Harman Kardon HS 500 (serv.man4) EMC - CB Certificate ▷ View online
page 13 of 70
Ref. No. : JSH006020710-002
IEC 60065
Clause
Requirement - Test
Result - Remark
Verdict
14.2
Capacitors and RC units
Pass
Capacitors separately approved
Yes
Pass
14.2.1
Y capacitors tested to IEC 60384-14, 2
nd
edition .. : Y1: CY1, CY2, CY501, CY502
Pass
14.2.2
X capacitors tested to IEC 60384-14, 2
nd
edition .. : X2: C501, C502, C503
Pass
14.2.3
Capacitors operating at mains frequency but not
connected to the mains: tests for X2 ..................... :
connected to the mains: tests for X2 ..................... :
No such component
N/A
14.2.5
Capacitors with volume exceeding 1750 mm³,
where short-circuit current exceeds 0,2 A:
compliance with IEC60384-1, 4.38 category B or
better ....................................................................... :
where short-circuit current exceeds 0,2 A:
compliance with IEC60384-1, 4.38 category B or
better ....................................................................... :
EC502 metal case
N/A
Capacitors with volume exceeding 1750 mm³,
mounted closer to a potential ignition source than
table 5 permits: compliance with IEC 60 384-1,
4.38 category B or better ........................................ :
mounted closer to a potential ignition source than
table 5 permits: compliance with IEC 60 384-1,
4.38 category B or better ........................................ :
EC502 metal case
N/A
Shielded by a barrier to V-0 or metal ..................... : N/A
14.3
Inductors and windings
Pass
Comply with IEC 61558-1, IEC 61558-2
(as relevant) and clause 20.1.4
(as relevant) and clause 20.1.4
N/A
14.3.1
Transformers and inductors marked with
manufacturer’s name and type .............................. :
manufacturer’s name and type .............................. :
Switching mode transformer
T501: BCK-ER4201
T502: BCK-ER2855
Filter L512, L513:
LCL-ET2812
Pass
Transformers and inductors separately approved . : No
N/A
14.3.2 General
Pass
14.3.3 Constructional
requirements
Pass
14.3.3.1
Clearances and creepage distances comply with
clause 13
clause 13
Pass
14.3.3.2
Transformers meet the constructional
requirements
requirements
Pass
page 14 of 70
Ref. No. : JSH006020710-002
IEC 60065
Clause
Requirement - Test
Result - Remark
Verdict
14.3.4.1
Class II transformers have adequate separation
between hazardous live parts and accessible parts
(double or reinforced insulation)
between hazardous live parts and accessible parts
(double or reinforced insulation)
T501 basic insulation
minimum 5.3 mm between
T501 core and primary,
Supplementary insulation
minimum 2.9mm between
T501 core and secondary.
minimum 5.3 mm between
T501 core and primary,
Supplementary insulation
minimum 2.9mm between
T501 core and secondary.
T502 basic insulation
minimum 4.2 mm between
T502 core and primary,
Supplementary insulation
minimum 4.2mm between
T502 core and secondary.
minimum 4.2 mm between
T502 core and primary,
Supplementary insulation
minimum 4.2mm between
T502 core and secondary.
Pass
Coil formers and partition walls > 0,4 mm
T501 bobbin: >0.8mm
T502 bobbin: >0.8mm
Pass
14.3.4.2
Class I transformers, with basic insulation and
protective screening only if all 7 conditions of
14.3.4.2 are met
protective screening only if all 7 conditions of
14.3.4.2 are met
Class II construction
N/A
14.3.4.3
Separating transformers with at least basic
insulation
insulation
N/A
14.3.5.1
Class II transformers have adequate insulation
between hazardous live parts and accessible parts
(double or reinforced insulation)
between hazardous live parts and accessible parts
(double or reinforced insulation)
T501 basic insulation
minimum 5.3 mm between
T501 core and primary,
Supplementary insulation
minimum 2.9mm between
T501 core and secondary.
minimum 5.3 mm between
T501 core and primary,
Supplementary insulation
minimum 2.9mm between
T501 core and secondary.
T502 basic insulation
minimum 4.2 mm between
T502 core and primary,
Supplementary insulation
minimum 4.2mm between
T502 core and secondary.
minimum 4.2 mm between
T502 core and primary,
Supplementary insulation
minimum 4.2mm between
T502 core and secondary.
Pass
Coil formers and partition walls > 0,4 mm
T501 bobbin: >0.8mm
T502 bobbin: >0.8mm
Pass
14.3.5.2
Class I transformers have adequate insulation
between hazardous live parts and accessible
conductive parts or those conductive parts or
protective screens connected to a protective earth
terminal
between hazardous live parts and accessible
conductive parts or those conductive parts or
protective screens connected to a protective earth
terminal
Class II construction
N/A
Winding wires connected to protective earth have
adequate current-carrying capacity
adequate current-carrying capacity
N/A
14.4
High voltage components
No such components
N/A
High-voltage components and assemblies:
U > 4 Kv (peak) separately approved
U > 4 Kv (peak) separately approved
N/A
page 15 of 70
Ref. No. : JSH006020710-002
IEC 60065
Clause
Requirement - Test
Result - Remark
Verdict
Component meets category V-1 of IEC 60707
N/A
14.4.1
High voltage transformers and multipliers tested as
part of the submission
part of the submission
N/A
14.4.2
High voltage assemblies and other parts tested as
part of the submission
part of the submission
N/A
14.5 Protective
devices
Pass
Protective devices used within their ratings
Pass
External clearances and creepage distances meet
requirement of clause 13 for the voltage across the
device when opened
requirement of clause 13 for the voltage across the
device when opened
Fuse F501: >4.0mm
Pass
14.5.1.1
a) Thermal cut-outs separately approved
No such components
N/A
b) Thermal cut-outs tested as part of the
submission
submission
N/A
14.5.1.2
a) Thermal links separately approved
No such components
N/A
b) Thermal links tested as part of the submission
N/A
14.5.1.3
Thermal devices re-settable by soldering
N/A
14.5.2.1
Fuse-links in the mains circuit according to IEC
60127
60127
F501 approved.
Pass
14.5.2.2
Correct marking of fuse-links adjacent to holder ... : F501: T5A L 250V
Pass
14.5.2.3
Not possible to connect fuses in parallel ............... : Only one fuse holder
Pass
14.5.2.4
Not possible to touch hazardous live parts when
replacing fuse-links without the use of a tool ......... :
replacing fuse-links without the use of a tool ......... :
Pass
14.5.3
PTC-S thermistors comply with IEC 60730-1
No such parts
N/A
PTC-S devices (15 W) category V-1 or better
N/A
14.5.4 Circuit
protectors
have adequate breaking capacity
and their position is correctly marked
N/A
14.6
Switches
No such parts
N/A
14.6.1 a)
Separate testing to IEC 61058 including:
10 000 operations
Normal pollution suitability
Resistance to heat and fire level 3
and
V-0 compliance with annex G, G.1.1
N/A
14.6.1 b)
Tested in the apparatus:
N/A
page 16 of 70
Ref. No. : JSH006020710-002
IEC 60065
Clause
Requirement - Test
Result - Remark
Verdict
Switch controlling > 0.2A with open contact
voltage > 35 V (peak)/24 V dc complying with
14.6.3, 14.6.4 and V-0 in annex G, G.1.1
voltage > 35 V (peak)/24 V dc complying with
14.6.3, 14.6.4 and V-0 in annex G, G.1.1
N/A
Switch controlling > 0.2A with open contact
voltage < 35 V (peak)/24 V dc complying with
14.6.3 and V-0 in annex G, G.1.1
voltage < 35 V (peak)/24 V dc complying with
14.6.3 and V-0 in annex G, G.1.1
N/A
Switch controlling < 0.2A with open contact
voltage > 35 V (peak)/24 V dc complying with
14.6.4 and V-0 in annex G, G.1.1
voltage > 35 V (peak)/24 V dc complying with
14.6.4 and V-0 in annex G, G.1.1
N/A
14.6.2
Switch tested to 14.6.1 b) constructed to IEC
61058-1 subclause 13.1 and has making/breaking
action independent of speed of actuation
61058-1 subclause 13.1 and has making/breaking
action independent of speed of actuation
N/A
14.6.3
Switch tested to 14.6.1 b) compliant with IEC
61058-1 subclause 16.2.2 d) and m) not attaining
excessive temperatures in use
61058-1 subclause 16.2.2 d) and m) not attaining
excessive temperatures in use
N/A
14.6.4
Switch tested to 14.6.1 b) has adequate dielectric
strength
strength
N/A
14.6.5
Mains switch controlling mains socket outlets
additional tests to IEC 60058-1
additional tests to IEC 60058-1
N/A
Socket outlet current marking correct
N/A
14.7
Safety interlocks
No such parts
N/A
Safety interlocks to 2.8 of IEC 60950
N/A
14.8
Voltage setting devices
No such parts
N/A
Voltage setting device not likely to be changed
accidentally
accidentally
N/A
14.9 Motors
N/A
14.9.1
Endurance test on motors
Only low voltage DC servo
motor in DVD loader
motor in DVD loader
N/A
Motor start test
N/A
Dielectric strength test
N/A
14.9.2
Not adversely affected by oil or grease etc.
N/A
14.9.3
Protection against moving parts
N/A
14.9.4
Motors with phase-shifting capacitors, three-phase
motors and series motors meet clause. B.8, B.9
and B.10 of IEC 60950, Annex B
motors and series motors meet clause. B.8, B.9
and B.10 of IEC 60950, Annex B
N/A
14.10 Batteries
Pass
14.10.1
Batteries mounted with no risk of accumulation of
flammable gases
flammable gases
Only non-rechargeable alkali
batteries in IR remote
controller.
batteries in IR remote
controller.
Pass
Click on the first or last page to see other HS 500 (serv.man4) service manuals if exist.