JBL CINEMA SOUND 5 EMC - CB Certificate ▷ View online

 
                                                                            Page 39 of 70                   Report No. JSH006110065-002 
 
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No:  IEC/EN 60065H 
 
     TRF originator Intertek ETL SEMKO SH 
 
 
Object/part 
No. 
Manufacturer/ 
trademark 
Type/model 
Technical data
Standard 
Mark(s) of 
conformity
(alternative) 
SUN HUNG (ZHUHAI) 
ELECTRONICS 
TECHNOLOGY CO 
LTD 
SHDS01 
FV-0, 130
°C 
IEC60695-11-10 UL: 
E228944  
and tested 
with 
appliance 
(alternative) 
E CITY P C B CO LTD  EC-2 
 
FV-0, 130
°C 
IEC60695-11-10 UL: 
E188100  
and tested 
with 
appliance 
(alternative) 
XING DA PRINTED 
CIRCUIT BOARD MFR 
CO LTD 
XD-102 
FV-0, 130
°C 
IEC60695-11-10 UL: 
E193079  
and tested 
with 
appliance 
(alternative) MILLION 
SOURCES 
CO LTD HK 
MS-1 
 
FV-0, 130
°C 
IEC60695-11-10 UL: 
E198407 
and tested 
with 
appliance 
(alternative) 
BRAIN POWER CO 
ML  
FV-0, 105
°C 
IEC60695-11-10 UL: 
E186014 
and tested 
with 
appliance 
(alternative) 
SHENZHEN TONGXIN 
CIRCUIT 
ELECTRONICS 
CO LTD 
TY-01 
FV0, 130℃ 
1.4mm min 
IEC 60707 
UL: 
E201362  
and tested 
with 
appliance 
(alternative) 
LUKS ELECTRICAL 
APPLIANCE MFY LTD 
LK-D-26-V0 
FV0, 130℃ 
1.4mm min 
IEC 60707 
UL: 
E78613   
and tested 
with 
appliance 
Insulated 
resistance 
KOA CORPORATION 
RCR60 
11MΩ,1W, 2pcs 
in series used 
 
IEC 60065 
VDE:12406
9 and 
tested with 
appliance
Plastic for 
vent hole  
Shanghai Pret 
Components Co., Ltd.
 
4330R 
FV-0 
IEC 60065 
UL: 
E301296
  
and tested 
with 
appliance 
 
                                                                            Page 40 of 70                   Report No. JSH006110065-002 
 
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No:  IEC/EN 60065H 
 
     TRF originator Intertek ETL SEMKO SH 
 
 
 
 
National differences for CHINA 
(According to CB bulletin No. 110A. These differences are taken from 
IEC60065:1998 and adopted to IEC 60065:2001.)
 
 
 
4.2.1 first sentence replaced by: 
The apparatus is connected to a supply voltage 
of 0.9 times or 1.1 times of any RATED SUPPLY 
VOLTAGE for which the apparatus is designed. 
 P 
 
5.1f
 Second paragraph replaced by: 
………When single rated voltage is given, it 
should be marked 220 V, For a rating range, it 
should cover 220 V; when multiple RATED 
VOLTAGES are given, one of them must be 
220V and also factory default setting should be 
220 V. 
 P 
 
5.4 replaced by
 
When information with regard to safety is 
required according to this standard, this 
information shall be given in an instruction for 
installation or use and supplied with the 
apparatus. This information shall be given in 
simplify Chinese where the apparatus is intended 
to be used. 
 P 
 
15.1.1 first sentence replaced by: 
Plugs and appliance couplers for the connection 
of the apparatus to the MAINS and socket-outlets 
and interconnection couplers for providing MAINS 
power to other apparatus shall comply with the 
Chinese National standards, Industrial standards 
or relevant IEC standards for plugs and socket-
outlets, appliance couplers or interconnection 
couplers. 
 P 
 
National differences for KOREA 
(According to CB bulletin No. 110A. These differences are taken from 
IEC60065:1998 and adopted to IEC 60065:2001.)
 
 
5.101 
Other marking ; Wording "____ “ or an 
information regulated in IEC Publication 417 
giving high voltage warning to layman shall 
be marked, if an apparatus contains a part more 
than 600volts. 
 N/A 
15.1.1 
Plugs for the connection of the apparatus to the 
supply mains and socket outlets for providing 
mains power to other apparatus shall 
comply with the Korean requirements (KSC8300 
and 8305). 
 P 
31 
Radio frequency interference 
The apparatus shall comply with the relevant 
CISPR requirements.(EMC = EMI + EMS) 
 P 
 
 
 
                                                                            Page 41 of 70                   Report No. JSH006110065-002 
 
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No:  IEC/EN 60065H 
 
     TRF originator Intertek ETL SEMKO SH 
 
 
 
National differences for SINGAPORE 
(According to CB bulletin No. 110A. These differences are taken from 
IEC60065:1992 and adopted to IEC 60065:2001.)
 
 
 
Throughout the standard
, whenever the words “white pine board” appear, insert 
the words “or plywood board” to it. 
 
SS 143 Amendment No.1 and No. 2 
 
4.1.3 
Delete “45 % to 75 %” and insert “65 _ 5 %”. 
75% maximum in IEC 
60065:2001 
7.1 
Resistance to heat without external forces 
Adopt the temperature specified for the tropical 
conditions. 
 P 
 9.3.4 
Delete the note “A Quality Assessment System 
for capacitors complying with Subclause 14.2 is 
under consideration in the IEC”. 
This is not in IEC 60065:2001. 
10.2 
Humidity treatment 
Adopt the testing conditions designed for tropical 
conditions. 
120h at a relative humidity of 
93%, ambient temperature 
40
o
16 
External flexible cords 
Delete “IEC Publication 227: Polyvinyl Cloride 
Insulated Cables of Rated Voltages up to and 
Including 450/750 V and IEC Publication 245: 
Rubber Insulated Cables of Rated Voltage up to 
and including 450/750V” and insert “Singapore 
Standard 236: Flexible Cords”, whenever they 
appear in this clause. 
Delete “CEE Publication 13, CEE Publication 2 
and IEC Publication 173: Colours of the Cores of 
Flexible Cables and Cords” whenever they 
appear in this clause. 
 P 
16.2 
Delete the notes in small print and insert “A 
nominal cross-sectional area of 0.75 mm
2
 will 
satisfy this requirement”. 
 P 
16.4b 
Delete “Subclause 3.1 of IEC Publication 227-2: 
Part 2: Test Methods” and insert “Subclause 9.1 
of SS 236”: 
9.1 Flexing Test (except for tinsel cords, twisted 
twin and single core cords). 
The test shall be carried out by mieans of the 
apparatus shown in Figure 5. This apparatus has 
a carrier C supporting two pulleys A and B 
arranged so that the cord is horizontal between 
the pulleys. The carrier moves backward and 
forward over a distance of 1 m at an 
approximately constant speed of 0.33 m/s. 
A sample of flexible cord fabout 5 m long shall be 
stretched over the pulleys as shown in the figure, 
each end being loaded with a weight. The weight 
and the diameter of the pulleys A and B shall be 
as given in Table 1. 
 P 
 
                                                                            Page 42 of 70                   Report No. JSH006110065-002 
 
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No:  IEC/EN 60065H 
 
     TRF originator Intertek ETL SEMKO SH 
 
 
Screene cords in accordance with Table 7 shall 
be tested before application of the screen and 
outer sheath. 
The pulleys shall have a semi-circular shaped 
groove for circular cords and a flat groove for 
parallel twin cords. The 
restraining clamps D shall be fixed so that the pull 
is always applied by the weight from which the 
carrier is mowing away. The carrier shall make 30 
000 backward and forward movements (60 000 
single strokes). Each conductor of the sample 
shall be loaded with the current specified in Table 
2. 
For twin cords and for light PVC-sheated 3-core 
cords, the voltage between the conductors shall 
be approximately 230 V a.c. For all other cords 
having three or more cores a three-phase a.c. 
voltage of about 400 V shall be applied to three 
conductors, any additional conductors being 
connected to the neutral. 
During the test no open-circuit in any core or 
short-circuit between cores shall occur. 
After the test, any sheath on cords having three 
or more cores shall be removed. The cord, or the 
laid up cores, shall then withstand the voltage 
test specified in Subclause 8.2. or 8.3 as 
appropriate, but with a test voltage not exceeding 
2000 V. 
TABLE 1, TABLE 2, FIGURES 4 and 5, see the 
CB bulletin. 
*In parenthesis: clauses according to IEC60065:1992. 
 
 
National differences MALAYSIA, according to CB bulletin No. 110A 
IEC 60065(2001)
 
+ Amendment 1 (2005).
 
 
 
Energy Commission circular no.1 year 2003 
(no.1/2003) 
States that a Certificate of Approval is required 
for manufacturing, selling, Advertising, displaying 
or importing into Malaysia, electrical/electronic 
products Listed in Annex A. 
 N/A 
 
The supply voltage in Malaysia is 240 Vac, at 
50Hz. 
 P 
 
Class 0 and 01 appliances are not allowed 
Class II 
N/A 
 
13A fused plug-tops shall comply to Malaysian 
standard (MS 589:Part1:1997), if applicable. 
Same as BS1363 type. 
 
2-pin plug tops shall comply to Malaysian 
standard (MS 1578:2003) if applicable 
 N/A 
 
 
 
Page of 72