Page 11 of 70 Report No. JSH006110065-002
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No: IEC/EN 60065H
TRF originator Intertek ETL SEMKO SH
13.8
Parts filled with insulating compound, meeting the
requirements of 8.8
requirements of 8.8
N/A
14 COMPONENTS
14.1 Resistors
a) Resistors between hazardous live parts and
accessible metal parts
accessible metal parts
R575 P
b) Resistors, other than between hazardous live
parts and accessible parts
parts and accessible parts
N/A
Resistors separately approved .............................. : By VDE
P
14.2
Capacitors and RC units
P
Capacitors separately approved
Yes
P
14.2.1
Y capacitors tested to IEC 60384-14, 2
nd
edition .. : Y1: CY1, CY2, CY501, CY502
P
14.2.2
X capacitors tested to IEC 60384-14, 2
nd
edition .. : X2: C501, C502, C503
P
14.2.3 Capacitors
operating
at mains frequency but not
connected to the mains: tests for X2 ..................... :
No such capacitor
N/A
14.2.5
Capacitors with volume exceeding 1750 mm³,
where short-circuit current exceeds 0,2 A:
compliance with IEC60384-1, 4.38 category B or
better ....................................................................... :
where short-circuit current exceeds 0,2 A:
compliance with IEC60384-1, 4.38 category B or
better ....................................................................... :
No such capacitor
N/A
Capacitors with volume exceeding 1750 mm³,
mounted closer to a potential ignition source than
table 5 permits: compliance with IEC 60 384-1,
4.38 category B or better ........................................ :
mounted closer to a potential ignition source than
table 5 permits: compliance with IEC 60 384-1,
4.38 category B or better ........................................ :
N/A
Shielded by a barrier to V-0 or metal ..................... :
N/A
14.3
Inductors and windings
P
Comply with IEC 61558-1, IEC 61558-2
(as relevant) and clause 20.1.4
(as relevant) and clause 20.1.4
N/A
14.3.1
Transformers and inductors marked with
manufacturer's name and type .............................. :
manufacturer's name and type .............................. :
Switching mode transformer
T501: BCK-EC4201
T502: BCK-ER2855
Filter L512, L513:
LCL-ET2812
P
Transformers and inductors separately approved . :
N/A
14.3.2 General
P
14.3.3 Constructional
requirements
P
Page 12 of 70 Report No. JSH006110065-002
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No: IEC/EN 60065H
TRF originator Intertek ETL SEMKO SH
14.3.3.1
Clearances and creepage distances comply with
clause 13
clause 13
(see appended table)
P
14.3.3.2
Transformers meet the constructional
requirements
requirements
P
14.3.4.1
Class II transformers have adequate separation
between hazardous live parts and accessible parts
(double or reinforced insulation)
between hazardous live parts and accessible parts
(double or reinforced insulation)
T501 basic insulation
minimum 5.3 mm between
T501 core and primary,
Supplementary insulation
minimum 2.9mm between
T501 core and secondary.
minimum 5.3 mm between
T501 core and primary,
Supplementary insulation
minimum 2.9mm between
T501 core and secondary.
T502 basic insulation
minimum 4.2 mm between
T502 core and primary,
Supplementary insulation
minimum 4.2mm between
T502 core and secondary.
minimum 4.2 mm between
T502 core and primary,
Supplementary insulation
minimum 4.2mm between
T502 core and secondary.
P
Coil formers and partition walls > 0,4 mm
T501 bobbin: 0.85mm
T502 bobbin: 0.85mm
P
14.3.4.2
Class I transformers, with basic insulation and
protective screening only if all 7 conditions of
14.3.4.2 are met
protective screening only if all 7 conditions of
14.3.4.2 are met
N/A
14.3.4.3
Separating transformers with at least basic
insulation
insulation
N/A
14.3.5.1
Class II transformers have adequate insulation
between hazardous live parts and accessible parts
(double or reinforced insulation)
between hazardous live parts and accessible parts
(double or reinforced insulation)
T501 basic insulation
minimum 5.3 mm between
T501 core and primary,
Supplementary insulation
minimum 2.9mm between
T501 core and secondary.
minimum 5.3 mm between
T501 core and primary,
Supplementary insulation
minimum 2.9mm between
T501 core and secondary.
T502 basic insulation
minimum 4.2 mm between
T502 core and primary,
Supplementary insulation
minimum 4.2mm between
T502 core and secondary.
minimum 4.2 mm between
T502 core and primary,
Supplementary insulation
minimum 4.2mm between
T502 core and secondary.
P
Coil formers and partition walls > 0,4 mm
T501 bobbin: 0.85 mm
T502 bobbin: 0.85 mm
P
14.3.5.2
Class I transformers have adequate insulation
between hazardous live parts and accessible
conductive parts or those conductive parts or
protective screens connected to a protective earth
terminal
between hazardous live parts and accessible
conductive parts or those conductive parts or
protective screens connected to a protective earth
terminal
N/A
Page 13 of 70 Report No. JSH006110065-002
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No: IEC/EN 60065H
TRF originator Intertek ETL SEMKO SH
Winding wires connected to protective earth have
adequate current-carrying capacity
adequate current-carrying capacity
N/A
14.4
High voltage components
No such component
N/A
High-voltage components and assemblies:
U > 4 kV (peak) separately approved
U > 4 kV (peak) separately approved
N/A
Component meets category V-1 of IEC 60707
N/A
14.4.1
High voltage transformers and multipliers tested as
part of the submission
part of the submission
N/A
14.4.2
High voltage assemblies and other parts tested as
part of the submission
part of the submission
N/A
14.5 Protective
devices
P
Protective devices used within their ratings
P
External clearances and creepage distances meet
requirement of clause 13 for the voltage across the
device when opened
requirement of clause 13 for the voltage across the
device when opened
Fuse F501: 3.7mm
P
14.5.1.1
a) Thermal cut-outs separately approved
No such components
N/A
b) Thermal cut-outs tested as part of the
submission
submission
N/A
14.5.1.2
a) Thermal links separately approved
No such components
N/A
b) Thermal links tested as part of the submission
N/A
14.5.1.3
Thermal devices re-settable by soldering
N/A
14.5.2.1
Fuse-links in the mains circuit according to IEC
60127
60127
F501 approved.
P
14.5.2.2
Correct marking of fuse-links adjacent to holder ... : F501: T5A L 250V
P
14.5.2.3
Not possible to connect fuses in parallel ............... : Only one holder
P
14.5.2.4
Not possible to touch hazardous live parts when
replacing fuse-links without the use of a tool ......... :
replacing fuse-links without the use of a tool ......... :
Tools required
N/A
14.5.3
PTC-S thermistors comply with IEC 60730-1
No such component
N/A
PTC-S devices (15 W) category V-1 or better
N/A
14.5.4 Circuit
protectors
have adequate breaking capacity
and their position is correctly marked
N/A
14.6 Switches
No
switch
N/A
Page 14 of 70 Report No. JSH006110065-002
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No: IEC/EN 60065H
TRF originator Intertek ETL SEMKO SH
14.6.1 a)
Separate testing to IEC 61058 including:
10 000 operations
Normal pollution suitability
Resistance to heat and fire level 3
and
V-0 compliance with annex G, G.1.1
N/A
14.6.1 b)
Tested in the apparatus:
N/A
Switch controlling > 0.2A with open contact
voltage > 35 V (peak)/24 V dc complying with
14.6.3, 14.6.4 and V-0 in annex G, G.1.1
voltage > 35 V (peak)/24 V dc complying with
14.6.3, 14.6.4 and V-0 in annex G, G.1.1
N/A
Switch controlling > 0.2A with open contact
voltage < 35 V (peak)/24 V dc complying with
14.6.3 and V-0 in annex G, G.1.1
voltage < 35 V (peak)/24 V dc complying with
14.6.3 and V-0 in annex G, G.1.1
N/A
Switch controlling < 0.2A with open contact
voltage > 35 V (peak)/24 V dc complying with
14.6.4 and V-0 in annex G, G.1.1
voltage > 35 V (peak)/24 V dc complying with
14.6.4 and V-0 in annex G, G.1.1
N/A
14.6.2
Switch tested to 14.6.1 b) constructed to IEC
61058-1 subclause 13.1 and has making/breaking
action independent of speed of actuation
61058-1 subclause 13.1 and has making/breaking
action independent of speed of actuation
N/A
14.6.3
Switch tested to 14.6.1 b) compliant with IEC
61058-1 subclause 16.2.2 d) and m) not attaining
excessive temperatures in use
61058-1 subclause 16.2.2 d) and m) not attaining
excessive temperatures in use
N/A
14.6.4
Switch tested to 14.6.1 b) has adequate dielectric
strength
strength
N/A
14.6.5
Mains switch controlling mains socket outlets
additional tests to IEC 60058-1
additional tests to IEC 60058-1
N/A
Socket outlet current marking correct
N/A
14.7
Safety interlocks
No such device
N/A
Safety interlocks to 2.8 of IEC 60950
N/A
14.8
Voltage setting devices
No such device
N/A
Voltage setting device not likely to be changed
accidentally
accidentally
N/A
14.9
Motors
Only low voltage DC servo
motor in DVD loader
motor in DVD loader
N/A
14.9.1
Endurance test on motors
N/A
Motor start test
N/A
Dielectric strength test
N/A