JBL ON BEAT RUMBLE EMC - CB Certificate ▷ View online
Issue Date:
2013-01-09
Page 53 of 54
Report Reference #
E204594-A39-CB-1
IEC 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. : IEC60950_1B
This report issued under the responsibility of UL
non-clipping
power /1KHz)
power /1KHz)
temperature stabillized but
the input current was
decreased to 1.19A
the input current was
decreased to 1.19A
Subwoofer Short-circuit
(deliver 1/8 of
non-clipping
power /100Hz)
non-clipping
power /100Hz)
18V
00h:49m
--
1.18
NT NC
The unit work as normal till
temperature stabillized but
the input current was
decreased to 1.18A
The unit work as normal till
temperature stabillized but
the input current was
decreased to 1.18A
USB port
Overload (pin 1
to 4)
to 4)
18V
Less than 5
s
s
--
--
Measured 5.2 V, max. 7100
mA, R185 damaged
immediately and unit shut
down. NC, NT. (The same
results existed with
replacement of R185 and
test repeated totally 3
times.)
mA, R185 damaged
immediately and unit shut
down. NC, NT. (The same
results existed with
replacement of R185 and
test repeated totally 3
times.)
Iphone
Dock
output
Dock
output
Overload (pin
6,7 to 9,10)
6,7 to 9,10)
18V
--
--
--
Measured 0V / 0A
Iphone
Dock
output
Dock
output
Overload (pin
13,14,15 to
16,17)
13,14,15 to
16,17)
18V
Less than 5
s
s
--
--
Measured 5.2 V, max. 4100
mA, R185 damaged
immediately and unit shut
down. NC, NT. (The same
results existed with
replacement of R185 and
test repeated totally 3
times.)
mA, R185 damaged
immediately and unit shut
down. NC, NT. (The same
results existed with
replacement of R185 and
test repeated totally 3
times.)
C.2
TABLE: transformers
N/A
Loc.
Tested
insulation
insulation
Working
voltage
peak /V
(2.10.2)
voltage
peak /V
(2.10.2)
Working
voltage
rms /V
(2.10.2)
voltage
rms /V
(2.10.2)
Required
electric
strength
(5.2)
electric
strength
(5.2)
Required
clearance /
mm
(2.10.3)
clearance /
mm
(2.10.3)
Required
creepage
distance /
mm
(2.10.4)
creepage
distance /
mm
(2.10.4)
Required
distance
thr. insul.
(2.10.5)
distance
thr. insul.
(2.10.5)
Loc.
Tested insulation
Test
voltage / V
voltage / V
Measured
clearance /
mm
clearance /
mm
Measured
creepage
dist./mm
creepage
dist./mm
Measured
distance
thr. insul /
mm;
number of
layers
distance
thr. insul /
mm;
number of
layers
Issue Date:
2013-01-09
Page 54 of 54
Report Reference #
E204594-A39-CB-1
IEC 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. : IEC60950_1B
This report issued under the responsibility of UL
Transformer type number
Enclosure - Miscellaneous ID
supplementary information:
Issue Date:
2013-01-09
Page 1 of 41
Report Reference #
E204594-A39-CB-1
This report issued under the responsibility of UL
Enclosure
National Differences
Austria**
Belgium**
Bulgaria**
Bulgaria**
China*
Czech Republic**
Denmark
Finland
France**
Germany
Greece**
Group
Hungary**
Ireland
Israel
Italy**
Japan*
Korea
Netherlands**
Norway
Poland**
Portugal**
Romania**
Singapore*
Slovakia**
Slovenia**
Spain
Sweden
Switzerland
USA / Canada
Ukraine*
United Kingdom
*
No National Differences Declared
** Only Group Differences
Issue Date:
2013-01-09
Page 2 of 41
Report Reference #
E204594-A39-CB-1
IEC 60950-1:2005
SubClause Difference + Test
Result - Remark
Verdict
This report issued under the responsibility of UL
Denmark - Differences to IEC 60950-1:2005 (2nd Edition); Am 1:2009
1.2.4.1
In Denmark, certain types of Class I
appliances (see sub-clause 3.2.1.1) may be
provided with plug not establishing earthing
continuity when inserted into Danish socket-outlets.
N/A
1.7.5
In Denmark, socket-outlets for providing
power to other equipment shall be in accordance
with the Heavy Current Regulations, Section 107-2-
D1, Standard Sheet DK 1-3a, DK 1-5a or DK 1-7a,
when used on Class I equipment. For stationary
equipment, the socket-outlet shall be in accordance
with Standard Sheet DK 1-1b or DK 1-5a.
N/A
1.7.5
For CLASS II EQUIPMENT the socket
outlet shall be in accordance with Standard Sheet
DKA 1-4a. (Heavy Current Regulations, Section
107-2-D1)
N/A
3.2.1.1
Supply cord of single-phase equipment
having a rated current not exceeding 13 A shall be
provided with a plug according to the Heavy
Current Regulations, Section 107-2-D1.
CLASS I EQUIPMENT provided with socket-outlets
with earth contact or which are intended to be used
in locations where protection against indirect
contact is required according to the wiring rules
shall be provided with a plug in accordance with
standard sheet DK 2-1a or DK 2-5a.
If poly-phase equipment and single-phase
equipment having a RATED CURRENT exceeding
13 A is provided with a supply cord with a plug, this
plug shall be in accordance with the Heavy Current
Regulations, Section 107-2-D1 or EN 60309-2.
N/A