Disturbance Voltage at Antenna Terminal. 
 
4.4.1 Site and Test Description 
 
Testing was performed in accordance with CISPR 13. 
 
When measurements are made at the antenna terminals of the EUT, a signal generator shell be used to feed 
the EUT with a standard test signal.  
 
The Antenna Terminals  of the EUT and the Signal Generator are connected to the measuring receiver by 
means of coaxial cables and the resistive combining network having a minimum attenuation of 6 dB. 
 
The Impedance seen from the EUT shall be equal to the nominal Antenna input impedance for which the 
EUT has been designed. If the output impedance of the signal generator and the input impedance of the 
measuring receiver differ from the value, additional matching network and/or attenuators of minimum value 
of 6 dB shall be inserted. 
 
 
4.4.2 Test Block Diagram: 
 
 
 
 
 
 
 
 
 
 
 
 
 
EUT 
 
Combining 
Network 
Signal Generator 
 
EMI Receiver 
Page of 22