Reference No. : 54120801G                                                                                                                        Page 12
 
◀  Anam EMC Test Laboratory  ▶
 
 
7.5. Test protocols 
 
Date: January 11, 2008 
 
Antenna terminal disturbance voltage due to the local oscillator. 
Channel Harmonic 
Measured 
freq. (㎒) 
Limit(㏈㎶) 
Disturbance 
value(㏈㎶) 
 1 
98.2 
54.0 
39.4 
 2 
196.4 
50.0 
45.3 
 3 
294.6 
50.0 
38.1 
 4 
392.8 
52.0 
87.5 5 491.0 
52.0 
37.2 
 6 
589.2 
52.0 
33.8 
 7 
687.4 
52.0 
47.2 
 8 
785.6 
52.0 
36.8 
 9 
883.8 
52.0 
 10 
982.0 
52.0 
 1 
108.7 
54.0 
40.3 
 2 
217.4 
50.0 
45.6 
 3 
326.1 
52.0 
41.6 
98.0 4 434.8 
52.0 
36.4 
 5 
543.5 
52.0 
41.6 
 6 
652.2 
52.0 
35.7 
 7 
760.9 
52.0 
38.5 
 8 
869.6 
52.0 
36.5 
 9 
978.3 
52.0 
32.3 
 1 
118.7 
54.0 
40.6 
 2 
237.4 
50.0 
46.6 
 3 
356.1 
52.0 
43.5 
108.0 4 474.8 
52.0 36.4 
 5 
593.5 
52.0 
44.0 
 6 
712.2 
52.0 
37.9 
 7 
830.9 
52.0 
40.3 
 8 
949.6 
52.0 
33.8 
 
 
 
 
Reference No. : 54120801G                                                                                                                        Page 13
 
◀  Anam EMC Test Laboratory  ▶
 
 
OTHERS 
Antenna terminal disturbance voltage due to other source than local oscillator. 
Channel Harmonic 
Measured 
freq. (㎒) 
Limit(㏈㎶) 
Disturbance 
value(㏈㎶) 
98.0   / 46.0 * 
 
*: less than 30 ㏈㎶ 
    
 
 
 
Limit 
according 
to 
EN55013:2001+A2(2006) 
 
8. DISTURBANCE POWER 
8.1. Operating environment 
Temperature 
: 22℃ 
Relative humidity  : 50% 
 
      8.2. Test set-up and procedure 
 
The EUT was placed on a non-metallic table of 0.8m height. At the side of the 
 
EUT a non-metallic table of 6m length was placed to provide for movement of 
 
the absorbing clamp. The absorbing clamp was applied successively to all leads 
 
whose length was 25 ㎝  or longer, unscreened or screened. For the read, the 
 
maximum measured value at each frequency which was obtained when the 
 
absorbing clamp is moved along the lead was registered. No metallic object, 
 
including a possible other unit of the EUT or any person, was closer to the lead 
 
or unit than 0.8m. All screened and unscreened cables were measured with an 
absorbing clamp, according to EN55013, 5.6. 
 
   8.3. Measurement uncertainty 
 
Radio interference power:  ±2.0 ㏈ 
 
The Measurement uncertainty describes the overall uncertainty of the given   
measured value during operation of the EUT in the above-mentioned way. 
 
   8.4. Test instrumentation 
Equipment 
Manufacturer 
Type No. 
Serial No. 
Measurement 
receiver 
R & S 
ESCI 
100348 
R. C. Oscillator 
Kenwood 
AG-203A 
3090241 
Absorbing clamp 
R & S 
MDS 21 
860846/006 
 
 
 
 
 
* R & S: Rohde & Schwarz 
 
 
 
Reference No. : 54120801G                                                                                                                        Page 14
 
◀  Anam EMC Test Laboratory  ▶
 
 
8.5. Test protocols 
 
Date: December 18, 2007 
 
The equipment does comply with the requirements. Operating condition: The   
 
EUT continuously operated with audio frequency of 1,000 ㎐ color bar being 
 
supplied from the Oscillator or test DVD. An absorbing clamp was placed 
 
around all leads. At each mode, the maximum value at each testing frequency 
 
and each output lead was registered and attached as follows. 
Limit(㏈㎺) Result(㏈㎺) 
Test Lead 
Freq. 
(㎒) 
QP AV QP  AV 
PHONO 126.28 
48.6 38.6 31.4  30.4 
TAPE IN 
126.28 
48.6 38.6 30.4  29.5 
TAPE OUT 
126.28 
48.6 38.6 30.5  30.5 
VID1 IN 
126.28 
48.6 38.6 30.6  30.4 
VID 1 OUT 
126.28 
48.6 38.6 31.3  30.3 
VID 2 
126.28 
48.6 38.6 32.1  31.2 
VID 3 
126.28 
48.6 38.6 30.3  30.0 
VID 1 IN/OUT 
126.28 
48.6 38.6 30.5  30.3 
VID 2,3,MONITOR 
126.28 
48.6 38.6 30.2  30.1 
REMOTE IN 
126.28 
48.6 38.6 30.9  30.6 
REMOTE OUT 
126.28 
48.6 38.6 30.5  30.2 
TRIGGER 1 
80.00 
46.8 
36.8 
28.9 
27.7 
TRIGGER 2 
80.00 
46.8 
36.8 
28.8 
27.5 
SUB OUT 
126.28 
48.6 38.6  * 
SPEAKER 1 L 
126.28 
48.6 38.6  * 
SPEAKER 1 R 
126.28 
48.6 38.6  * 
SPEAKER 2 L 
126.28 
48.6 38.6  * 
SPEAKER 2 R 
126.28 
48.6 38.6  * 
PHONES 126.28 
48.6 38.6 35.4  35.1 
FRONT AUDIO, VIDEO  126.28 
48.6 38.6 25.5  * 
AC POWER CORD 
126.28 
48.6 38.6  * 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Reference No. : 54120801G                                                                                                                        Page 15
 
◀  Anam EMC Test Laboratory  ▶
 
 
 
 
 
 
 
*: less than 25 ㏈㎺ 
    
Limit 
according 
to 
EN55013:2001+A2(2006)
 
 
Note:1) The spectrum was checked from 30 to 300 ㎒. 
 
     2) The cable (6.0m length) loss is included in a correction factor. 
 
     3) Detector function of the measuring instrument:  
 
 
QP: Quasi-peak, AV: Average 
 
     4) QP line: Limit (㏈㎺) = Frequency (㎒)  ×0.037 + 43.9 
 
              AV line: Limit (㏈㎺) = Frequency (㎒)  ×0.037 + 33.9 
 
     5) *: Less than 25 ㏈㎺ 
 