Harman Kardon SUB-TS 8 EMC - CB Certificate ▷ View online

 
 
page 5 of 31 
Ref.No.:413858  
IEC 60065 
Clause 
Requirement - Test 
Result - Remark 
Verdict 
 
 
TRF No.: I60065__C 
 
HEATING UNDER NORMAL OPERATING CONDITIONS (See appended table) 
 
7.1 
Temperature rises not exceeding specified values, 
no operation of fuse links 
 P 
7.1.1 
Temperature rise of accessible parts 
 
7.1.2 
Temperature rise of parts providing electrical 
insulation 
 P 
7.1.3 
Temperature rise of parts acting as a support or as 
a mechanical barrier 
 P 
7.1.4 
Temperature rise of windings 
 
7.1.5 
Parts not subject to a limit under 7.1.1 to 7.1.4 
 
7.2 
Softening temperature of insulating material 
supporting parts conductively connected to the 
mains carrying a current > 0.2 A at least 150 ºC 
Mains fuse holder 
 
CONSTRUCTIONAL REQUIREMENTS WITH REGARD TO THE PROTECTION 
AGAINST ELECTRIC SHOCK 
 
8.1 
Conductive parts covered by lacquer, paper, 
untreated textile oxide films and beads etc. 
considered to be bare 
 P 
8.2 
No shock hazard when changing voltage setting 
device, fuse-links or handling drawers etc. 
 P 
8.3 
Insulation of hazardous live parts not provided by 
hygroscopic material 
Not used 
8.4 
No risk of electric shock following the removal of a 
cover which can be removed by hand 
  
8.5 
Class 
Ι equipment 
 
Basic insulation between hazardous live parts and 
earthed accessible parts 
 N 
 
Capacitors bridging basic insulation complying with 
14.2.1a 
 N 
 
Basic insulation bridged by components complying 
with 14.3.4.3 
 N 
 
Class 
ΙΙ equipment and Class ΙΙ constructions 
within Class 
Ι equipment 
 N 
 
 
page 6 of 31 
Ref.No.:413858  
IEC 60065 
Clause 
Requirement - Test 
Result - Remark 
Verdict 
 
 
TRF No.: I60065__C 
 
8.6 
Reinforced or double insulation between 
hazardous live parts and accessible parts 
 P 
 
Components bridging reinforced or double 
insulation complying with 14.1 a) or 14.3 
Mains transformer 
 
Basic and supplementary insulation each being 
bridged by a capacitor complying with 14.2.1 a) 
 N 
 
Reinforced or double insulation being bridged with 
2 capacitors in series complying with 14.2.1 a) 
 N 
 
Reinforced or double insulation being bridged with 
a single capacitor complying with 14.2.1 b) 
 N 
8.7 
Basic insulation between parts at 35 V to 71 V 
(peak) a.c. or 60 V to 120 V d.c. and accessible 
parts 
This clause is not considered 
Noted 
 
Reinforced or double insulation between circuits 
operating at between 35 V and 71 V (peak) a.c. or 
between 60 V and 120 V d.c. and hazardous live 
parts at higher voltage 
 N 
 
Separation by Class 
ΙΙ isolating transformer 
 N 
 
Separation by Class 
Ι transformer 
 N 
 
Separation by earthed conductive part 
 
8.8 
Basic or supplementary insulation 
≥ 0.4 mm (mm) : Prim. wires 
 
Reinforced insulation 
≥ 0.4 mm (mm)  ................... : Transformer bobbin 
 
Thin sheet insulation 
 
 
Basic or supplementary insulation, at least two 
layers, each meeting 10.3 
 N 
 
Basic or supplementary insulation, three layers 
any two of which meet 10.3 
 N 
 
Reinforced insulation, two layers each of which 
meet 10.3 
 N 
 
Reinforced insulation, three layers any two which 
meet 10.3 
 N 
8.9 
Adequate insulation between internal hazardous 
live conductors and accessible parts 
Applies to class I - appliances 
 
Adequate insulation between internal hazardous 
live parts and conductors connected to accessible 
parts 
 N 
8.10 
Double insulation between conductors connected 
to the mains and accessible parts 
 P 
 
 
 
page 7 of 31 
Ref.No.:413858  
IEC 60065 
Clause 
Requirement - Test 
Result - Remark 
Verdict 
 
 
TRF No.: I60065__C 
 
8.11 
Detaching of wires 
 
No undue reduction of creepage or clearance 
distances if wires become detached 
No risk of any wire becoming 
detached 
 
Vibration test carried out  ....................................... : No, no need. See above 
8.12 
Adequate cross-sectional area of internal wiring to 
mains socket-outlets 
 N 
8.13 
Adequate fastening of windows, lenses, lamp 
covers etc. (pull test 20 N for 10 s) 
 P 
8.14 
Adequate fastening of covers (pull test 50 N, for 
10 s) 
 P 
8.15 
No risk of damage to the insulation of internal 
wiring due to hot parts or sharp edges 
 P 
8.16 
Only special supply equipment can be used 
 
 
ELECTRIC SHOCK HAZARD UNDER NORMAL OPERATING CONDITIONS 
 
9.1.1 
Touch current measured from terminal devices 
using the network in Annex D  ............................... :
U1 = 0.05Vp (254.4V) 
U2 = 0.01Vp (254.4V) 
 
Discharge not exceeding 45 
µC 
 N 
 
Energy of discharge not exceeding 350 mJ 
 
 
Test with test finger and test probe 
 
9.1.2 
No hazardous live shafts of knobs, handles or 
levers 
 P 
9.1.3 
Ventilation holes tested by means of 
4 mm x 100 mm test pin 
 N 
9.1.4 
Terminal devices tested with 1 mm x 20 mm test 
pin (10 N); test probe 16 of IEC 61032 
 P 
 
Terminal devices tested with 1 mm x 100 mm 
straight wire (1N); test probe D of IEC 61032 
 P 
9.1.5 
Pre-set controls tested with 2.5 mm x 100 mm test 
pin (10 N); test probe C of IEC 61032 
 N 
9.1.6 
No shock hazard due to stored charge on 
withdrawal of the mains plug; voltage (V) after 2 s  :
 N 
 
If C is not greater than 0.1 
µF no test needed 
 P 
 
 
page 8 of 31 
Ref.No.:413858  
IEC 60065 
Clause 
Requirement - Test 
Result - Remark 
Verdict 
 
 
TRF No.: I60065__C 
 
9.1.7 
Enclosure sufficiently resistant to external force 
 
 
Test probe 11 of IEC 61032 for 10 s (50 N) 
 
 
Test hook of fig. 4 for 10 s (20 N) 
 
 
30 mm diameter test tool for 5 s (100 or 250 N)  ... :  
9.2 
No hazard after removing a cover by hand 
 
 
10 INSULATION 
REQUIREMENTS 
 
 
 
(See appended table) 
 
10.1 
Insulation resistance (M
Ω) at least 2 MΩ min. after 
surge test for basic and 4 M
Ω min. for reinforced 
insulation 
>100M
Ω 
10.2 
Humidity treatment 48 h or 120 h 
48 h  
10.3 
Insulation resistance and dielectric strength 
 
 
11 FAULT 
CONDITIONS 
 
    (See 
appended 
table) 
 
11.1 
No shock hazard under fault conditions 
 
11.2 
Heating under fault condition 
 
 
No hazard from softening solder 
 
11.2.1 
Measurement of temperature rises 
 
11.2.2 
Temperature rise of accessible parts 
 
11.2.3 
Temperature rise of parts, other than windings, 
providing electrical insulation 
 P 
 
Temperature rise of printed circuit boards (PCB) 
exceeding the limits of Table 2 by max. 100 K for 
max. 5 min 
 N 
 
a) Temperature rise of printed circuit boards (PCB) 
to 20.1.3, exceeding the limits of Table 2 by not 
more than 100 K for an area not greater than 
2 cm
2
 
 N 
 
b) Temperature rise of printed circuit boards (PCB) 
to 20.1.3 up to 300 K for an area not greater than 
2 cm
2
 for a maximum of 5 min 
 N 
 
Meets all the special conditions if conductors on 
printed circuit boards are interrupted 
At Uin=198V, voltage across 
interruption <50Vp 
(see table 11)
 
11.2.4 
Temperature rise of parts acting as a support or 
mechanical barrier 
 P 