JBL AUTHENTICS L8 (serv.man4) EMC - CB Certificate ▷ View online
Report No.: EM201300471-1 Application No.:
ZJ00032008 Page 5 of 57
2. GENERAL DESCRIPTION OF EUT
2.1 APPLICANT
Name: Harman
International
Industries, Incorporated
Address:
2.2 MANUFACTURER
Name: Harman
International
Industries, Incorporated
Address:
2.3 BASIC DESCRIPTION OF EQUIPMENT UNDER TEST
Equipment:
Active speaker system with wireless streaming
Model No.:
AUTHENTICS L16
Adding model:
AUTHENTICS L8
Trade Name:
JBL
Power supply
AC 100-240V,50/60Hz
Frequency Range:
2402MHz~2480MHz
Type of Modulation
GFSK, 8DPSK, Pi/4 QPSK
Channels:
Channels with 1MHz step
Antenna Type
PCB antenna
Antenna gain
3.08dBi
Report No.: EM201300471-1 Application No.:
ZJ00032008 Page 6 of 57
3. LABORATORY AND ACCREDITATIONS
3.1 LABORATORY
The tests and measurements refer to this report were performed by EMC Laboratory of Guangzhou GRG
Metrology and Test CO., LTD.
Add. : 163 Pingyun Rd, West of Huangpu Ave, Guangzhou, 510656, P. R. China
Telephone: +86-20-38699959, 38699960, 38699961
Fax
: +86-20-38695185
3.2 ACCREDITATIONS
Our laboratories are accredited and approved by the following approval agencies according
to ISO/IEC 17025.
to ISO/IEC 17025.
USA
FCC Listed Lab (No. 688188)
China
CNAS (No.L0446)
China
DILAC (No.DL175)
Canada
Registration No.:8355A-1
3.3 MEASUREMENT UNCERTAINTY
Where relevant, the following measurement uncertainty levels have been estimated for tests
performed on the EUT as specified in CISPR 16-4-2:
Measurement
Frequency
Uncertainty
Radiated
Emission
Horizontal
30MHz~1000MHz 4.2dB
1GHz~12.75GHz 4.2dB
Vertical
30MHz~1000MHz
4.4dB
1GHz~12.75GHz 4.4dB
This uncertainty represents an expanded uncertainty expressed at approximately the 95% confidence
level using a coverage factor of k=2.
level using a coverage factor of k=2.
Report No.: EM201300471-1 Application No.:
ZJ00032008 Page 7 of 57
3.4 LIST OF USED TEST EQUIPMENT AT GRGT
Name of Equipment
Manufacturer
Model
Serial Number Calibration Due
Maximum transmit power & Frequency Range
Receiver R&S
ESU40
100106
2014-01-24
Temperature& humidity
chamber
chamber
CEPREI CEEC-MSJ-60BE
11015
2014-05-21
AC power supply
WEST
WE-1120
681598
2014-07-01
AC power supply
LONGWEI
TPR-6420D
201109090
2014-09-20
Shielding room
ETS
RFD_100
3728
2014-03-25
Dwell Time & Hopping channel separation & Hopping sequence
Receiver R&S
ESU40
100106
2014-01-24
Shielding room
ETS
RFD_100
3728
2014-03-25
Spurious Emission from Tx/ Rx
Receiver R&S
ESU40
100106
2014-01-24
Loop antenna
R&S
HFH2-Z2
881058/58
2014-05-26
Biconical Log-periodic
Antenna
Antenna
ETS.LINDGREN 3142C
00075971
2014-05-26
Signal Generator
R&S
SML03
103002
2014-11-13
Biconical antenna
ELECTRO-METRICS BIA-30S
166
2014-05-26
log-periodical antenna
ELECTRO-METRICS LPA-30
383
2014-05-26
Horn antenna
ETS.LINDGREN
3117
00075824
2014-08-19
Horn antenna
SCHWARZBECK
BBHA9120D
D752
2014-10-14
Per-Amplifier
(0.1-26.5GHz)
(0.1-26.5GHz)
Compliance Directions
systems Inc.
systems Inc.
PAP-0126 25002
2014-01-05
Semi-anechoic chamber
ETS
966(RFD-F/A-100)
3730
2014-03-25
Report No.: EM201300471-1 Application No.:
ZJ00032008 Page 8 of 57
4.
RADIO TECHNICAL REQUIREMENTS SPECIFICATION IN EN
300 328
4.1 MAXIMUM TRANSMIT POWER
4.1.1 LIMITS
Frequency
EN300 328 clause 4.3.1
2400MHz~2483.5 MHz
20 dBm (i.e. 100mW)
4.1.2 TEST PROCEDURE
Test requirement:
EN 300 328 clause 4.3.1
Test Method:
EN 300 328 clause 5.7.2.2
EUT Operation:
Fixed Frequency
Status:
Keep EUT on transmitting mode by the software provided by
manufacturer.
manufacturer.
Test channel:
Lowest channel: (2402MHz)
Middle channel: (2441MHz),
Highest channel: (2480MHz)
Middle channel: (2441MHz),
Highest channel: (2480MHz)
Test condition:
Normal and extreme test conditions.
Equipment Used:
Refer to section 3.4
Test Procedure:
As annex C1 of standard EN 300328
Remark: Pre-test the 3 modulation to find GFSK and 8DPSK is worse case, so only record GFSK
and 8DPSK test data.
4.1.3 TEST SETUP
Antenna
EUT
Attenuator
Receiver