Harman Kardon HK 3390 (serv.man2) EMC - CB Certificate ▷ View online
Reference No. : 54120801G Page 36
◀ Anam EMC Test Laboratory ▶
6DB
ANAM EMC Testing Lab.
30 MHz
300 MHz
dBµV
dBµV
1 PK
CLRWR
2 AV
CLRWR
SGL
RBW
120 kHz
MT
100 µs
PREAMP OFF
Att 10 dB AUTO
18.Dec 07 14:40
80 MHz
120 MHz
160 MHz
200 MHz
240 MHz
280 MHz
0
10
20
30
40
50
60
70
80
1
Marker 1 [T1 ]
24.81 dBµV
126.280000000 MHz
A7_AV
A7_QP
HK3390_VID 2,3,MONITOR OUT
Date: 18.DEC.2007 14:40:07
Reference No. : 54120801G Page 37
◀ Anam EMC Test Laboratory ▶
6DB
ANAM EMC Testing Lab.
30 MHz
300 MHz
dBµV
dBµV
1 PK
CLRWR
2 AV
CLRWR
SGL
18.Dec 07 14:43
RBW
120 kHz
MT
100 µs
PREAMP OFF
Att 10 dB AUTO
80 MHz
120 MHz
160 MHz
200 MHz
240 MHz
280 MHz
0
10
20
30
40
50
60
70
80
1
Marker 1 [T1 ]
28.62 dBµV
126.280000000 MHz
A7_AV
A7_QP
HK3390_REMOTE IN
Date: 18.DEC.2007 14:43:22
Reference No. : 54120801G Page 38
◀ Anam EMC Test Laboratory ▶
6DB
ANAM EMC Testing Lab.
30 MHz
300 MHz
dBµV
dBµV
1 PK
CLRWR
2 AV
CLRWR
SGL
18.Dec 07 14:43
RBW
120 kHz
MT
100 µs
PREAMP OFF
Att 10 dB AUTO
80 MHz
120 MHz
160 MHz
200 MHz
240 MHz
280 MHz
0
10
20
30
40
50
60
70
80
1
Marker 1 [T1 ]
29.36 dBµV
126.280000000 MHz
A7_AV
A7_QP
HK3390_REMOTE OUT
Date: 18.DEC.2007 14:43:32
Reference No. : 54120801G Page 39
◀ Anam EMC Test Laboratory ▶
6DB
ANAM EMC Testing Lab.
30 MHz
300 MHz
dBµV
dBµV
1 PK
CLRWR
2 AV
CLRWR
SGL
18.Dec 07 14:46
RBW
120 kHz
MT
100 µs
PREAMP OFF
Att 10 dB AUTO
80 MHz
120 MHz
160 MHz
200 MHz
240 MHz
280 MHz
0
10
20
30
40
50
60
70
80
1
Marker 1 [T1 ]
27.22 dBµV
80.000000000 MHz
A7_AV
A7_QP
HK3390_TRIGER 1
Date: 18.DEC.2007 14:46:25
Click on the first or last page to see other HK 3390 (serv.man2) service manuals if exist.