JBL CINEMA SOUND 5 EMC - CB Certificate ▷ View online
Page 39 of 70 Report No. JSH006110065-002
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No: IEC/EN 60065H
TRF originator Intertek ETL SEMKO SH
Object/part
No.
Manufacturer/
trademark
Type/model
Technical data
Standard
Mark(s) of
conformity
(alternative)
SUN HUNG (ZHUHAI)
ELECTRONICS
TECHNOLOGY CO
LTD
SHDS01
FV-0, 130
°C
IEC60695-11-10 UL:
E228944
and tested
with
appliance
and tested
with
appliance
(alternative)
E CITY P C B CO LTD EC-2
FV-0, 130
°C
IEC60695-11-10 UL:
E188100
and tested
with
appliance
and tested
with
appliance
(alternative)
XING DA PRINTED
CIRCUIT BOARD MFR
CO LTD
XD-102
FV-0, 130
°C
IEC60695-11-10 UL:
E193079
and tested
with
appliance
and tested
with
appliance
(alternative) MILLION
SOURCES
CO LTD HK
MS-1
FV-0, 130
°C
IEC60695-11-10 UL:
E198407
and tested
with
appliance
and tested
with
appliance
(alternative)
BRAIN POWER CO
ML
FV-0, 105
°C
IEC60695-11-10 UL:
E186014
and tested
with
appliance
and tested
with
appliance
(alternative)
SHENZHEN TONGXIN
CIRCUIT
ELECTRONICS
CO LTD
CIRCUIT
ELECTRONICS
CO LTD
TY-01
FV0, 130℃
1.4mm min
1.4mm min
IEC 60707
UL:
E201362
and tested
with
appliance
E201362
and tested
with
appliance
(alternative)
LUKS ELECTRICAL
APPLIANCE MFY LTD
APPLIANCE MFY LTD
LK-D-26-V0
FV0, 130℃
1.4mm min
1.4mm min
IEC 60707
UL:
E78613
and tested
with
appliance
E78613
and tested
with
appliance
Insulated
resistance
KOA CORPORATION
RCR60
11MΩ,1W, 2pcs
in series used
IEC 60065
VDE:12406
9 and
tested with
appliance
Plastic for
vent hole
vent hole
Shanghai Pret
Components Co., Ltd.
4330R
FV-0
IEC 60065
UL:
E301296
and tested
with
appliance
with
appliance
Page 40 of 70 Report No. JSH006110065-002
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No: IEC/EN 60065H
TRF originator Intertek ETL SEMKO SH
National differences for CHINA
(According to CB bulletin No. 110A. These differences are taken from
IEC60065:1998 and adopted to IEC 60065:2001.)
(According to CB bulletin No. 110A. These differences are taken from
IEC60065:1998 and adopted to IEC 60065:2001.)
4.2.1 first sentence replaced by:
The apparatus is connected to a supply voltage
of 0.9 times or 1.1 times of any RATED SUPPLY
VOLTAGE for which the apparatus is designed.
The apparatus is connected to a supply voltage
of 0.9 times or 1.1 times of any RATED SUPPLY
VOLTAGE for which the apparatus is designed.
P
5.1f
)
Second paragraph replaced by:
………When single rated voltage is given, it
should be marked 220 V, For a rating range, it
should cover 220 V; when multiple RATED
VOLTAGES are given, one of them must be
220V and also factory default setting should be
220 V.
should be marked 220 V, For a rating range, it
should cover 220 V; when multiple RATED
VOLTAGES are given, one of them must be
220V and also factory default setting should be
220 V.
P
5.4 replaced by
:
When information with regard to safety is
required according to this standard, this
information shall be given in an instruction for
installation or use and supplied with the
apparatus. This information shall be given in
simplify Chinese where the apparatus is intended
to be used.
required according to this standard, this
information shall be given in an instruction for
installation or use and supplied with the
apparatus. This information shall be given in
simplify Chinese where the apparatus is intended
to be used.
P
15.1.1 first sentence replaced by:
Plugs and appliance couplers for the connection
of the apparatus to the MAINS and socket-outlets
and interconnection couplers for providing MAINS
power to other apparatus shall comply with the
Chinese National standards, Industrial standards
or relevant IEC standards for plugs and socket-
outlets, appliance couplers or interconnection
couplers.
Plugs and appliance couplers for the connection
of the apparatus to the MAINS and socket-outlets
and interconnection couplers for providing MAINS
power to other apparatus shall comply with the
Chinese National standards, Industrial standards
or relevant IEC standards for plugs and socket-
outlets, appliance couplers or interconnection
couplers.
P
National differences for KOREA
(According to CB bulletin No. 110A. These differences are taken from
IEC60065:1998 and adopted to IEC 60065:2001.)
(According to CB bulletin No. 110A. These differences are taken from
IEC60065:1998 and adopted to IEC 60065:2001.)
5.101
Other marking ; Wording "____ “ or an
information regulated in IEC Publication 417
giving high voltage warning to layman shall
be marked, if an apparatus contains a part more
than 600volts.
information regulated in IEC Publication 417
giving high voltage warning to layman shall
be marked, if an apparatus contains a part more
than 600volts.
N/A
15.1.1
Plugs for the connection of the apparatus to the
supply mains and socket outlets for providing
mains power to other apparatus shall
comply with the Korean requirements (KSC8300
and 8305).
supply mains and socket outlets for providing
mains power to other apparatus shall
comply with the Korean requirements (KSC8300
and 8305).
P
31
Radio frequency interference
The apparatus shall comply with the relevant
CISPR requirements.(EMC = EMI + EMS)
The apparatus shall comply with the relevant
CISPR requirements.(EMC = EMI + EMS)
P
Page 41 of 70 Report No. JSH006110065-002
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No: IEC/EN 60065H
TRF originator Intertek ETL SEMKO SH
National differences for SINGAPORE
(According to CB bulletin No. 110A. These differences are taken from
IEC60065:1992 and adopted to IEC 60065:2001.)
(According to CB bulletin No. 110A. These differences are taken from
IEC60065:1992 and adopted to IEC 60065:2001.)
Throughout the standard
, whenever the words “white pine board” appear, insert
the words “or plywood board” to it.
P
SS 143 Amendment No.1 and No. 2
4.1.3
Delete “45 % to 75 %” and insert “65 _ 5 %”.
75% maximum in IEC
60065:2001
60065:2001
P
7.1
Resistance to heat without external forces
Adopt the temperature specified for the tropical
conditions.
Adopt the temperature specified for the tropical
conditions.
P
9.3.4
Delete the note “A Quality Assessment System
for capacitors complying with Subclause 14.2 is
under consideration in the IEC”.
for capacitors complying with Subclause 14.2 is
under consideration in the IEC”.
This is not in IEC 60065:2001.
P
10.2
Humidity treatment
Adopt the testing conditions designed for tropical
conditions.
Adopt the testing conditions designed for tropical
conditions.
120h at a relative humidity of
93%, ambient temperature
40
93%, ambient temperature
40
o
C
P
16
External flexible cords
Delete “IEC Publication 227: Polyvinyl Cloride
Insulated Cables of Rated Voltages up to and
Including 450/750 V and IEC Publication 245:
Rubber Insulated Cables of Rated Voltage up to
and including 450/750V” and insert “Singapore
Standard 236: Flexible Cords”, whenever they
appear in this clause.
Delete “CEE Publication 13, CEE Publication 2
and IEC Publication 173: Colours of the Cores of
Flexible Cables and Cords” whenever they
appear in this clause.
Delete “IEC Publication 227: Polyvinyl Cloride
Insulated Cables of Rated Voltages up to and
Including 450/750 V and IEC Publication 245:
Rubber Insulated Cables of Rated Voltage up to
and including 450/750V” and insert “Singapore
Standard 236: Flexible Cords”, whenever they
appear in this clause.
Delete “CEE Publication 13, CEE Publication 2
and IEC Publication 173: Colours of the Cores of
Flexible Cables and Cords” whenever they
appear in this clause.
P
16.2
Delete the notes in small print and insert “A
nominal cross-sectional area of 0.75 mm
nominal cross-sectional area of 0.75 mm
2
will
satisfy this requirement”.
P
16.4b
Delete “Subclause 3.1 of IEC Publication 227-2:
Part 2: Test Methods” and insert “Subclause 9.1
of SS 236”:
9.1 Flexing Test (except for tinsel cords, twisted
twin and single core cords).
The test shall be carried out by mieans of the
apparatus shown in Figure 5. This apparatus has
a carrier C supporting two pulleys A and B
arranged so that the cord is horizontal between
the pulleys. The carrier moves backward and
forward over a distance of 1 m at an
approximately constant speed of 0.33 m/s.
A sample of flexible cord fabout 5 m long shall be
stretched over the pulleys as shown in the figure,
each end being loaded with a weight. The weight
and the diameter of the pulleys A and B shall be
as given in Table 1.
Part 2: Test Methods” and insert “Subclause 9.1
of SS 236”:
9.1 Flexing Test (except for tinsel cords, twisted
twin and single core cords).
The test shall be carried out by mieans of the
apparatus shown in Figure 5. This apparatus has
a carrier C supporting two pulleys A and B
arranged so that the cord is horizontal between
the pulleys. The carrier moves backward and
forward over a distance of 1 m at an
approximately constant speed of 0.33 m/s.
A sample of flexible cord fabout 5 m long shall be
stretched over the pulleys as shown in the figure,
each end being loaded with a weight. The weight
and the diameter of the pulleys A and B shall be
as given in Table 1.
P
Page 42 of 70 Report No. JSH006110065-002
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No: IEC/EN 60065H
TRF originator Intertek ETL SEMKO SH
Screene cords in accordance with Table 7 shall
be tested before application of the screen and
outer sheath.
The pulleys shall have a semi-circular shaped
groove for circular cords and a flat groove for
parallel twin cords. The
restraining clamps D shall be fixed so that the pull
is always applied by the weight from which the
carrier is mowing away. The carrier shall make 30
000 backward and forward movements (60 000
single strokes). Each conductor of the sample
shall be loaded with the current specified in Table
2.
For twin cords and for light PVC-sheated 3-core
cords, the voltage between the conductors shall
be approximately 230 V a.c. For all other cords
having three or more cores a three-phase a.c.
voltage of about 400 V shall be applied to three
conductors, any additional conductors being
connected to the neutral.
During the test no open-circuit in any core or
short-circuit between cores shall occur.
After the test, any sheath on cords having three
or more cores shall be removed. The cord, or the
laid up cores, shall then withstand the voltage
test specified in Subclause 8.2. or 8.3 as
appropriate, but with a test voltage not exceeding
2000 V.
TABLE 1, TABLE 2, FIGURES 4 and 5, see the
CB bulletin.
be tested before application of the screen and
outer sheath.
The pulleys shall have a semi-circular shaped
groove for circular cords and a flat groove for
parallel twin cords. The
restraining clamps D shall be fixed so that the pull
is always applied by the weight from which the
carrier is mowing away. The carrier shall make 30
000 backward and forward movements (60 000
single strokes). Each conductor of the sample
shall be loaded with the current specified in Table
2.
For twin cords and for light PVC-sheated 3-core
cords, the voltage between the conductors shall
be approximately 230 V a.c. For all other cords
having three or more cores a three-phase a.c.
voltage of about 400 V shall be applied to three
conductors, any additional conductors being
connected to the neutral.
During the test no open-circuit in any core or
short-circuit between cores shall occur.
After the test, any sheath on cords having three
or more cores shall be removed. The cord, or the
laid up cores, shall then withstand the voltage
test specified in Subclause 8.2. or 8.3 as
appropriate, but with a test voltage not exceeding
2000 V.
TABLE 1, TABLE 2, FIGURES 4 and 5, see the
CB bulletin.
*In parenthesis: clauses according to IEC60065:1992.
National differences MALAYSIA, according to CB bulletin No. 110A
IEC 60065(2001)
IEC 60065(2001)
+ Amendment 1 (2005).
Energy Commission circular no.1 year 2003
(no.1/2003)
States that a Certificate of Approval is required
for manufacturing, selling, Advertising, displaying
or importing into Malaysia, electrical/electronic
products Listed in Annex A.
(no.1/2003)
States that a Certificate of Approval is required
for manufacturing, selling, Advertising, displaying
or importing into Malaysia, electrical/electronic
products Listed in Annex A.
N/A
The supply voltage in Malaysia is 240 Vac, at
50Hz.
50Hz.
P
Class 0 and 01 appliances are not allowed
Class II
N/A
13A fused plug-tops shall comply to Malaysian
standard (MS 589:Part1:1997), if applicable.
standard (MS 589:Part1:1997), if applicable.
Same as BS1363 type.
P
2-pin plug tops shall comply to Malaysian
standard (MS 1578:2003) if applicable
standard (MS 1578:2003) if applicable
N/A