JBL CS460 (serv.man3) EMC - CB Certificate ▷ View online
mikes-testingpartners gmbh
File
No.
F30272-02-00HM
, page
20 of 22
Ohmstrasse 2-4
x 94342 Strasskirchen
Tel.:+49(0)9424-94810
x Fax:+49(0)9424-9481240
Rev. No. 1.2
6 U S E D T E S T E Q U I P M E N T A N D A C C E S S O R I E S
All test instruments used, in addition to the test accessories, are calibrated and verified regularly.
Test ID
Model / Type
Kind of Equipment
Manufacturer
Equipment No.
I 2
AFG 100
Arbitrary Function Generat Grundig AG
02-02/05-05-002
NSG 435
ESD Generator
Schaffner Elektrotest GmbH
02-02/09-05-002
THL-313
Thermo-Hygro-Meter
PTL Dr. Grabenhorst GmbH
02-02/15-05-001
FLUKE 123
Scopemeter
Fluke Deutschland GmbH
02-03/13-05-002
I 3
AFG 100
Arbitrary Function Generat Grundig AG
02-02/05-05-002
SML 01
Signal Generator
Rohde & Schwarz München
02-02/05-05-013
NRVD
Dual Channel Power Meter Rohde & Schwarz München
02-02/07-05-004
NRV-Z1
Diode Power Sensor
Rohde & Schwarz München
02-02/07-05-017
NRV-Z1
Diode Power Sensor
Rohde & Schwarz München
02-02/07-05-018
LMV-1817
Noise Meter
Leader
02-02/07-05-028
500W1000A
RF Amplifier
Amplifier Research
02-02/17-05-010
CBL6140A
Bilog Antenna
Schaffner Elektrotest GmbH
02-02/24-05-018
KK-RG393/U-3
RF Cable 3m
Huber + Suhner
02-02/50-05-018
50 Ohm / 10 dB / 18 GHz
Attenuator
Huber + Suhner
02-02/50-05-037
DC6180A
Coupler
Amplifier Research
02-02/50-05-107
N-2000-N
RF Cable
mikes-testingpartners gmbh
02-02/50-05-108
RG 393/U 50 Ohm
RF Cable
mikes-testingpartners gmbh
02-02/50-06-024
I 4
AFG 100
Arbitrary Function Generat Grundig AG
02-02/05-05-002
NSG 2025
Burst Generator
Schaffner Elektrotest GmbH
02-02/09-05-003
FLUKE 123
Scopemeter
Fluke Deutschland GmbH
02-03/13-05-002
S 2
SML 01
Signal Generator
Rohde & Schwarz München
02-02/05-05-004
6000N
RF Amplifier
PMM
02-02/17-05-001
UPL
Audio Analyzer
Rohde & Schwarz München
02-02/19-05-001
RCo 8 Ohm
RC Network
Erika Fiedler Messtechnik
02-02/22-05-025
RCi 47 kOhm
RC Network
Erika Fiedler Messtechnik
02-02/22-05-029
MSF
Mains Filter
Erika Fiedler Messtechnik
02-02/22-05-067
PSU
RF Relaismatrix
Rohde & Schwarz München
02-02/50-05-002
JFW 50FHC-006-25
RF Attenuator 6 dB/25 W
jfw
02-02/50-05-020
ZFSC-2-2
Power Splitter
6011
Power Divider DC-118 GH Tactron Elektronik
02-02/50-05-080
S 3
SML 01
Signal Generator
Rohde & Schwarz München
02-02/05-05-004
URV 35
RF Voltmeter
Rohde & Schwarz München
02-02/07-05-009
URV 5 - Z 7
RF Probe
Rohde & Schwarz München
02-02/07-05-011
6000N
RF Amplifier
PMM
02-02/17-05-001
UPL
Audio Analyzer
Rohde & Schwarz München
02-02/19-05-001
Mains Stop Filter S3
Mains Stop Filter S3
Erika Fiedler Messtechnik
02-02/22-05-070
LBS
Band-Stop-Filter
Erika Fiedler Messtechnik
02-02/22-05-071
Open Strip Line
Open Strip Line
Natural Audio Lautsprecher
02-02/24-05-011
PSU
RF Relaismatrix
Rohde & Schwarz München
02-02/50-05-002
ZFSC-2-2
Power Splitter
6011
Power Divider DC-118 GH Tactron Elektronik
02-02/50-05-080
mikes-testingpartners gmbh
File
No.
F30272-02-00HM
, page
21 of 22
Ohmstrasse 2-4
x 94342 Strasskirchen
Tel.:+49(0)9424-94810
x Fax:+49(0)9424-9481240
Rev. No. 1.2
7 T e s t p r o t o c o l ( s )
7.1
Immunity requirements - S2 Test protocol(s)
Test point (injection into) : LFE
Mode of EUT : LFE
Criterion : Sound
Ref.-S/N : 57 dB
Monitoring : Speaker Woofer
Output : 54 mW/8 Ohm
Channel : left
Start Margin : 6 dB over limit
Test Engineer : Michael Hackl
Date : 25.08.2006
Place : Immunity Site 1
Test point (injection into) : LINE
Mode of EUT : LINE
Criterion : Sound
Ref.-S/N : 58 dB
Monitoring : Speaker Woofer
Output : 45 mW/8 Ohm
Channel : left
Start Margin : 6 dB over limit
Test Engineer : Michael Hackl
Date : 25.08.2006
Place : Immunity Site 1
mikes-testingpartners gmbh
File
No.
F30272-02-00HM
, page
22 of 22
Ohmstrasse 2-4
x 94342 Strasskirchen
Tel.:+49(0)9424-94810
x Fax:+49(0)9424-9481240
Rev. No. 1.2
Test point (injection into) : MAINS
Mode of EUT : LINE
Criterion : Sound
Ref.-S/N : 57 dB
Monitoring : Speaker Woofer
Output : 45 mW/8 Ohm
Channel : left
Start Margin : 6 dB over limit
Test Engineer : Michael Hackl
Date : 25.08.2006
Place : Immunity Site 1
Frequency Level
Limit Margin Frequency Level
Limit Margin
[MHz] [dB(µV)]
[dB(µV)] [dB]
[MHz] [dB(µV)]
[dB(µV)] [dB]
11.5 135 130 5 11.7 134 130 4
11.9 134 130 4 12.1 135 130 5
11.9 134 130 4 12.1 135 130 5
7.2
Immunity requirements - S3 Test protocol(s)
Mode of EUT : LINE
Criterion : Sound
Ref.-S/N : 62 dB
Monitoring : Speaker Woofer
Output : 51 mW/8 Ohm
Channel : left
Start Margin : 6 dB over limit
Test Engineer : Michael Hackl
Date : 25.08.2006
Place : Immunity Site 1
mikes-testingpartners gmbh
File
No.
F30272-02-00HM
, page
22 of 22
Ohmstrasse 2-4
x 94342 Strasskirchen
Tel.:+49(0)9424-94810
x Fax:+49(0)9424-9481240
Rev. No. 1.2
Test point (injection into) : MAINS
Mode of EUT : LINE
Criterion : Sound
Ref.-S/N : 57 dB
Monitoring : Speaker Woofer
Output : 45 mW/8 Ohm
Channel : left
Start Margin : 6 dB over limit
Test Engineer : Michael Hackl
Date : 25.08.2006
Place : Immunity Site 1
Frequency Level
Limit Margin Frequency Level
Limit Margin
[MHz] [dB(µV)]
[dB(µV)] [dB]
[MHz] [dB(µV)]
[dB(µV)] [dB]
11.5 135 130 5 11.7 134 130 4
11.9 134 130 4 12.1 135 130 5
11.9 134 130 4 12.1 135 130 5
7.2
Immunity requirements - S3 Test protocol(s)
Mode of EUT : LINE
Criterion : Sound
Ref.-S/N : 62 dB
Monitoring : Speaker Woofer
Output : 51 mW/8 Ohm
Channel : left
Start Margin : 6 dB over limit
Test Engineer : Michael Hackl
Date : 25.08.2006
Place : Immunity Site 1