Document
EMC - CB Certificate
Brand
Device
Audio
File
on-call-sm10.pdf
Date

JBL ON CALL (serv.man10) EMC - CB Certificate ▷ View online

 
 
 
 
EMC Report for Harman Model JBL On Call 5310 
File: 3129326LAX-006 
Page 13 of 22 
 
4.2.3 
Conducted Emissions Test Data 
 
Standard: CISPR 13 
 
 
 
 
Measurement Uncertainty: 2.6dB 
Company: Harman Multimedia Consumer Group  
Temperature: 22°C 
Job Number: 3129326LAX-006  
 
 
Relative Humidity: 46% 
Model: JBL On Call 5310 
 
230 VAC 50 Hz: 
Neutral Conductor Measurement: 
 
 
Frequency 
 
Level  (AV) 
 
Limit (AV) 
 
Level (QP) 
 
Limit (QP) 
 
Margin 
 
MHZ 
 
(dBµV) 
 
(dBµV) 
 
(dBµV) 
 
(dBµV) 
 
dB 
0.167 
24.8 
55.4 
43.9 
65.4 
-21.5 
0.369 
36.8 
48.5 
41.2 
58.5 
-11.7 
0.798 
28.9 
46.0 
39.2 
56.0 
-16.8 
2.430 
24.8 
46.0 
36.2 
56.0 
-19.8 
5.600 
37.9 
50.0 
44.2 
60.0 
-12.1 
9.600 
26.3 
50.0 
35.6 
60.0 
-23.7 
 
Line Conductor Measurement:  
 
 
Frequency 
 
Level  (AV) 
 
Limit (AV) 
 
Level (QP) 
 
Limit (QP) 
 
Margin 
 
MHZ 
 
(dBµV) 
 
(dBµV) 
 
(dBµV) 
 
(dBµV) 
 
dB 
0.167 
23.6 
55.4 
44.2 
65.4 
-21.2 
0.369 
36.3 
48.5 
40.5 
58.5 
-12.2 
0.798 
28.3 
46.0 
38.4 
56.0 
-17.6 
2.430 
25.0 
46.0 
37.0 
56.0 
-19.0 
5.550 
37.2 
50.0 
43.7 
60.0 
-12.8 
11.600 
25.4 
50.0 
33.2 
60.0 
-24.6 
 
Note :    a)   All other measurements  were more than 20 dBs below the limit lines.   
 
 b)   A complete scan from 0.15 - 30 MHz was made. 
 c)   Analyzer setting:   RBW  
9 kHz, VBW  
9 kHz 
 
       Detector mode:  
Quasi peak and average 
 
Scans on the next page shows conducted emissions measurements 
 
TEST RESULT: 
EUT PASSED Conducted emissions test with 11.7 dB margin at 0.369 MHz. 
 
 
 
 
 
 
 
 
EMC Report for Harman Model JBL On Call 5310 
File: 3129326LAX-006 
Page 14 of 22 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Conducted Emissions Prescan – Line Conductor 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Conducted Emissions Prescan – Neutral Conductor 
 
Intertek 
Line Conducted Emissions 150 kHz - 30 MHz
CISPR 13 (Neutral)
100.0K
1.0M
10.0M
100.0M
Frequency (Hz)
0
10.0
20.0
30.0
40.0
50.0
60.0
70.0
80.0
A
m
p
lit
u
d
e
 (
d
B
u
V
)
Customer: Harman
Model Number: JBL On Call 5310
04:50:42 PM, Thursday, July 19, 2007
Operator: sm
Mode: Normal, 
Power: 230  VAC, 50 Hz
T C / RH:  22 C / 42%
Peak Scan
Lim it_LC_22B_Av
Lim it_LC_22B_QP
Intertek
Line Conducted Emissions 150 kHz - 30 MHz
CISPR 13 (Line)
100.0K
1.0M
10.0M
100.0M
Frequency (Hz)
0
10.0
20.0
30.0
40.0
50.0
60.0
70.0
80.0
A
m
p
lit
u
d
e
 (
d
B
u
V
)
Customer: Harman
Model Number: JBL On Call 5310
04:48:31 PM, Thursday, July 19, 2007
Operator: sm
Mode: Normal, 
Power: 230  VAC, 50 Hz
T C / RH:  22 C / 42%
Peak Scan
Lim it_LC_22B_Av
Lim it_LC_22B_QP
 
 
 
 
EMC Report for Harman Model JBL On Call 5310 
File: 3129326LAX-006 
Page 15 of 22 
 
4.2.4 
Conducted Emission Test Configuration Photograph 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
EMC Report for Harman Model JBL On Call 5310 
File: 3129326LAX-006 
Page 16 of 22 
 
4.3 
Disturbance Power 
 
4.3.1 
Site and Test Description 
 
Testing was performed in accordance with CISPR 13 
 
The unit was placed on 5.8 m by 6.4m reference ground plane and a power cord was extended to 6 m in 
length and laid in a straight line across a 0.8m high non-conducting support.  An absorbing clamp was 
placed around the power cord and was moved along the lead to determine the maximum value of 
disturbance power. This test was performed on all other leads of length 25 cm or more, measured by means 
of the absorbing clamp. 
 
Initially a scan was made in peak mode from 30 MHz to 300 MHz.  Selected frequencies were identified 
and signals were measured with quasi peak (QP) and average (AV) detectors.  The results were compared 
with the appropriate limits. 
 
 
4.3.2 
Test Limits for CISPR 13 
 
 
Limits of Disturbance power 
 
FREQUENCY 
RANGE (MHz
QP Limits (dBpW) 
AVG Limits (dBpW) 
30 to 300 
45 to 55 
35 to 45 
300 to 1000 
u.c. 
u.c. 
 
U.C. = Under Consideration 
Page of 22
Display