                                                                            Page 11 of 70                   Report No. JSH006110065-002 
 
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No:  IEC/EN 60065H 
 
       TRF originator Intertek ETL SEMKO SH 
 
 
13.8 
Parts filled with insulating compound, meeting the 
requirements of 8.8 
         
 N/A 
 
 
14 COMPONENTS 
 
14.1 Resistors 
 
 
a) Resistors between hazardous live parts and 
accessible metal parts 
R575 P 
 
b) Resistors, other than between hazardous live 
parts and accessible parts 
 N/A 
 
Resistors separately approved  .............................. : By VDE 
14.2 
Capacitors and RC units 
         
 P 
 
Capacitors separately approved 
Yes 
14.2.1 
Y capacitors tested to IEC 60384-14, 2
nd
 edition  .. : Y1: CY1, CY2, CY501, CY502 
14.2.2 
X capacitors tested to IEC 60384-14, 2
nd
 edition  .. : X2: C501, C502, C503 
14.2.3 Capacitors 
operating 
at mains frequency but not 
connected to the mains: tests for X2  ..................... :
No such capacitor 
N/A 
14.2.5 
Capacitors with volume exceeding 1750 mm³, 
where short-circuit current exceeds 0,2 A: 
compliance with IEC60384-1, 4.38 category B or 
better ....................................................................... :
No such capacitor 
N/A 
 
Capacitors with volume exceeding 1750 mm³, 
mounted closer to a potential ignition source than 
table 5 permits: compliance with IEC 60 384-1, 
4.38 category B or better ........................................ :
 
N/A 
 
Shielded by a barrier to V-0 or metal ..................... :  
N/A 
14.3 
Inductors and windings 
 
 
Comply with IEC 61558-1, IEC 61558-2 
(as relevant) and clause 20.1.4 
 N/A 
14.3.1 
Transformers and inductors marked with 
manufacturer's name and type .............................. :
Switching mode transformer  
T501: BCK-EC4201 
T502: BCK-ER2855 
Filter L512, L513: 
LCL-ET2812 
 
Transformers and inductors separately approved . :  
N/A 
14.3.2 General 
 
14.3.3 Constructional 
requirements 
 
 
                                                                            Page 12 of 70                   Report No. JSH006110065-002 
 
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No:  IEC/EN 60065H 
 
       TRF originator Intertek ETL SEMKO SH 
 
 
14.3.3.1 
Clearances and creepage distances comply with 
clause 13 
(see appended table) 
14.3.3.2 
Transformers meet the constructional 
requirements 
 P 
14.3.4.1 
Class II transformers have adequate separation 
between hazardous live parts and accessible parts 
(double or reinforced insulation) 
T501 basic insulation 
minimum 5.3 mm between 
T501 core and primary, 
Supplementary insulation 
minimum 2.9mm between 
T501 core and secondary. 
T502 basic insulation 
minimum 4.2 mm between 
T502 core and primary, 
Supplementary insulation 
minimum 4.2mm between 
T502 core and secondary. 
 
Coil formers and partition walls > 0,4 mm 
T501 bobbin: 0.85mm 
T502 bobbin: 0.85mm 
14.3.4.2 
Class I transformers, with basic insulation and 
protective screening only if all 7 conditions of 
14.3.4.2 are met 
 N/A 
14.3.4.3 
Separating transformers with at least basic 
insulation 
         
 N/A 
14.3.5.1 
Class II transformers have adequate insulation 
between hazardous live parts and accessible parts 
(double or reinforced insulation) 
T501 basic insulation 
minimum 5.3 mm between 
T501 core and primary, 
Supplementary insulation 
minimum 2.9mm between 
T501 core and secondary. 
T502 basic insulation 
minimum 4.2 mm between 
T502 core and primary, 
Supplementary insulation 
minimum 4.2mm between 
T502 core and secondary. 
 
Coil formers and partition walls > 0,4 mm 
T501 bobbin: 0.85 mm 
T502 bobbin: 0.85 mm 
14.3.5.2 
Class I transformers have adequate insulation 
between hazardous live parts and accessible 
conductive parts or those conductive parts or 
protective screens connected to a protective earth 
terminal 
 N/A 
 
                                                                            Page 13 of 70                   Report No. JSH006110065-002 
 
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No:  IEC/EN 60065H 
 
       TRF originator Intertek ETL SEMKO SH 
 
 
 
Winding wires connected to protective earth have 
adequate current-carrying capacity 
 N/A 
14.4 
High voltage components 
No such component 
N/A 
 
High-voltage components and assemblies: 
U > 4 kV (peak) separately approved 
 N/A 
 
Component meets category V-1 of IEC 60707 
 
N/A 
14.4.1 
High voltage transformers and multipliers tested as 
part of the submission 
 N/A 
14.4.2 
High voltage assemblies and other parts tested as 
part of the submission 
 N/A 
14.5 Protective 
devices 
 
 
Protective devices used within their ratings 
 
 
External clearances and creepage distances meet 
requirement of clause 13 for the voltage across the 
device when opened 
Fuse F501: 3.7mm 
14.5.1.1 
a) Thermal cut-outs separately approved 
No such components 
N/A 
 
b) Thermal cut-outs tested as part of the 
submission 
 N/A 
14.5.1.2 
a) Thermal links separately approved 
No such components 
N/A 
 
b) Thermal links tested as part of the submission 
 
N/A 
14.5.1.3 
Thermal devices re-settable by soldering 
 
N/A 
14.5.2.1 
Fuse-links in the mains circuit according to IEC 
60127 
F501 approved. 
14.5.2.2 
Correct marking of fuse-links adjacent to holder ... : F501: T5A L 250V 
14.5.2.3 
Not possible to connect fuses in parallel  ............... : Only one holder 
14.5.2.4 
Not possible to touch hazardous live parts when 
replacing fuse-links without the use of a tool ......... :
Tools required 
N/A 
14.5.3 
PTC-S thermistors comply with IEC 60730-1 
No such component 
N/A 
 
PTC-S devices (15 W) category V-1 or better 
  
N/A 
14.5.4 Circuit 
protectors 
have adequate breaking capacity 
and their position is correctly marked 
         
 N/A 
14.6 Switches 
No 
switch 
N/A 
 
                                                                            Page 14 of 70                   Report No. JSH006110065-002 
 
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No:  IEC/EN 60065H 
 
       TRF originator Intertek ETL SEMKO SH 
 
 
14.6.1 a) 
Separate testing to IEC 61058 including: 
10 000 operations 
Normal pollution suitability 
Resistance to heat and fire level 3 
and 
V-0 compliance with annex G, G.1.1 
         
 N/A 
14.6.1 b) 
Tested in the apparatus: 
 
N/A 
 
Switch controlling > 0.2A with open contact  
voltage > 35 V (peak)/24 V dc complying with 
14.6.3, 14.6.4 and V-0 in annex G, G.1.1 
 N/A 
 
Switch controlling > 0.2A with open contact  
voltage < 35 V (peak)/24 V dc complying with 
14.6.3 and V-0 in annex G, G.1.1 
 N/A 
 
Switch controlling < 0.2A with open contact  
voltage > 35 V (peak)/24 V dc complying with  
14.6.4 and V-0 in annex G, G.1.1 
         
 N/A 
14.6.2 
Switch tested to 14.6.1 b) constructed to IEC 
61058-1 subclause 13.1 and has making/breaking  
action independent of speed of actuation 
         
 N/A 
14.6.3 
Switch tested to 14.6.1 b) compliant with IEC 
61058-1 subclause 16.2.2 d) and  m) not attaining 
excessive temperatures in use 
         
 N/A 
14.6.4 
Switch tested to 14.6.1 b) has adequate dielectric 
strength 
         
 N/A 
14.6.5 
Mains switch controlling mains socket outlets 
additional tests to IEC 60058-1 
         
 N/A 
 
Socket outlet current marking correct 
         
 N/A 
14.7 
Safety interlocks 
No such device 
N/A 
 
Safety interlocks to 2.8 of IEC 60950 
 
N/A 
14.8 
Voltage setting devices 
No such device 
N/A 
 
Voltage setting device not likely to be changed 
accidentally 
         
 N/A 
14.9 
Motors 
Only low voltage DC servo 
motor in DVD loader 
N/A 
14.9.1 
Endurance test on motors 
         
 N/A 
 
Motor start test 
         
 N/A 
 
Dielectric strength test 
         
 N/A 
Page of 72