Report No. JSH006020710-002
Amendment 1, March 12, 2007
Test case verdicts
Test case does not apply to the test object.................. : N(.A.)
Test item does meet the requirement .......................... : P(ass)
Test item does not meet the requirement .................... : F(ail)
Testing
Date of receipt of test item ........................................... :
Date(s) of performance of test………………………:
March 12, 2007
March 12, 2007 – March 12, 2007
General remarks
This report is not valid as a CB Test Report unless signed by an approved CB Testing Laboratory and
appended to a CB Test Certificate issued by a NCB, in accordance with IECEE 02.
This report shall not be reproduced except in full without the written approval of the testing laboratory.
The test results presented in this report relate only to the item(s) tested.
"(see appended table)" refers to a table appended to the report.
“(see remark #)” refers to a remark appended to the report.
“(see Annex #) refers to an annex appended to the report.
Throughout this report a point is used as the decimal separator.
This report is not valid as a CB Test Report unless signed by an approved CB Testing Laboratory and
appended to a CB Test Certificate issued by a NCB, in accordance with IECEE 02.
This report shall not be reproduced except in full without the written approval of the testing laboratory.
The test results presented in this report relate only to the item(s) tested.
"(see appended table)" refers to a table appended to the report.
“(see remark #)” refers to a remark appended to the report.
“(see Annex #) refers to an annex appended to the report.
Throughout this report a point is used as the decimal separator.
Amendment 1:
The original test report ref. No. JSH006020710-002, dated March 30, 2006 was modified on March 12,
2003 to include the following changes and/or additions:
2003 to include the following changes and/or additions:
1. The applicant’s name is changed. After review, no additional tests were considered necessary.
2. Factory’s name and address is changed as followed; After review, no additional tests were
considered necessary
Factory name: WANLIDA GROUP CO., LTD.
Factory address: WANLIDA INDUSTRY ZONE, NANJING, FUJIAN, CHINA.
Summary of Testing and Conclusions
The sample(s) tested complies with the requirements of IEC 60065_2001.