DOWNLOAD JBL ES 150PW Service Manual ↓ Size: 7.42 MB | Pages: 63 in PDF or view online for FREE

Model
ES 150PW
Pages
63
Size
7.42 MB
Type
PDF
Document
EMC - CB Certificate
Brand
Device
Audio
File
es-150pw.pdf
Date

JBL ES 150PW EMC - CB Certificate ▷ View online

 
Page 10 of 48 
Report No. 806700 
 IEC 
60065
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
 
TRF No.: IEC60065F 
 
TRF Originator: ASTA BEAB 
9.1.3 
Ventilation holes tested by means of 
4 mm x 100 mm test pin 
 N/A 
9.1.4 
Terminal devices - within 25mm tested with 
1 mm x 20 mm test pin (10 N); test probe D of IEC 
61032 
 P 
 
Terminal devices tested with 1 mm x 100 mm 
straight wire (1 N); test probe D of IEC 61032 
 P 
9.1.5 
Pre-set controls tested with 2.5 mm x 100 mm test 
pin (10 N); test probe C of IEC 61032 
 N/A 
9.1.6 
No shock hazard due to stored charge on 
withdrawal of the mains plug; voltage (V) after 2 s  : 
<5V P 
 
If C is not greater than 0.1 μF no test needed 
 
N/A 
9.1.7 
Enclosure sufficiently resistant to external force 
a) 
Test probe 11 of IEC 61032 for 10 s (50 N) 
 
b) 
Test hook of fig. 4 for 10 s (20 N) 
 
c) 
Conductive enclosure: 30 mm diameter test tool for 
5 s (100 or 250 N) ...................................................: 
250N P 
9.2 
No hazard 2s after removing a cover by hand 
 
N/A 
 
 
10 INSULATION 
REQUIREMENTS 
10.1 
Insulation resistance (MΩ) at least 2 MΩ min. after 
surge test for basic and 4 MΩ min. for reinforced 
insulation .................................................................: 
 N/A 
10.2 
Humidity treatment 48 h or 120 h ...........................:  48h and 120h 
10.3 
Insulation resistance and dielectric strength 
between mains terminals 
 P 
 
Insulation resistance and dielectric strength across 
BASIC or SUPPLEMENTARY insulation (Class 1) 
 P 
 
Insulation resistance across REINFORCED 
insulation (Class II) 
 P 
 
 
11 FAULT 
CONDITIONS 
11.1 
No shock hazard under fault condition 
 
11.2 
Heating under fault condition 
 
 
No hazard from softening solder 
 
 
No flaming more than 10s 
 
 
Soldered terminations not used as protective 
mechanism 
 P 
 
Page 11 of 48 
Report No. 806700 
 IEC 
60065
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
 
TRF No.: IEC60065F 
 
TRF Originator: ASTA BEAB 
11.2.1 
Measurement of temperature rises 
 
11.2.2 
Temperature rise of accessible parts 
 
11.2.3 
Temperature rise of parts, other than windings, 
providing electrical insulation 
 P 
 
Temperature rise of printed circuit boards (PCB) 
exceeding the limits of table 3 by max. 100 K for 
max. 5 min 
 N/A 
 
a) Temperature rise of printed circuit boards (PCB) 
to 20.1.3, exceeding the limits of table 3 by not more 
than 100 K for an area not greater than 2 cm² 
 N/A 
 
b) Temperature rise of printed circuit boards (PCB) 
to 20.1.3 up to 300 K for an area not greater than 
2 cm² for a maximum of 5 min 
 N/A 
 
Meets all the special conditions if conductors on 
printed circuit boards are interrupted 
 N/A 
 
Class I protective earthing maintained 
 
N/A 
11.2.4 
Temperature rise of parts acting as a support or 
mechanical barrier 
 P 
11.2.5 
Temperature rise of windings 
 
11.2.6 
Temperature rise of parts not subject to the limits of 
11.2.1 to 11.2.5 Table 3 e) "Other Parts" 
 P 
 
 
12 MECHANICAL 
STRENGTH 
12.1.1 
Bump test where mass >7 kg 
15.5kg 
12.1.2 
Vibration test (portable, metal, musical amps) 
No connection or part that might 
impair safety can become loose
12.1.3 
Impact hammer test  
 
 
Steel ball test (for non-ventilated solid areas) 
 
12.1.4 
Drop test for portable apparatus where mass ≤ 7 kg   
N/A 
12.1.5 
Thermoplastic enclosures stress relief test 
 
12.2 
Fixing of knobs, push buttons, keys and levers 
 
12.3 
Remote controls with hazardous live parts 
 
N/A 
12.4 
Drawers (pull test 50 N, 10 s) 
 
N/A 
12.5 
Antenna coaxial sockets providing isolation 
 
N/A 
12.6 
Telescoping or rod antennas construction 
Antenna ball end Ø=7.5mm  
12.6.1 
Telescoping or rod antennas securement 
20N 
 
 
Page 12 of 48 
Report No. 806700 
 IEC 
60065
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
 
TRF No.: IEC60065F 
 
TRF Originator: ASTA BEAB 
13 
CLEARANCE AND CREEPAGE DISTANCES 
(See appended table 13) 
13.1 
Clearances in accordance with 13.3 
 
 
Creepage distances in accordance with 13.4 
 
13.2 
Determination of operating voltage 
 
13.3 
Clearances 
 
 
13.3.2 
Circuits conductively connected to the mains 
comply with table 8 and, where applicable, table 9 
 P 
13.3.3 
Circuits not conductively connected to the mains 
comply with table 10 
Circuits not conductively 
connected to the mains cannot 
cause any shock hazard 
N/A 
13.3.4 
Measurement of transient voltages 
 
N/A 
13.4 
Creepage distances 
 
Creepage distances greater than table 11 minima 
 
13.5 
Printed boards 
13.5.1 
Clearances and creepage distances between 
conductors on printed circuit boards, one of which 
may be conductively connected to the mains, as in 
fig. 10 
 N/A 
13.5.2 
Type B coated printed circuit boards complying with 
IEC 60664-3 (basic insulation only) 
 N/A 
13.6 
Conductive parts along uncemented joints 
clearances and creepage distances comply with 
13.3 and 13.4 
 N/A 
 
Conductive parts along reliably cemented joints 
comply with 8.8 
 N/A 
13.7 
Enclosed, enveloped or hermetically sealed parts: 
not conductively connected to the mains: 
clearances and creepage distances as in table 12 
 N/A 
13.8 
Parts filled with insulating compound, meeting the 
requirements of 8.8 
 N/A 
 
 
Page 13 of 48 
Report No. 806700 
 IEC 
60065
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
 
TRF No.: IEC60065F 
 
TRF Originator: ASTA BEAB 
14 COMPONENTS 
14.1 
Resistors 
 
a) Resistors between hazardous live parts and 
accessible metal parts 
 N/A 
 
b) Resistors, other than between hazardous live 
parts and accessible parts 
 N/A 
 Resistors 
separately approved ...............................:   
N/A 
14.2 
Capacitors and RC units 
 
Capacitors separately approved 
Yes 
14.2.1 
Y capacitors tested to IEC 60384-14, 2
nd
 edition ...:  Y1: C03, C04 
14.2.2 
X capacitors tested to IEC 60384-14, 2
nd
 edition ...:  X2: C01, C02 
14.2.3 
Capacitors operating at mains frequency but not 
connected to the mains: tests for X2 ......................: 
 N/A 
14.2.5     a)  Capacitors with volume exceeding 1750 mm³, 
where short-circuit current exceeds 0.2 A: 
compliance with IEC 60384-1, 4.38 category B or 
better .......................................................................: 
C01, C02 
b) 
Capacitors with volume exceeding 1750 mm³, 
mounted closer to a potential ignition source than 
table 5 permits: compliance with IEC 60384-1, 4.38 
category B or better  ................................................: 
Only metal-cased capacitors 
N/A 
 
Shielded by a barrier per Table 21..........................: No 
N/A 
14.3 
Inductors and windings 
 
Comply with IEC 61558-1, IEC 61558-2 
(as relevant) and clause 20.1.4 
 P 
14.3.1 
Transformers and inductors marked with 
manufacturer's name and type ...............................: 
Zhong Shan Yi Qi 
150-R0905504-E 
 
Transformers and inductors separately approved .:  No 
N/A 
14.3.2 
General 
14.3.3, 14.3.4.1 and 14.3.5.1 
14.3.3 
Constructional requirements (complete appended tables or include manufacturers 
constructional insulation descriptions) 
14.3.3.1 
Clearances and creepage distances comply with 
clause 13 
 P 
14.3.3.2 Transformers 
meet 
the 
constructional requirements   
14.3.4.1 
Class II transformers have adequate separation 
between hazardous live parts and accessible parts 
(double or reinforced insulation) 
Primary – secondary: 9.8mm 
 
Coil formers and partition walls = 0.4 mm 
Thin sheet insulation 
Page of 63
Display