Harman Kardon SB 30 (serv.man2) EMC - CB Certificate ▷ View online
Report No:W-N-1109009-CY-01-1
Telecom Technology Center
13
Report No:W-N-1109009-CY-01-1
Telecom Technology Center
6.2.6 Test Result
Test Mode
Interference
Monitor
Sound
Comment
Mains
Soundbar – L
PASS
Soundbar
Soundbar – L
Soundbar – L
PASS
Soundbar
Auudio In – L
Soundbar – L
PASS
Soundbar
1kHz tone
(Audio In)
Digital Input
Soundbar – L
PASS
Soundbar
Mains
Soundbar – L
PASS
Soundbar
Soundbar – L
Soundbar – L
PASS
Soundbar
Auudio In – L
Soundbar – L
PASS
Soundbar
1kHz tone
(Digital In)
Digital Input
Soundbar – L
PASS
Soundbar
Mains Subwoofer
PASS
Subwoofer
100 Hz tone
(Audio In)
Subwoofer Subwoofer
PASS
Subwoofer
Mains Subwoofer
PASS
Subwoofer
100 Hz tone
(Digital In)
Subwoofer Subwoofer
PASS
Subwoofer
Play back the 1 kHz and 100 Hz tone from the external source into the DUT
14
Report No:W-N-1109009-CY-01-1
Telecom Technology Center
Test Mode: Audio In (1KHz tone)
Monitor:
Monitor:
Speaker
Channel:
AF Level:
793.9 mV
Interference Signal: Mains
7 0
8 0
9 0
1 0 0
1 1 0
1 2 0
1 3 0
1 4 0
1 5 0
0 . 1
1 . 0
1 0 . 0
1 0 0 . 0
dB
uv
(E
M
F)
M H z
Test Mode: Audio In (1KHz tone)
Monitor:
Speaker
Channel:
AF Level:
793.7 mV
Interference Signal: Speaker
7 0
8 0
9 0
1 0 0
1 1 0
1 2 0
1 3 0
1 4 0
1 5 0
0 . 1
1 . 0
1 0 . 0
1 0 0 . 0
dB
uv
(E
M
F)
M H z
15
Report No:W-N-1109009-CY-01-1
Telecom Technology Center
Test Mode: Audio In (1KHz tone)
Monitor:
Speaker
Channel:
AF Level:
794.3 mV
Interference Signal: Audio In ( L )
7 0
8 0
9 0
1 0 0
1 1 0
1 2 0
1 3 0
1 4 0
1 5 0
0 . 1
1 . 0
1 0 . 0
1 0 0 . 0
dB
uv
(E
M
F)
M H z
Test Mode: Audio In (1KHz tone)
Monitor:
Monitor:
Speaker
Channel:
AF Level:
792.3mV
Interference Signal: Digital In
7 0
8 0
9 0
1 0 0
1 1 0
1 2 0
1 3 0
1 4 0
1 5 0
0 . 1
1 . 0
1 0 . 0
1 0 0 . 0
dB
uv
(E
M
F)
M H z
16