Harman Kardon HD 990 (serv.man5) EMC - CB Certificate ▷ View online
Test report no. SH08090332-001
Page 8 of 76
2.3 Instrument List
Instrument
Code Model Due date
EMI test receiver
EC 2107
ESCS 30
2009-1-22
A.M.N.
EC
3119 ESH2-Z5 2009-1-22
A.M.N.
EC 3394
ENV 216
2008-10-17
Voltage probe
EC 2107-1
ESH2-Z6
2009-1-22
Absorbing clamp
EC 2108
MDS 21
2009-1-25
Tri-loop
EC 3384
HXYZ 9170
2008-6-3
Harmonic/Flicker sys. EC 2110
5001ix/PACS-1 2009-1-22
CDN
EC
2113-1
M216
2009-1-22
CDN
EC
2113-2
M316
2009-1-22
Induction coil
EC 2114-1
INA 701
2008-7-18
Click meter
EC 2253
CL55C
2008-8-22
Signal generator
EC 2338
SML 01
2009-1-22
Lum. Meter
EC 2451
TES 1332
2008-6-16
ESD Gun
EC 2956
ditto
2009-1-23
Motorise Variac
EC 2957
MV 2616
Not required
Immunity system
EC 2958
UCS500M6
2009-2-8
Capacitive clamp
EC 2959
HFK
Not required
Immunity system
EC 2960
TSS500M
2009-1-22
Immunity system
EC 2961
TSS500M4
2009-1-22
Power amplifier
EC 3043-1
75A250
2008-8-22
CDN
EC
3043-2
T2
2009-1-22
Attenuator
EC
3043-3
ATT6/75 2009-1-22
CDN
EC
3043-4
T4
2009-1-22
DDC
EC
3043-5
DC2600 2009-1-22
EM clamp
EC 3043-6
EM 101
2008-8-21
Power sensor
EC 3043-7
PH 2000
2009-1-22
Power meter
EC 3043-8
PM 2002
2009-1-22
Attenuator
EC
3043-9
68-6-44 2009-1-22
Impedance
EC
3043-10
R100
2009-1-22
Impedance
EC
3043-11
R100
2009-1-22
Impedance
EC
3043-12
R50
2009-1-22
Signal generator
EC 3044-1
SMR20
2008-8-21
Test report no. SH08090332-001
Page 9 of 76
Power amplifier
EC 3044-2
150W1000
2008-8-21
Field sensor
EC 3044-3
FP6001
2008-8-21
Power amplifier
EC 3044-4
25S1G4
2008-8-21
DDC
EC
3044-5
DC6180A 2009-1-22
DDC
EC
3044-6
DC7144A 2009-1-22
Log-periodical antenna EC 3044-7
AT1080
2008-8-21
Horn antenna
EC 3044-8
AT4002
2008-8-21
Field meter
EC 3044-9
FM5004
2008-8-21
EMI test receiver
EC 3045
ESIB26
2008-6-30
Broadband antenna
EC 3046-1
HL562
2008-6-30
Broadband antenna
EC 3046-2
HL562
2008-6-30
Fully anechoic chamber EC 3047
-
2008-6-16
Semi anechoic chamber EC 3048
-
2008-6-16
Horn antenna
EC 3049
HF906
2008-6-30
ISN
EC 3218
ENY 22
2009-1-22
ISN
EC 3220
ENY 41
2009-1-22
Current probe
EC 3221
EZ-17
2009-1-22
Pre-amplifier
EC 3222
pre-amp 18
2008-7-1
Shielded room
EC 2838
GB88
2009-2-3
Shielded room
EC 2839
GB88
2009-2-3
Thermo-Hygrograph
EC
3323 ZJ1-2A 2008-4-2
Thermo-Hygrograph
EC
3324 ZJ1-2A 2008-4-2
Thermo-Hygrograph
EC
3325 ZJ1-2A 2008-11-15
Thermo-Hygrograph
EC
3326 ZJ1-2A 2008-11-15
Air pressure indicator
EC 3320
YM3
2009-3-5
Isolation transformer
EC 2100
-
Not required
Oscilloscope
EC 2614
TDS3012B
2009-1-16
Test report no. SH08090332-001
Page 10 of 76
2.4 Test Summary
This report applies to tested sample only. This report shall not be reproduced in
part without written approval of Intertek Testing Service Shanghai Limited.
part without written approval of Intertek Testing Service Shanghai Limited.
TEST ITEM
RESULT
NOTE
Disturbance voltage at the mains terminals
Pass
Disturbance voltage at the antenna terminals
NA
Disturbance power
Pass
Radiated emission
NA
Harmonics Pass
Flicker Pass
S1 NA
S2 Pass
S3 Pass
S4 NA
ESD Pass
EFT Pass
S5 Pass
Notes: NA =Not Applicable
Test report no. SH08090332-001
Page 11 of 76
Emission Test
3. Disturbance voltage at the mains terminals
Test result:
PASS
3.1 Limits of disturbance voltage at the mains terminals
Frequency range
(MHz)
Limits dB(
µv)
Quasi-peak Average
0.15 ~ 0.5
66 ~ 56 *
56 ~ 46 *
0.5 ~ 5
56
46
5 ~ 30
60
50
Note: 1. * means the limit decreasing linearly with the logarithm of the frequency.
2. If the limits for the average detector are met when using the quasi-peak
detector, then the limits for the measurements with the average detector
are considered to be met.
are considered to be met.
3.2 Test setup