Harman Kardon HD 990 (serv.man5) EMC - CB Certificate ▷ View online
Test report no. SH08090332-001
Page 44 of 76
11. Immunity requirements at mains, loudspeaker and headphone
output connector (S2a)
Test result: Pass
11.1 Limits and Performance Criterion
11.1.1 Limits
11.1.2 Performance Criterion
Performance criterion A
Performance criterion A
11.2 Block Diagram of Test Setup
Test report no. SH08090332-001
Page 45 of 76
11.3 Test Setup and Test Procedure
Measurement was performed in shielded room.
Instruments used were following CISPR 16-1 and EN 55020.
Measurement methods and operation conditions of EUT was according to clause 5.1,
Instruments used were following CISPR 16-1 and EN 55020.
Measurement methods and operation conditions of EUT was according to clause 5.1,
5.2 and 5.7 of EN55020.
11.4 Test Protocol
Temperature
:
22
°C
Relative Humidity:
40%
Mains
11.5 Additions, Deviations and Exclusions from Standards
None
Test report no. SH08090332-001
Page 46 of 76
12. Immunity requirements for audio input and output connectors
(excluding loudspeaker and headphone) (S2a)
Test result: Pass
12.1 Limits and Performance Criterion
12.1.1 Limits
12.1.2 Performance Criterion
Performance criterion A
Performance criterion A
12.2 Block Diagram of Test Setup
Test report no. SH08090332-001
Page 47 of 76
12.3 Test Setup and Test Procedure
Measurement was performed in shielded room.
Instruments used were following CISPR 16-1 and EN 55020.
Measurement methods and operation conditions of EUT was according to clause 5.1,
Instruments used were following CISPR 16-1 and EN 55020.
Measurement methods and operation conditions of EUT was according to clause 5.1,
5.2 and 5.7 of EN55020.
12.4 Test Protocol
Temperature
:
22
°C
Relative Humidity:
40%
AUDIO OUT L terminal:
AUDIO OUT R terminal:
Click on the first or last page to see other HD 990 (serv.man5) service manuals if exist.