Harman Kardon HD 990 (serv.man5) EMC - CB Certificate ▷ View online

 
Test report no. SH08090332-001 
 
 
Page 8 of 76 
 
 
2.3 Instrument List 
 
  
Instrument  
        Code                  Model                 Due date 
 
 
 
EMI test receiver 
EC 2107 
ESCS 30 
2009-1-22 
 A.M.N. 
EC 
3119 ESH2-Z5 2009-1-22 
 
A.M.N. 
EC 3394 
ENV 216 
2008-10-17 
 
 
Voltage probe 
EC 2107-1 
ESH2-Z6 
2009-1-22 
 
 
Absorbing clamp 
EC 2108 
MDS 21 
2009-1-25 
 
 
Tri-loop 
EC 3384 
HXYZ 9170 
2008-6-3 
 
 
Harmonic/Flicker sys.  EC 2110 
5001ix/PACS-1 2009-1-22 
 
 CDN 
EC 
2113-1 
M216 
2009-1-22 
 
 CDN 
EC 
2113-2 
M316 
2009-1-22 
 
 
Induction coil 
EC 2114-1 
INA 701 
2008-7-18 
 
 
Click meter 
EC 2253 
CL55C 
2008-8-22 
 
 
Signal generator 
EC 2338 
SML 01 
2009-1-22 
 
 
Lum. Meter 
EC 2451 
TES 1332 
2008-6-16 
 
 
ESD Gun 
EC 2956 
ditto 
2009-1-23 
 
 
Motorise Variac 
EC 2957 
MV 2616 
Not required 
 
 
Immunity system 
EC 2958 
UCS500M6 
2009-2-8 
 
 
Capacitive clamp 
EC 2959 
HFK 
Not required 
 
 
Immunity system 
EC 2960 
TSS500M 
2009-1-22 
 
 
Immunity system 
EC 2961 
TSS500M4 
2009-1-22 
 
 
Power amplifier 
EC 3043-1 
75A250 
2008-8-22 
 
 CDN 
EC 
3043-2 
T2 
2009-1-22 
 
 Attenuator 
 
EC 
3043-3 
ATT6/75 2009-1-22 
 
 CDN 
EC 
3043-4 
T4 
2009-1-22 
 
 DDC 
EC 
3043-5 
DC2600  2009-1-22 
 
 
EM clamp 
EC 3043-6 
EM 101 
2008-8-21 
 
 
Power sensor 
EC 3043-7 
PH 2000 
2009-1-22 
 
 
Power meter 
EC 3043-8 
PM 2002 
2009-1-22 
 
 Attenuator 
EC 
3043-9 
68-6-44  2009-1-22 
 
 Impedance 
EC 
3043-10 
R100 
2009-1-22 
 
 Impedance 
EC 
3043-11 
R100 
2009-1-22 
 
 Impedance 
EC 
3043-12 
R50 
2009-1-22 
 
 
Signal generator 
EC 3044-1 
SMR20 
2008-8-21 
 
Test report no. SH08090332-001 
 
 
Page 9 of 76 
 
 
Power amplifier 
EC 3044-2 
150W1000 
2008-8-21 
 
 
Field sensor 
EC 3044-3 
FP6001 
2008-8-21 
 
 
Power amplifier 
EC 3044-4 
25S1G4 
2008-8-21 
 
 DDC 
EC 
3044-5 
DC6180A 2009-1-22 
 
 DDC 
EC 
3044-6 
DC7144A 2009-1-22 
 
 
Log-periodical antenna  EC 3044-7 
AT1080 
2008-8-21 
 
 
Horn antenna 
EC 3044-8 
AT4002 
2008-8-21 
 
 
Field meter 
EC 3044-9 
FM5004 
2008-8-21 
 
 
EMI test receiver 
EC 3045 
ESIB26 
2008-6-30 
 
 
Broadband antenna 
EC 3046-1 
HL562 
2008-6-30 
 
 
Broadband antenna 
EC 3046-2 
HL562 
2008-6-30 
 
 
Fully anechoic chamber  EC 3047 
2008-6-16 
 
 
Semi anechoic chamber  EC 3048 
2008-6-16 
 
 
Horn antenna 
EC 3049 
HF906 
2008-6-30 
 
 
ISN 
EC 3218 
ENY 22 
2009-1-22 
 
 
ISN 
EC 3220 
ENY 41 
2009-1-22 
 
 
Current probe 
EC 3221 
EZ-17 
2009-1-22 
 
 
Pre-amplifier 
EC 3222 
pre-amp 18 
2008-7-1 
 
 
Shielded room 
EC 2838 
GB88 
2009-2-3 
 
 
Shielded room 
EC 2839 
GB88 
2009-2-3 
 
 Thermo-Hygrograph 
EC 
3323 ZJ1-2A  2008-4-2 
 
 Thermo-Hygrograph 
EC 
3324 ZJ1-2A  2008-4-2 
 
 Thermo-Hygrograph 
EC 
3325 ZJ1-2A  2008-11-15 
 
 Thermo-Hygrograph 
EC 
3326 ZJ1-2A  2008-11-15 
 
 
Air pressure indicator 
EC 3320 
YM3 
2009-3-5 
 
 
Isolation transformer 
EC 2100 
Not required 
 
 
Oscilloscope  
EC 2614 
TDS3012B 
2009-1-16 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Test report no. SH08090332-001 
 
 
Page 10 of 76 
 
 
 
2.4 Test Summary 
 
This report applies to tested sample only.  This report shall not be reproduced in 
part without written approval of Intertek Testing Service Shanghai Limited. 
 
                 TEST ITEM 
RESULT 
NOTE 
Disturbance voltage at the mains terminals 
Pass 
 
Disturbance voltage at the antenna terminals 
NA 
 
Disturbance power 
Pass 
 
Radiated emission 
NA 
 
Harmonics Pass 
 
Flicker Pass 
 
S1 NA 
 
S2 Pass 
 
S3 Pass 
 
S4 NA 
 
ESD Pass 
 
EFT Pass 
 
S5 Pass 
 
 
 
Notes: NA =Not Applicable 
 
Test report no. SH08090332-001 
 
 
Page 11 of 76 
Emission Test 
 
3. Disturbance voltage at the mains terminals 
 
Test   result: 
PASS
 
 
3.1 Limits of disturbance voltage at the mains terminals 
 
Frequency range 
(MHz) 
Limits dB(
µv) 
               Quasi-peak                            Average 
 
0.15 ~ 0.5 
66 ~ 56 * 
56 ~ 46 * 
0.5 ~ 5 
56 
46 
5 ~ 30 
60 
50 
 
Note: 1. * means the limit decreasing linearly with the logarithm of the frequency.
          2. If the limits for the average detector are met when using the quasi-peak 
detector, then the limits for the measurements with the average detector 
are considered to be met. 
 
 
 
3.2 Test setup 
 
 
 
 
 
 
 
 