Harman Kardon HD 990 (serv.man4) EMC - CB Certificate ▷ View online

 
                                                                                Page 8 of 51                              Report No. SH08090331-002 
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No:  IEC/EN 60065H 
 
       TRF originator Intertek ETL SEMKO SH 
 
ELECTRIC SHOCK HAZARD UNDER NORMAL OPERATING CONDITIONS 
 
9.1 
Testing on the outside 
 
9.1.1 
For voltages >1000 V ac or >1500 V dc complies 
with clause 13.3.1 for basic insulation  
No such high voltage 
N/A 
9.1.1.1 
Touch current measured from terminal devices 
using the network in annex D ..................................: 
U1=1.22Vp  
U2=0.14Vp 
Pass 
 
Discharge not exceeding 45  C 
1 C 
Pass 
 
Energy of discharge not exceeding 350 mJ 
No voltage exceeding 15kV 
N/A 
9.1.1.2 
Test with test finger and test probe 
 
Pass 
9.1.2 
No hazardous live shafts of knobs, handles or 
levers 
 
Pass 
9.1.3 
Ventilation holes and other holes tested by means 
of 4 mm x 100 mm test pin 
No entering. 
N/A 
9.1.4 
Terminal devices tested with 1 mm x 20 mm test 
pin (10 N); test probe D of IEC 61032 
 
Pass 
 
Terminal devices tested with 1 mm x 100 mm 
straight wire (1 N); test probe D of IEC 61032 
 
Pass 
9.1.5 
Pre-set controls tested with 2.5 mm x 100 mm test 
pin (10 N); test probe C of IEC 61032 
No pre-set control 
N/A 
9.1.6 
No shock hazard due to stored charge on 
withdrawal of the mains plug; voltage (V) after 2 s .: 
 
N/A 
 
If C is not greater than 0,1  F no test needed 
0.1
µ
Pass 
9.1.7 
Enclosure sufficiently resistant to external force 
 
Pass 
 
Test probe 11 of IEC 61032 for 10 s (50 N) 
 
Pass 
 
Test hook of fig. 4 for 10 s (20 N) 
 
Pass 
 
30 mm diameter test tool for 5 s (100 or 250 N) .....:  100N 
Pass 
9.2 
No hazard after removing a cover by hand 
Can not be removed by hand 
N/A 
 
 
10 
INSULATION REQUIREMENTS 
 
10.1 
Insulation resistance (M ) at least 2 M  min. after 
surge test for basic and 4 M  min. for reinforced 
insulation ..................................................................: 
 
N/A 
10.2 
Humidity treatment 48 h or 120 h ............................:  48h, 30 , 93%R.H. 
Pass 
10.3 
Insulation resistance and dielectric strength 
(See appended table) 
Pass 
 
 
 
                                                                                Page 9 of 51                              Report No. SH08090331-002 
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No:  IEC/EN 60065H 
 
       TRF originator Intertek ETL SEMKO SH 
 
11 
FAULT CONDITIONS 
 
11.1 
No shock hazard under fault condition 
 
Pass 
11.2 
Heating under fault condition 
(See appended table) 
Pass 
 
No hazard from softening solder 
 
Pass 
11.2.1 
Measurement of temperature rises 
 
Pass 
11.2.2 
Temperature rise of accessible parts 
 
Pass 
11.2.3 
Temperature rise of parts, other than windings, 
providing electrical insulation 
(See appended table) 
Pass 
 
Temperature rise of printed circuit boards (PCB) 
exceeding the limits of table 3 by max. 100 K for 
max. 5 min 
 
N/A 
 
a) Temperature rise of printed circuit boards (PCB) 
to 20.1.3, exceeding the limits of table 3 by not 
more than 100 K for an area not greater than 2 cm² 
 
N/A 
 
b) Temperature rise of printed circuit boards (PCB) 
to 20.1.3 up to 300 K for an area not greater than 
2 cm² for a maximum of 5 min 
 
N/A 
 
Meets all the special conditions if conductors on 
printed circuit boards are interrupted 
 
N/A 
 
Class I protective earthing maintained 
 
N/A 
11.2.4 
Temperature rise of parts acting as a support or 
mechanical barrier 
           
Pass 
11.2.5 
Temperature rise of windings 
(see appended table) 
Pass 
11.2.6 
Temperature rise of parts not subject to the limits 
of 11.2.1 to 11.2.5 
(see appended table) 
Pass 
 
 
12 
MECHANICAL STRENGTH 
 
12.1.1 
Bump test where mass >7 kg 
3.125kg 
N/A 
12.1.2 
Vibration test 
Not carried out, no connection 
which might impair safety can 
become loosen 
Pass 
12.1.3 
Impact hammer test 
0.5J 
Pass 
 
Steel ball test 
2J 
Pass 
12.1.4 
Drop test for portable apparatus where mass < 7 
kg 
 
Pass 
12.1.5 
Thermoplastic enclosures stress relief test 
70
o
C, 7h 
Pass 
12.2 
Fixing of knobs, push buttons, keys and levers 
 
Pass 
 
                                                                                Page 10 of 51                              Report No. SH08090331-002 
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No:  IEC/EN 60065H 
 
       TRF originator Intertek ETL SEMKO SH 
 
12.3 
Remote controls with hazardous live parts 
           
N/A 
12.4 
Drawers (pull test 50 N, 10 s) 
           
Pass 
12.5 
Antenna coaxial sockets providing isolation 
           
N/A 
12.6 
Telescoping or rod antennas construction 
 
N/A 
12.6.1 
Telescoping or rod antennas securement 
 
N/A 
 
 
13 
CLEARANCE AND CREEPAGE DISTANCES 
 
13.1 
Clearances in accordance with 13.3 
 
Pass 
 
Creepage distances in accordance with 13.4 
 
Pass 
13.2 
Determination of operating voltage 
TR1: pin7- pin 13: 280Vrms, 
900Vp 
Pass 
13.3 
Clearances 
(see appended table) 
Pass 
13.3.2 
Circuits conductively connected to the mains 
comply with table 8 and, where applicable, table 9 
 
Pass 
13.3.3 
Circuits not conductively connected to the mains 
comply with table 10 
Such circuits are secondary 
circuit and do not include 
hazardous voltage, no basic, 
supplementary or reinforced 
insulation required. 
N/A 
13.4 
Creepage distances 
(see appended table) 
Pass 
 
Creepage distances greater than table 11 minima             
Pass 
13.5 
Printed boards 
           
N/A 
13.5.1 
Clearances and creepage distances between 
conductors on printed circuit boards, one of which 
may be conductively connected to the mains, as in 
fig. 10 
           
N/A 
13.5.2 
Type B coated printed circuit boards complying with 
IEC 60664-3 (basic insulation only) 
 
N/A 
13.6 
Conductive parts along uncemented joints 
clearances and creepage distances comply with 
13.3 and 13.4 
 
N/A 
 
Conductive parts along reliably cemented joints 
comply with 8.8 
 
N/A 
13.7 
Enclosed, enveloped or hermetically sealed parts: 
not conductively connected to the mains: 
clearances and creepage distances as in table 12 
           
N/A 
13.8 
Parts filled with insulating compound, meeting the 
requirements of 8.8 
           
N/A 
 
                                                                                Page 11 of 51                              Report No. SH08090331-002 
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No:  IEC/EN 60065H 
 
       TRF originator Intertek ETL SEMKO SH 
 
14 
COMPONENTS 
 
14.1 
Resistors 
 
 
a) Resistors between hazardous live parts and 
accessible metal parts 
No such components 
N/A 
 
b) Resistors, other than between hazardous live 
parts and accessible parts 
 
N/A 
 
Resistors separately approved ................................: 
 
N/A 
14.2 
Capacitors and RC units 
 
Pass 
 
Capacitors separately approved 
Yes  
Pass 
14.2.1 
Y capacitors tested to IEC 60384-14, 2
nd
 edition ....:  Y1: CY1, CY2, CY3 
Pass 
14.2.2 
X capacitors tested to IEC 60384-14, 2
nd
 edition ....:  X2: CX1 
Pass 
14.2.3 
Capacitors operating at mains frequency but not 
connected to the mains: tests for X2  ......................: 
No such component 
N/A 
14.2.5 
Capacitors with volume exceeding 1750 mm³, 
where short-circuit current exceeds 0,2 A: 
compliance with IEC60384-1, 4.38 category B or 
better ........................................................................: 
EC1 metal case 
N/A 
 
Capacitors with volume exceeding 1750 mm³, 
mounted closer to a potential ignition source than 
table 5 permits: compliance with IEC 60 384-1, 
4.38 category B or better .........................................: 
EC1 metal case 
N/A 
 
Shielded by a barrier to V-0 or metal  ......................:   
N/A 
14.3 
Inductors and windings 
 
Pass 
 
Comply with IEC 61558-1, IEC 61558-2 
(as relevant) and clause 20.1.4 
 
N/A 
14.3.1 
Transformers and inductors marked with 
manufacturer's name and type  ...............................: 
Switching mode transformer  
TR1: BCK-EC2802 
Pass 
 
Transformers and inductors separately approved ..:  No 
N/A 
14.3.2 
General 
 
Pass 
14.3.3 
Constructional requirements 
 
Pass 
14.3.3.1 
Clearances and creepage distances comply with 
clause 13 
(see appended table) 
Pass 
14.3.3.2 
Transformers meet the constructional 
requirements 
 
Pass 
Page of 52