JBL CS460 (serv.man3) EMC - CB Certificate ▷ View online
mikes-testingpartners gmbh
File
No.
F30272-02-00HM
, page
16 of 22
Ohmstrasse 2-4
x 94342 Strasskirchen
Tel.:+49(0)9424-94810
x Fax:+49(0)9424-9481240
Rev. No. 1.2
5.7.3 Test
specification
Contact discharge voltage:
2 kV
/
4 kV
Air discharge voltage:
2 kV
/
4 kV
/
8 kV
Discharge impedance:
330
Ω / 150 pF
Discharge factor:
≥ 1 sec.
Number of discharges:
≥ 10
Type of discharge:
Direct discharge:
- Contact discharge
- Air discharge
Indirect discharge:
- Contact discharge
Polarity:
- positive
- negative
Discharge location:
- all external locations accessible by hand
- see photo documentation of the test set-up
- horizontal plate (HCP)
- vertical coupling plate (VCP)
- see photo documentation of the test set-up
- horizontal plate (HCP)
- vertical coupling plate (VCP)
5.7.4 Test
result
The requirements are
FULFILLED.
Performance Criterion:
B
Remarks:
During electrostatic discharge the sine wave disappears and then reappears by itself.
mikes-testingpartners gmbh
File
No.
F30272-02-00HM
, page
17 of 22
Ohmstrasse 2-4
x 94342 Strasskirchen
Tel.:+49(0)9424-94810
x Fax:+49(0)9424-9481240
Rev. No. 1.2
5.8 Radiated,
radio-frequency, electromagnetic field
For test instruments and accessories used see section 6 Part I 3.
5.8.1 Description of the test location
Test location:
Test location:
Anechoic Chamber A2
5.8.2 Photo documentation of the test set-up
5.8.3 Test
specification
Frequency range:
900 MHz Pulse modulation
Field strength: 3
V/m
EuT - antenna distance: 3
m
Modulation:
PM / square wave: 217 Hz / duty cycle: 12.5 %
Antenna polarisation: -
vertical
5.8.4 Test
result
The requirements are
FULFILLED.
Performance Criterion:
A
Remarks:
During the test no deviation was detected to the selected operation mode(s).
mikes-testingpartners gmbh
File
No.
F30272-02-00HM
, page
18 of 22
Ohmstrasse 2-4
x 94342 Strasskirchen
Tel.:+49(0)9424-94810
x Fax:+49(0)9424-9481240
Rev. No. 1.2
5.9
Electrical fast transients / Burst
For test instruments and accessories used see section 6 Part I 4.
5.9.1 Description of the test location
Test location:
Test location:
Shielded Room S3
5.9.2 Photo documentation of the test set-up
5.9.3 Test
specification
Coupling network: 1
kV
Burst frequency: 5.0
kHz
Coupling duration:
≥ 60 sec.
Polarity:
- positive
- negative
mikes-testingpartners gmbh
File
No.
F30272-02-00HM
, page
19 of 22
Ohmstrasse 2-4
x 94342 Strasskirchen
Tel.:+49(0)9424-94810
x Fax:+49(0)9424-9481240
Rev. No. 1.2
5.9.4 Coupling
points
Cable description:
AC power line
Screening:
Status:
Signal transmission:
unscreened
active
analogue
active
analogue
Length: 0.5
m
5.9.5 Test
result
The requirements are
FULFILLED.
Performance Criterion:
B
Remarks:
During fast transients the sine wave disappears and then reappears by itself.