Test report no. SH08090332-001 
 
 
Page 60 of 76 
16.4 Test Protocol 
 
Temperature  
22
°C  
Relative Humidity: 
40% 
 Air 
Pressure:   
101kPa 
 
Direct discharges were applied at the following selected points: 
 
Test point 
Test level 
[kV] 
Air/ 
Contact
Polarity
(+/-) 
Pass/
Fail 
Comment 
2/4 
Contact
+/- 
All touchable screws of enclosure
B 2/4 
Contact
+/- 
Accessible metal parts of the EUT
2/4/8 
Air 
+/- 
Air gap of the switch, button 
2/4/8 
Air 
+/- 
The air in-taking opening 
2/4/8 
Air 
+/- 
Slots around the EUT 
 
 
Indirect contact discharges were applied to the VCP and the HCP at the following 
selected points: 
 
 For table top equipment 
Point Description 
Point Result
HCP f  0,1m from the front of the EUT 
Edge of centre,corner on HCP 
Pass 
HCP b  0,1m from the back of the EUT 
Edge of centre,corner on HCP 
Pass 
HCP r  0,1m from the right side of the EUT Edge of centre,corner on HCP 
Pass 
HCP l  0,1m from the left side of the EUT 
Edge of centre,corner on HCP 
Pass 
VCP f  0,1m from the front of the EUT 
Edge of centre,corner on VCP 
Pass 
VCP b  0,1m from the back of the EUT 
Edge of centre,corner on VCP 
Pass 
VCP r  0,1m from the right of the EUT 
Edge of centre,corner on VCP 
Pass 
VCP l  0,1m from the left of the EUT 
Edge of centre,corner on VCP 
Pass 
 
 For floor standing equipment 
Point Description 
Point Result
VCP f  0,1m from the front of the EUT 
Edge of centre,corner on VCP 
VCP b  0,1m from the back of the EUT 
Edge of centre,corner on VCP 
VCP r  0,1m from the right of the EUT 
Edge of centre,corner on VCP 
VCP l  0,1m from the left of the EUT 
Edge of centre,corner on VCP 
 
Observation: The apparatus shall continue to operate as intended after the test.
 
 
Conclusion: The EUT met the requirements of Performance B 
 
Test report no. SH08090332-001 
 
 
Page 61 of 76 
 
16.5 ESD Test point: 
 
 
16.6 Measurement Uncertainty 
 
The measurement uncertainty describes the overall uncertainty of the given measured 
value during the operation of the EUT. 
Measurement uncertainty of ESD test is: 
± 7 % 
The measurement uncertainty is given with a confidence of 95%, k=2. 
The measurement uncertainty is traceable to internal procedure TI-036. 
 
 
16.7 Additions, Deviations and Exclusions from Standards 
 
 
None 
 
Test report no. SH08090332-001 
 
 
Page 62 of 76 
17. Immunity requirements for RF e.m. field Keyed carrier 
 
Test result: 
Pass 
 
17.1 Severity Level and Performance Criterion 
17.1.1 Test level 
 
Frequency 
(MHz) 
Level 
(V/m) 
900 (Duty cycle 1/9, 217Hz repetition 
frequency) 
Note: As an alternative method, a non-homogeneous field strength ≥3 V/m of similar 
characteristics as the test specification (e.g. generated by a dummy GSM portable 
telephone) may be applied in a shielded room. 
The dummy shall be placed on a non-metallic stand with a height of 80 cm, at a 
distance of 1 m to the EUT (see Figure 11). The front side of the EUT shall be 
placed in parallel to the antenna line of sight. The position shall be described in the 
measurement report. 
In case of dispute, measurements shall be carried out in accordance with IEC 
61000-4-3, with measurement conditions given in 5.8.4 and Table 23, and filter B.2 
replaced by B.4. 
 
17.1.2 Performance Criterion   
 
   Performance criterion: A
 
 
 
Test report no. SH08090332-001 
 
 
Page 63 of 76 
17.2 Block diagram of test setup 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
17.3 Test Setup and Test Procedure 
 
Measurement was performed in shielded room. 
Instruments used were following CISPR 16-1 and EN 55020. 
Measurement methods and operation conditions of EUT was according to clause 5.1, 
5.2 and 5.8 of EN55020. 
 
Antenna 
mast 
Power meter
Field monitor 
   
       Table 
Amplifier 
Signal generator 
EUT 
Field probe 
Optical fiber  
AE 
Page of 77
Display