Harman Kardon MAS 101-102-111 (serv.man5) EMC - CB Certificate ▷ View online
Date: 2010-09-27
Page 23 of 71
No.: MH184556
3.1.3
Disturbance Power on AC & Signal Port (30MHz to 300MHz)
Test Requirement:
EN 55013
Test Method:
EN 55013
Level:
Table 4
Test Date(s):
2009-07-03
Mode of Operation:
CD Play -Worst case
Test Method:
The test was performed in accordance with EN 55013.
Test Setup:
0.8m
Receiver
EUT
Cable=6m
Absorbing Clamp
Date: 2010-09-27
Page 24 of 71
No.: MH184556
Results and limit lines for Disturbance Power: (POWER LINE)
Limits for Disturbance Power Test, please refer to limit lines (Quasi-Peak and Average) in the following
diagram.
Results: Pass
Please refer to the following diagram for individual results.
Remark:
Calculated measurement uncertainty: 3.55dB
-10
0
10
20
30
40
50
60
70
80
30
50
100
150
200
250
300
L
e
v
e
l
in
d
B
p
W
Frequency in MHz
Date: 2010-09-27
Page 25 of 71
No.: MH184556
Results and limit lines for Disturbance Power: (AUX IN L)
Limits for Disturbance Power Test, please refer to limit lines (Quasi-Peak and Average) in the following
diagram.
Results: Pass
Please refer to the following diagram for individual results.
Remark:
Calculated measurement uncertainty: 3.55dB
-10
0
10
20
30
40
50
60
70
80
30
50
100
150
200
250
300
L
e
v
e
l
in
d
B
p
W
Frequency in MHz
Date: 2010-09-27
Page 26 of 71
No.: MH184556
Results and limit lines for Disturbance Power: (AUX IN R)
Limits for Disturbance Power Test, please refer to limit lines (Quasi-Peak and Average) in the following
diagram.
Results: Pass
Please refer to the following diagram for individual results.
Remark:
Calculated measurement uncertainty: 3.55dB
-10
0
10
20
30
40
50
60
70
80
30
50
100
150
200
250
300
L
e
v
e
l
in
d
B
p
W
Frequency in MHz