ATTACHMENT
 
 
National Differences 
 
 
Page 68 of 116 
 
Report No.: 11023927 001 
 
I
 TRF No. IEC60950_1B 
National Differences 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
6.1.2.1 
In FinlandNorway and Sweden, add the 
following text between the first and second 
paragraph of the compliance clause: 
If this insulation is solid, including insulation 
forming part of a component, it shall at least 
consist of either 
two layers of thin sheet material, each of 
which shall pass the electric  
 
strength test below, or 
one layer having a distance through 
insulation of at least 0,4 mm, which shall  
 
pass the electric strength test below. 
If this insulation forms part of a semiconductor 
component (e.g. an optocoupler), there is no 
distance through insulation requirement for the 
insulation consisting of an insulating compound 
completely filling the casing, so that 
CLEARANCES and CREEPAGE DISTANCES do 
not exist, if the component passes the electric 
strength test in accordance with the compliance 
clause below and in addition 
passes the tests and inspection criteria of 
2.10.11 with an electric strength  
 
test of 1,5 kV multiplied by 1,6 (the electric 
strength test of 2.10.10 shall be  
 
performed using 1,5 kV), and 
is subject to ROUTINE TESTING for electric 
strength during manufacturing,  
 
using a test voltage of 1,5 kV. 
It is permitted to bridge this insulation with a 
capacitor complying with EN 132400:1994, 
subclass Y2. 
A capacitor classified Y3 according to EN 
132400:1994, may bridge this insulation under the 
following conditions: 
the insulation requirements are satisfied by 
having a capacitor classified Y3  
 
as defined by EN 132400, which in addition 
to the Y3 testing, is tested with  
 
an impulse test of 2,5 kV defined in EN 
60950-1:2006, 6.2.2.1; 
the additional testing shall be performed on 
all the test specimens as  
 
described in EN 132400; 
the impulse test of 2,5 kV is to be performed 
before the endurance test in EN 132400, in the 
sequence of tests as described in EN 132400. 
No TNV. 
N/A 
 
 
ATTACHMENT
 
 
National Differences 
 
 
Page 69 of 116 
 
Report No.: 11023927 001 
 
I
 TRF No. IEC60950_1B 
National Differences 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
6.1.2.2 
In FinlandNorway and Sweden, the exclusions 
are applicable for PERMANENTLY CONNECTED 
EQUIPMENT, PLUGGABLE EQUIPMENT TYPE B 
and equipment intended to be used in a 
RESTRICTED ACCESS LOCATION where 
equipotential bonding has been applied, e.g. in a 
telecommunication centre, and which has provision 
for a permanently connected PROTECTIVE 
EARTHING CONDUCTOR and is provided with 
instructions for the installation of that conductor by 
a SERVICE PERSON. 
No TNV. 
N/A 
7.2 
In FinlandNorway and Sweden, for requirements 
see 6.1.2.1 and 6.1.2.2 of this annex. 
The term TELECOMMUNICATION NETWORK in 
6.1.2 being replaced by the term CABLE 
DISTRIBUTION SYSTEM. 
Not connected to cable 
distribution system. 
N/A 
7.3 
In Norway and Sweden, there are many buildings 
where the shielding of the coaxial cable is normally 
not connected to the earth in the building 
installation. 
Not connected to cable 
distribution system. 
N/A 
7.3 
In Norway, for installation conditions see EN 
60728-11:2005. 
Not connected to cable 
distribution system. 
N/A 
 
ZC 
A-DEVIATIONS (informative) 
1.5.1 
Sweden (Ordinance 1990:944) 
Add the following: 
NOTE In Sweden, switches containing mercury are 
not permitted. 
No switch provided. 
N/A 
1.5.1 
Switzerland (Ordinance on environmentally 
hazardous substances SR 814.081, Annex 1.7, 
Mercury - Annex 1.7 of SR 814.81 applies for 
mercury.) 
Add the following: 
NOTE In Switzerland, switches containing mercury 
such as thermostats, relays and level controllers 
are not allowed. 
No switch provided. 
N/A 
 
 
ATTACHMENT
 
 
National Differences 
 
 
Page 70 of 116 
 
Report No.: 11023927 001 
 
I
 TRF No. IEC60950_1B 
National Differences 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
1.7.2.1 
Denmark (Heavy Current Regulations) 
Supply cords of CLASS I EQUIPMENT, which is 
delivered without a plug, must be provided with a 
visible tag with the following text: 
Vigtigt! 
Lederen med grøn/gul isolation 
må kun tilsluttes en klemme mærket 
 eller 
 
If essential for the safety of the equipment, the tag 
must in addition be provided with a diagram, which 
shows the connection of the other conductors, or 
be provided with the following text: 
“For tilslutning af de øvrige ledere, se medfølgende 
installationsvejledning.” 
N/A 
1.7.2.1 
Germany (Gesetz über technische Arbeitsmittel 
und Verbraucherprodukte (Geräte- und 
Produktsicherheitsgesetz – GPSG) [Law on 
technical labour equipment and consumer 
products], of 6th January 2004, Section 2, Article 4, 
Clause (4), Item 2). 
If for the assurance of safety and health certain 
rules during use, amending or maintenance of a 
technical labour equipment or readymade 
consumer product are to be followed, a manual in 
German language has to be delivered when 
placing the product on the market. 
Of this requirement, rules for use even only by 
SERVICE PERSONS are not exempted. 
Switching power supply, and 
German instruction sheet 
provided. 
1.7.5 
Denmark (Heavy Current Regulations) 
With the exception of CLASS II EQUIPMENT 
provided with a socket outlet in accordance with 
the Heavy Current Regulations, Section 107-2-D1, 
Standard Sheet DK 1-4a, CLASS II EQUIPMENT 
shall not be fitted with socket-outlets for providing 
power to other equipment. 
No socket-outlet provided. 
N/A 
1.7.13 
Switzerland (Ordinance on chemical hazardous 
risk reduction SR 814.81, Annex 2.15 Batteries) 
Annex 2.15 of SR 814.81 applies for batteries. 
No battery provided. 
N/A 
5.1.7.1 
Denmark (Heavy Current Regulations, Chapter 
707, clause 707.4) 
TOUCH CURRENT measurement results 
exceeding 3,5 mA r.m.s. are permitted only for 
PERMANENTLY CONNECTED EQUIPMENT and 
PLUGGABLE EQUIPMENT TYPE B. 
 
N/A 
 
 
 
ATTACHMENT
 
 
National Differences 
 
 
Page 71 of 116 
 
Report No.: 11023927 001 
 
I
 TRF No. IEC60950_1B 
National Differences 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
 
 
 
          Annex ZA (Modified by A11:2009) 
Normative references to international publications 
 