JBL CINEMA SOUND 5 EMC - CB Certificate ▷ View online
Page 3 of 70 Report No. JSH JSH006110065-002
TRF No: IEC/EN 60065H
TRF originator Intertek ETL SEMKO SH
Test case verdicts
Test case does not apply to the test object.................. : N/A
Test item does meet the requirement .......................... : P(ass)
Test item does not meet the requirement .................... : F(ail)
Testing
Date of receipt of test item ........................................... : November 3, 2006
Date(s) of performance of test...................................... : November 3, 2006 –November 20, 2006
General remarks
This report shall not be reproduced except in full without the written approval of the testing laboratory.
The test results presented in this report relate only to the item(s) tested.
Determination of the test result includes consideration of measurement uncertainty from the test equipment
and methods.
"(see appended table)" refers to a table appended to the report.
This report shall not be reproduced except in full without the written approval of the testing laboratory.
The test results presented in this report relate only to the item(s) tested.
Determination of the test result includes consideration of measurement uncertainty from the test equipment
and methods.
"(see appended table)" refers to a table appended to the report.
“(see remark #)” refers to a remark appended to the report.
“(see Annex #) refers to an annex appended to the report.
Throughout this report a point is used as the decimal separator.
Throughout this report all the models are tested as typical models.
General product information:
N/A
Page 4 of 70 Report No. JSH006110065-002
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No: IEC/EN 60065H
TRF originator Intertek ETL SEMKO SH
3 GENERAL
REQUIREMENTS
Safety class of the apparatus ................................. : Class II
4
GENERAL CONDITIONS OF TESTS
4.1.4 Ventilation
instructions
require the use of the test
box
Yes
P
5 MARKING
Comprehensible and easily discernible
Printed on the rear enclosure
P
Permanent durability against water and petroleum
spirit
spirit
P
5.1 Identification,
maker, model ................................... : (see page 2)
P
Class II symbol if applicable
P
Rated supply voltage and symbol .......................... : 100-240 V
P
Frequency if safety dependant
50/60 Hz
P
Rated current or power consumption .................... : 500 W
P
5.2 Earth
terminal
N/A
Hazardous live terminals
N/A
Supply output terminals (other than mains)
N/A
5.3
Use of triangle with exclamation mark
On PCB
P
5.4
Instructions for use
P
5.4.1
Mains powered equipment not exposed to dripping
or splashing. Warning concerning objects filled
with liquid, etc.
or splashing. Warning concerning objects filled
with liquid, etc.
P
Hazardous live terminals, instructions for wiring
No such terminals
N/A
Instructions for replacing lithium battery
No lithium battery
N/A
Instructions for modem if fitted
No modem fitted
N/A
Class I earth connection warning
N/A
Instructions for multimedia system connection
P
Special stability warning for fixed installation
N/A
5.4.2
Disconnect device: plug/coupler or all-pole mains
switch location, accessibility and markings
switch location, accessibility and markings
Main plug or coupler is used
P
Instructions for permanently connected equipment
N/A
Page 5 of 70 Report No. JSH006110065-002
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No: IEC/EN 60065H
TRF originator Intertek ETL SEMKO SH
6 HAZARDOUS
RADIATION
6.1
Ionizing radiation < 36 pA/kg (0,5 mR/h)
No ionizing radiation
N/A
6.1
EN 60065
N/A
6.2
Laser radiation, emission limits to IEC 60825-1 .... : Class I M
P
Emission limits under fault conditions .................... : Laser Optical Pickup:Class 1M
P
7
HEATING UNDER NORMAL OPERATING CONDITIONS
7.1
Temperature rises not exceeding specified values,
no operation of fuse links
no operation of fuse links
(see appended table)
P
7.1.1
Temperature rise of accessible parts
(see appended table)
P
7.1.2
Temperature rise of parts providing electrical
insulation
insulation
(see appended table)
P
7.1.3
Temperature rise of parts acting as a support or as
a mechanical barrier
a mechanical barrier
(see appended table)
P
7.1.4
Temperature rise of windings
(see appended table)
P
7.1.5
Parts not subject to a limit under 7.1.1 to 7.1.4
(see appended table)
P
7.2
Softening temperature of insulating material
supporting parts conductively connected to the
mains carrying a current > 0,2 A at least 150
supporting parts conductively connected to the
mains carrying a current > 0,2 A at least 150
o
C
No such supporting parts
N/A
8
CONSTRUCTIONAL REQUIREMENTS WITH REGARD TO THE PROTECTION
AGAINST ELECTRIC SHOCK
AGAINST ELECTRIC SHOCK
8.1
Conductive parts covered by lacquer, paper,
untreated textile oxide films and beads etc.
considered to be bare
untreated textile oxide films and beads etc.
considered to be bare
PCB, windings
P
8.2
No shock hazard when changing voltage setting
device, fuse-links or handling drawers etc.
device, fuse-links or handling drawers etc.
Tools are required
P
8.3
Insulation of hazardous live parts not provided by
hygroscopic material
hygroscopic material
No hygroscopic material used
P
8.4
No risk of electric shock following the removal of a
cover which can be removed by hand
cover which can be removed by hand
Enclosure can not removed by
hand
hand
P
8.5
Class I equipment
Class II
N/A
Basic insulation between hazardous live parts and
earthed accessible parts
earthed accessible parts
N/A
Page 6 of 70 Report No. JSH006110065-002
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No: IEC/EN 60065H
TRF originator Intertek ETL SEMKO SH
Resistors bridging basic insulation complying with
14.2.1 a)
14.2.1 a)
N/A
8.6
Class II equipment and Class II constructions
within Class I equipment
within Class I equipment
P
Reinforced or double insulation between
hazardous live parts and accessible parts
hazardous live parts and accessible parts
P
Components bridging reinforced or double
insulation complying with 14.1 a) or 14.3
insulation complying with 14.1 a) or 14.3
T501, T502, R575
P
Basic and supplementary insulation each being
bridged by a capacitor complying with 14.2.1 a)
bridged by a capacitor complying with 14.2.1 a)
N/A
Reinforced or double insulation being bridged with
2 capacitors in series complying with 14.2.1 a)
2 capacitors in series complying with 14.2.1 a)
N/A
Reinforced or double insulation being bridged with
a single capacitor complying with 14.2.1 b)
a single capacitor complying with 14.2.1 b)
CY1, CY2, CY501, CY502
P
Basic insulation bridged by components complying
with 14.3.4.3
with 14.3.4.3
N/A
8.7
Basic insulation between parts at 35 V to 71 V
(peak) a.c. or 60 V to 120 V d.c. and accessible
parts
(peak) a.c. or 60 V to 120 V d.c. and accessible
parts
No such voltage
N/A
Reinforced or double insulation between circuits
operating at voltages between 35 V and 71 V
(peak) a.c. or between 60 V and 120 V d.c. and
hazardous live parts at higher voltage
operating at voltages between 35 V and 71 V
(peak) a.c. or between 60 V and 120 V d.c. and
hazardous live parts at higher voltage
N/A
Separation by Class II isolating transformer
N/A
Separation by Class I transformer
N/A
Separation by earthed conductive part
N/A
8.8
Basic or supplementary insulation > 0,4 mm (mm) :
N/A
Reinforced insulation > 0,4 mm (mm) .................... : Separation sheet between
internal enclosure and power
board: 0.6mm
board: 0.6mm
T501 bobbin: 0.85mm
T502 bobbin: 0.85mm
Optocoupler U502, U504,
U505: 0.50mm
U505: 0.50mm
P
Thin sheet insulation
Inside T501, T502
P
Basic or supplementary insulation, at least two
layers, each meeting 10.3
layers, each meeting 10.3
Withstand 2120Vp test.
P
Basic or supplementary insulation, three layers any
two of which meet 10.3
two of which meet 10.3
N/A
Click on the first or last page to see other CINEMA SOUND 5 service manuals if exist.