Page 46 of 48 
Report No. 806700 
 IEC 
60065
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
 
TRF No.: IEC60065F 
 
TRF Originator: ASTA BEAB 
 
National differences SINGAPORE 
IEC 60065:2001 
NOTE: (These differences are taken from IEC 60065:1993 and adopted to  
IEC 60065:2001) 
 CB / SG  2006  II
 
 
Throughout the standard,
 whenever the words 
"white pine board" appear, insert the words "or 
plywood board" to it. 
 P 
 
SS143 Amendment No. 1 and No. 2 
 
4.1.3 
(4.1.3)* 
Delete "45 % to 75 % and insert "65 ± 5 %". 
75% maximum in IEC 
60065:2001 
7.1 
(7.1) 
Resistance to heat without external forces. 
Adopt the temperature specified for the tropical 
conditions. 
 P 
8.6 
(9.3.4) 
Delete the note "A Quality Assessment System 
for capacitors complying with Subclause 14.2 is 
under consideration in the IEC". 
This is not in IEC 60065:2001 
10.2 
(10.2) 
Humidity treatment 
Adopt the testing conditions designed for tropical 
conditions. 
 
120h at 93% relatively 
humidity 
16 
(16) 
External flexible cords 
Delete "IEC Publication 60227: Polyvinyl Chloride 
Insulated Cables of Rated Voltages up to and 
Including 450/750 V and IEC publication 60245: 
Rubber insulated Cables of rated up to and 
including 450/750 V " and insert "Singapore 
Standard 236: Flexible Cords", whenever they 
appear in this clause. 
Delete "CEE Publication 13, CEE Publication 2 
and IEC Publication 60173: Colours of the Cores 
of Flexible Cables and Cords" whenever they 
appear in this clause. 
 P 
16.2 
(16.2) 
Delete the notes in small print and insert "A 
nominal cross-sectional area of 0.75 mm² will 
satisfy this requirement". 
This is not in IEC 60065:2001 
 
Page 47 of 48 
Report No. 806700 
 IEC 
60065
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
 
TRF No.: IEC60065F 
 
TRF Originator: ASTA BEAB 
16.3b 
(16.4b) 
Delete “Subclause 3.1 of IEC Publication 
60227-2: Part 2: Test Methods“ and insert 
“Subclause 9.1 of SS 236“: 
9.1 Flexing test (except for tinsel cords, twisted 
twin and single core cords). The test shall be 
carried out by means of the apparatus shown in 
Figure 5. This apparatus has a carrier C 
supporting two pulleys A and B arranged so that 
the cord is horizontal between the pulleys. The 
carrier moves backward and forward over a 
distance of 1 m at an approximately constant 
speed of 0.33 m/s. 
A sample of flexible cord about 5 m long shall be 
stretched over the pulleys as shown in the figure, 
each end being loaded with a weight. The weight 
and the diameter of the pulleys A and B shall be 
given in Table 1. 
Screen cords in accordance with Table 7 shall be 
tested before application of the screen and outer 
sheath. 
The pulleys shall have a semi-circular shaped 
groove for circular cords and a flat groove for 
parallel twin cords. The restraining clamps D shall 
be fixed so that the pull is always applied by the 
weight from which the carrier is moving away. 
The carrier shall make 30 000 backward and 
forward movements (60 000 single strokes). Each 
conductor of the sample shall be loaded with the 
current specified in Table 2. 
For twin cords and for light PVC-sheated 3-core 
cords, the voltage between the conductors shall 
be approximately 230 V a.c. For all other cords 
having three or more cores a three-phase a.c. 
voltage of about 400 V shall be applied to three 
conductors, any additional conductors being 
connected to the neutral. 
During the test no open-circuit in any core or 
short-circuit between cores shall occur. 
After the test, any sheath on cords having three 
or more cores shall be removed. The cord, or the 
laid up cores, shall then withstand the voltage test 
specified in Subclause 8.2 or 8.3 as appropriate, 
but with a test voltage not exceeding 2000 V. 
TABLE 1, TABLE 2, FIGURES 4 and  5, see the 
CB BULLETIN 
 P 
* in parenthesis: clauses acc. to IEC 60065:1993 
 
 
Page 48 of 48 
Report No. 806700 
 IEC 
60065
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
 
TRF No.: IEC60065F 
 
TRF Originator: ASTA BEAB 
 
National differences Korea 
IEC 60065:2001  
Information from Korea / KR  06  I I
 
 
 
National supply voltage are 110,220 and 380V 
 
 
Only appliances having supply frequency of 
60Hz or a frequency range including 60Hz are 
accepted 
 
Instruction manuals and marking related safety, 
including name plate shall be in Korean or 
graphical symbols in accordance with IEC 
Publication 417. 
 P 
5.101 Addition 
Other marking; 
Wording “            “ ( See the CB Bulletine) or an 
information regulated in IEC Publication 60417 
giving high voltage warning to layman shall be 
marked, if an apparatus contains a part more 
than 600 volts. 
 
N/A 
15.1.1 
Plugs for the connection of the apparatus to the 
supply mains and socket outlets for providing 
mains power to other apparatus shall comply with 
the Korean requirements (KSC 8300 and 8305). 
 P 
31 
Radio frequency Interference 
The apparatus shall comply with the relevant 
CISPR requirements. (EMC=EMI + EMS) 
Not checked 
N/A 
 
 
 
 
 
Page 1 of 10 
 
806700 (ES150PW/230) 
 
 
806700 (ES150PW/230) 
 
Page of 63
Display