DOWNLOAD Harman Kardon MAS 101-102-111 (serv.man5) Service Manual ↓ Size: 1.38 MB | Pages: 73 in PDF or view online for FREE

Model
MAS 101-102-111 (serv.man5)
Pages
73
Size
1.38 MB
Type
PDF
Document
EMC - CB Certificate
Brand
Device
Audio
File
mas-101-102-111-sm5.pdf
Date

Harman Kardon MAS 101-102-111 (serv.man5) EMC - CB Certificate ▷ View online

Date: 2010-09-27 
 
Page 15 of 71 
No.:  MH184556 
 
 
   
 
 
3.1.2 
Conducted Emissions (150KHz to 30MHz) 
 
Test Requirement: 
EN 55013 
 
Test Method: 
EN 55013 
 
Level: 
Table 1 
 
 
 
 
Test Date(s): 
2009-07-02 
 
 
 
 
Mode of Operation: 
FM, CD, USB, TV, AUX, PHONO, LINE IN 
 
Test Method: 
Initial measurements were performed in peak and average detection modes on the live line, any emissions 
recorded within 30dB of the relevant limit lines were re-measured using quasi-peak and average detection 
on the live and neutral lines with the worst case recorded in the table of results.  
The test was performed in accordance with EN 55013. 
Test Setup: 
 
LISN
 
Receiver
 
AE
 
EUT
 
0.8m
 
Cable 
=0.8m
 
 
 
Date: 2010-09-27 
 
Page 16 of 71 
No.:  MH184556 
 
 
   
 
Limits for Conducted Emission: (FM) 
Limits for Conducted Emission Test, please refer to limit lines (Quasi-Peak and Average) in the following 
diagram. 
 
Results: 
Pass 
Please refer to the following diagram for individual results. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Remark:   
Calculated measurement uncertainty: 3.97dB   
 
 
0
   
10
   
20
   
30
   
40
   
50
   
60
   
70
   
80
150k
  
300
400 500       800 1M
2M
3M
4M 5M
6    8
10M
20M
30M
L
e
v
e
l i
n
 d
B
V
Frequency in Hz
Date: 2010-09-27 
 
Page 17 of 71 
No.:  MH184556 
 
 
   
 
Limits for Conducted Emission: (CD) 
Limits for Conducted Emission Test, please refer to limit lines (Quasi-Peak and Average) in the following 
diagram. 
 
Results: 
Pass 
Please refer to the following diagram for individual results. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Remark:   
Calculated measurement uncertainty: 3.97dB 
 
 
0
   
10
   
20
   
30
   
40
   
50
   
60
   
70
   
80
150k
  
300
400 500       800 1M
2M
3M
4M 5M
6    8
10M
20M
30M
L
e
v
e
l i
n
 d
B
V
Frequency in Hz
Date: 2010-09-27 
 
Page 18 of 71 
No.:  MH184556 
 
 
   
 
Limits for Conducted Emission: (USB) 
Limits for Conducted Emission Test, please refer to limit lines (Quasi-Peak and Average) in the following 
diagram. 
 
Results: 
Pass 
Please refer to the following diagram for individual results. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Remark:   
Calculated measurement uncertainty: 3.97dB 
 
 
0
   
10
   
20
   
30
   
40
   
50
   
60
   
70
   
80
150k
  
300
400 500       800 1M
2M
3M
4M 5M
6    8
10M
20M
30M
L
e
v
e
l i
n
 d
B
V
Frequency in Hz
Page of 73
Display

Click on the first or last page to see other MAS 101-102-111 (serv.man5) service manuals if exist.