Harman Kardon HD 990 (serv.man5) EMC - CB Certificate ▷ View online
Test report no. SH08090332-001
Page 60 of 76
16.4 Test Protocol
Temperature
:
22
°C
Relative Humidity:
40%
Air
Pressure:
101kPa
Direct discharges were applied at the following selected points:
Test point
#
Test level
[kV]
Air/
Contact
Polarity
(+/-)
Pass/
Fail
Comment
A
2/4
Contact
+/-
P
All touchable screws of enclosure
B 2/4
Contact
+/-
P
Accessible metal parts of the EUT
C
2/4/8
Air
+/-
P
Air gap of the switch, button
D
2/4/8
Air
+/-
P
The air in-taking opening
E
2/4/8
Air
+/-
P
Slots around the EUT
Indirect contact discharges were applied to the VCP and the HCP at the following
selected points:
selected points:
For table top equipment
Point Description
Point Result
HCP f 0,1m from the front of the EUT
Edge of centre,corner on HCP
Pass
HCP b 0,1m from the back of the EUT
Edge of centre,corner on HCP
Pass
HCP r 0,1m from the right side of the EUT Edge of centre,corner on HCP
Pass
HCP l 0,1m from the left side of the EUT
Edge of centre,corner on HCP
Pass
VCP f 0,1m from the front of the EUT
Edge of centre,corner on VCP
Pass
VCP b 0,1m from the back of the EUT
Edge of centre,corner on VCP
Pass
VCP r 0,1m from the right of the EUT
Edge of centre,corner on VCP
Pass
VCP l 0,1m from the left of the EUT
Edge of centre,corner on VCP
Pass
For floor standing equipment
Point Description
Point Result
VCP f 0,1m from the front of the EUT
Edge of centre,corner on VCP
-
VCP b 0,1m from the back of the EUT
Edge of centre,corner on VCP
-
VCP r 0,1m from the right of the EUT
Edge of centre,corner on VCP
-
VCP l 0,1m from the left of the EUT
Edge of centre,corner on VCP
-
Observation: The apparatus shall continue to operate as intended after the test.
Conclusion: The EUT met the requirements of Performance B
Test report no. SH08090332-001
Page 61 of 76
16.5 ESD Test point:
16.6 Measurement Uncertainty
The measurement uncertainty describes the overall uncertainty of the given measured
value during the operation of the EUT.
Measurement uncertainty of ESD test is:
value during the operation of the EUT.
Measurement uncertainty of ESD test is:
± 7 %
The measurement uncertainty is given with a confidence of 95%, k=2.
The measurement uncertainty is traceable to internal procedure TI-036.
The measurement uncertainty is traceable to internal procedure TI-036.
16.7 Additions, Deviations and Exclusions from Standards
None
Test report no. SH08090332-001
Page 62 of 76
17. Immunity requirements for RF e.m. field Keyed carrier
Test result:
Pass
17.1 Severity Level and Performance Criterion
17.1.1 Test level
Frequency
(MHz)
Level
(V/m)
900 (Duty cycle 1/9, 217Hz repetition
frequency)
3
Note: As an alternative method, a non-homogeneous field strength ≥3 V/m of similar
characteristics as the test specification (e.g. generated by a dummy GSM portable
telephone) may be applied in a shielded room.
The dummy shall be placed on a non-metallic stand with a height of 80 cm, at a
distance of 1 m to the EUT (see Figure 11). The front side of the EUT shall be
placed in parallel to the antenna line of sight. The position shall be described in the
measurement report.
In case of dispute, measurements shall be carried out in accordance with IEC
61000-4-3, with measurement conditions given in 5.8.4 and Table 23, and filter B.2
replaced by B.4.
telephone) may be applied in a shielded room.
The dummy shall be placed on a non-metallic stand with a height of 80 cm, at a
distance of 1 m to the EUT (see Figure 11). The front side of the EUT shall be
placed in parallel to the antenna line of sight. The position shall be described in the
measurement report.
In case of dispute, measurements shall be carried out in accordance with IEC
61000-4-3, with measurement conditions given in 5.8.4 and Table 23, and filter B.2
replaced by B.4.
17.1.2 Performance Criterion
Performance criterion: A
Test report no. SH08090332-001
Page 63 of 76
17.2 Block diagram of test setup
17.3 Test Setup and Test Procedure
Measurement was performed in shielded room.
Instruments used were following CISPR 16-1 and EN 55020.
Measurement methods and operation conditions of EUT was according to clause 5.1,
Instruments used were following CISPR 16-1 and EN 55020.
Measurement methods and operation conditions of EUT was according to clause 5.1,
5.2 and 5.8 of EN55020.
Antenna
mast
mast
Power meter
Field monitor
Table
Amplifier
Signal generator
EUT
Field probe
Optical fiber
AE