Harman Kardon HD 990 (serv.man5) EMC - CB Certificate ▷ View online
Test report no. SH08090332-001
Page 12 of 76
3.3 Test Setup and Test Procedure
Measurement was performed in shielded room.
Instruments used were following CISPR 16-1.
Measurement methods and operation conditions of EUT was according to clause 5.2
Instruments used were following CISPR 16-1.
Measurement methods and operation conditions of EUT was according to clause 5.2
and 5.3 of EN55013
Frequency range 150kHz – 30MHz was checked and EMI receiver measurement’s
bandwidth was set to 9 kHz.
3.4 Emission waveform
L:
Test report no. SH08090332-001
Page 13 of 76
N:
Test report no. SH08090332-001
Page 14 of 76
3.5 Test Protocol
Temperature :
22
°C
Relative Humidity
:
46 %
L line
N line
Test report no. SH08090332-001
Page 15 of 76
3.6 Measurement Uncertainty
The measurement uncertainty describes the overall uncertainty of the given measured
value during the operation of the EUT.
Measurement uncertainty at mains terminal:
value during the operation of the EUT.
Measurement uncertainty at mains terminal:
± 1.99dB
The measurement uncertainty is given with a confidence of 95%, k=2.
The measurement uncertainty is traceable to internal procedure TI-036.
The measurement uncertainty is traceable to internal procedure TI-036.