JBL DUET II (serv.man3) EMC - CB Certificate ▷ View online
- Page 29 of 65 -
Report
No.
114383
IEC 60950-1:2005 / EN 60950-1:2006
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IECEN60950_1C
4.7.2.2
Parts not requiring a fire enclosure
Equipment is class III powered
from a LPS. Additionally all
components are mounted on V-
1 or better material.
from a LPS. Additionally all
components are mounted on V-
1 or better material.
P
4.7.3 Materials
⎯
4.7.3.1
General
Components and materials
have adequate flammability
classification. See appended
table 1.5.1.
have adequate flammability
classification. See appended
table 1.5.1.
P
4.7.3.2
Materials for fire enclosures
Fire enclosure not required,
refer to 4.7.2.
refer to 4.7.2.
N
4.7.3.3
Materials for components and other parts outside
fire enclosures
fire enclosures
Fire enclosure not required,
refer to 4.7.2.
refer to 4.7.2.
N
4.7.3.4
Materials for components and other parts inside fire
enclosures
enclosures
Fire enclosure not required,
refer to 4.7.2.
refer to 4.7.2.
N
4.7.3.5
Materials for air filter assemblies
No air filters in the equipment.
N
4.7.3.6
Materials used in high-voltage components
No parts exceeding 4kV.
N
Measuring instrument
Inv. no.
Date
5
ELECTRICAL REQUIREMENTS AND SIMULATED ABNORMAL CONDITIONS
⎯
5.1
Touch current and protective conductor current
⎯
5.1.1
General
Class III equipment. Unit is
not intended for direct
connection to a mains supply.
No test considered
necessary.
not intended for direct
connection to a mains supply.
No test considered
necessary.
N
5.1.2
Configuration of equipment under test (EUT)
N
5.1.2.1
Single connection to an a.c. mains supply
N
5.1.2.2
Redundant multiple connections to an a.c. mains
supply
supply
N
5.1.2.3
Simultaneous multiple connections to an a.c. mains
supply
supply
N
5.1.3 Test
circuit
N
5.1.4
Application of measuring instrument
N
- Page 30 of 65 -
Report
No.
114383
IEC 60950-1:2005 / EN 60950-1:2006
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IECEN60950_1C
5.1.5 Test
procedure
N
5.1.6 Test
measurements
N
Supply
voltage (V) ................................................:
⎯
Measured touch current (mA) ..............................:
⎯
Max. allowed touch current (mA) .........................:
⎯
Measured protective conductor current (mA) .......:
⎯
Max. allowed protective conductor current (mA)...:
⎯
5.1.7
Equipment with touch current exceeding 3,5 mA
N
5.1.7.1 General .................................................................:
N
5.1.7.2
Simultaneous multiple connections to the supply
N
5.1.8
Touch currents to telecommunication networks and
cable distribution systems and from
telecommunication networks
cable distribution systems and from
telecommunication networks
Not connected to a
telecommunication network
nor a cable distribution
system.
telecommunication network
nor a cable distribution
system.
N
5.1.8.1
Limitation of the touch current to a
telecommunication network or to a cable distribution
system
telecommunication network or to a cable distribution
system
N
Supply
voltage (V) ................................................:
⎯
Measured touch current (mA) ..............................:
⎯
Max. allowed touch current (mA) .........................:
⎯
5.1.8.2
Summation of touch currents from telecommunication
networks
networks
N
a) EUT with earthed telecommunication ports .....:
N
b) EUT whose telecommunication ports have no
reference to protective earth
reference to protective earth
N
Measuring instrument
Inv. no.
Date
5.2 Electric
strength
⎯
5.2.1
General
Functional insulation, no test
required.
required.
N
5.2.2
Test procedure
N
- Page 31 of 65 -
Report
No.
114383
IEC 60950-1:2005 / EN 60950-1:2006
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IECEN60950_1C
Measuring instrument
Inv. no.
Date
5.3
Abnormal operating and fault conditions
⎯
5.3.1
Protection against overload and abnormal operation
(see appended table 5.3)
P
5.3.2
Motors
There is no motor in the
equipment.
equipment.
N
5.3.3
Transformers
There are no safety
transformers in the
equipment.
transformers in the
equipment.
N
5.3.4 Functional
insulation .............................................: Complies with c).
P
5.3.5
Electromechanical components
No electromechanical
components in secondary
circuits.
components in secondary
circuits.
N
5.3.6
Audio amplifiers in ITE .........................................:
See the enclosed fault
condition tests.
condition tests.
P
5.3.7
Simulation of faults
See the enclosed fault
condition tests.
condition tests.
P
5.3.8 Unattended
equipment
No
thermostats, temperauter
limiters or thermal cut-outs.
N
5.3.9
Compliance criteria for abnormal operating and fault
conditions
conditions
See below.
P
5.3.9.1
During the tests
No fire or molten metal
occurred and no deformation
of enclosure during the tests.
occurred and no deformation
of enclosure during the tests.
P
5.3.9.2
After the tests
No hazard. Class III
equipment.
equipment.
P
Measuring instrument
Inv. no.
Date
6
CONNECTION TO TELECOMMUNICATION NETWORKS
⎯
- Page 32 of 65 -
Report
No.
114383
IEC 60950-1:2005 / EN 60950-1:2006
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IECEN60950_1C
6.1
Protection of telecommunication network service persons, and users of other
equipment connected to the network, from hazards in the equipment
equipment connected to the network, from hazards in the equipment
⎯
6.1.1
Protection from hazardous voltages
⎯
6.1.2
Separation of the telecommunication network from earth
⎯
6.1.2.1
Requirements
No TNV circuit.
N
Supply
voltage (V) ................................................:
⎯
Current in the test circuit (mA) ...........................:
⎯
6.1.2.2 Exclusions ............................................................:
N
Measuring instrument
Inv. no.
Date
6.2
Protection of equipment users from overvoltages on telecommunication networks
⎯
6.2.1 Separation
requirements
N
6.2.2
Electric strength test procedure
N
6.2.2.1 Impulse
test
N
6.2.2.2 Steady-state
test
N
6.2.2.3 Compliance
criteria
N
Measuring instrument
Inv. no.
Date
6.3
Protection of the telecommunication wiring system from overheating
⎯
Max. output current (A) .........................................:
⎯
Current
limiting method ........................................:
⎯
Measuring instrument
Inv. no.
Date