Harman Kardon HK 3390 (serv.man2) EMC - CB Certificate ▷ View online
Reference No. : 54120801G Page 52
◀ Anam EMC Test Laboratory ▶
Annex D: Flicker
Reference No.: 54120801H
Page 2
CONTENTS
Page
1. Client information
3
2. Equipment under test (EUT)
3
2.1 Identification of the EUT
2.2 Additional information about the EUT
3. Test specifications
4
3.1 Standards
3.2 Additions,deviations and exclusions from standards
3.3 Purpose of the test
4. Test summary
4
5. Input immunity to RF voltages(in differential mode):S1
5
5.1 Test criteria and test procedure
5.2 Measurement uncertainty
5.3 Test result
6. Immunity to RF voltages:S2a
6
6.1 Test criteria and test procedure
6.2 Measurement uncertainty
6.3 Test result
7. Immunity to RF voltages (in common mode):S2b
7
7.1 Test criteria and test procedure
7.2 Measurement uncertainty
7.3 Test result
8. Immunity to ambient electromagnetic fields:S3
8
8.1 Test criteria and test procedure
8.2 Measurement uncertainty
8.3 Test result
9. Screening effectiveness:S4
9
9.1 Test criteria and test procedure
9.2 Measurement uncertainty
9.3 Test result
10. Test instrumentation
10
Annex-Measurement Data;
Annex A
: Input immunity to RF voltages(in differential mode)
11
Annex B
: Immunity to RF voltage 24
Annex C
: Immunity to RF voltage(in common mode)
39
Annex D
: Immunity to ambient electromagnetic fields
45
Annex E
: Screening effectiveness
49
◀
Anam EMC Test Laboratory ▶
Reference No.: 54120801H
Page 3
1. CLIENT INFORMATION
The EUT has been test by request of:
* Company
: Harman Consumer Group
8500 Balboa Blvd., Northridge, CA 91329, USA
8500 Balboa Blvd., Northridge, CA 91329, USA
* Contact Person
: Mr. Patrick Zarrabi
* Tel.
: +1-818-895-8161
2. EQUIPMENT UNDER TEST(EUT)
2.1 Identification of the EUT
*Equipment
: Stereo Receiver
*Model No.
: HK3390/230
*Brand Name
: Harman/Kardon
*Serial No.
: N/A
*Manufacturer
: DongGuan LiaoBu Anam Electronics
(China)
Xin Cheng Management Area, Liaobu Town,
Dongguan City, Guang Dong Province, China
Fax: 86-769-3216338 Tel: 86-769-3326888
Dongguan City, Guang Dong Province, China
Fax: 86-769-3216338 Tel: 86-769-3326888
*Power Rating
AC 220-230V, 50Hz/60Hz, 280W
*External signal
Speaker1 L,R, Speaker2 L,R
In/Out terminal
Audio : PHONO, CD, TAPE IN/OUT,VID1 IN/OUT
VID2/DVD IN, VID3
Video : VID1 IN/OUT, VID2/DVD, VID3, MONITOR
VID2/DVD IN, VID3
Video : VID1 IN/OUT, VID2/DVD, VID3, MONITOR
Remote IN/OUT, Trigger out 1,2
SUB-OUT
VID4 Audio L/R, VIDEO
SUB-OUT
VID4 Audio L/R, VIDEO
*Tuner Section
: FM 87.5㎒ ~ 108㎒ (50㎑ Steps)
: AM 522㎑ ~ 1,620㎑ (9㎑ Steps)
: AM 522㎑ ~ 1,620㎑ (9㎑ Steps)
2.2 Additional information about the EUT
The EUT consists of the following subsystems/modules/parts; none
The tests have been performed on the EUT provided with the following
modifications; none
The tests have been performed on the EUT provided with the following
modifications; none
◀
Anam EMC Test Laboratory ▶
Click on the first or last page to see other HK 3390 (serv.man2) service manuals if exist.